 |
Original Article
| Minim Invasive Neurosurg 2005; 48: 165-168 DOI: 10.1055/s-2004-830269 |
© Georg Thieme Verlag Stuttgart · New York |
| |
 |
The Value of Micro-Doppler in Stereotactic Brain Biopsy |
| |
| F. Hertel1, W. Feiden2, M. Bettag1 |
1 Department of Neurosurgery, Brüderkrankenhaus, Trier, Germany
2 Department of Neuropathology, Saarland University, Homburg-Saar, Germany |
Abstract
Objective: The aim of this study was to analyse the value of intraoperative micro-Doppler in stereotactic brain biopsy (SBB). So far, only a few studies have reported about the usefulness of micro-Doppler in stereotactic brain biopsy. Methods: Between 1998 and 2003, 155 SBBs were performed in 153 patients with micro-Doppler (81 males, 72 females, mean age: 59 years). All operations were performed using a ZD-frame and a multiplanar computer tomography-guided trajectory planning system (Leibinger SPP®). A 16 MHz micro-Doppler probe (diameter 1 mm, DWL®) was used in all cases to explore the area of biopsy before the tissue probes were taken. Serial biopsies (mean, 6 samples) were taken with the Sedan side-cutting cannula (n = 145) or the small forceps (n = 10). We evaluated the number of intraoperative detectable vessel signals by micro-Doppler, intraoperative bleedings as well as bleedings detected by postoperative CT (which was performed in all cases). We compared our results according to bleeding-related complications with the data of stereotactic biopsy series from the recent literature. Results: A conclusive histopathological diagnosis was achieved in 150/153 patients (98 %). A re-biopsy had to be undertaken in 2 cases. In 98 biopsies (63 %), no vessel could be detected with the micro-Doppler. In the remainder, a signal of arterial vessels was detected in 22 (14 %) and a signal of venous vessels in 35 cases (23 %). Detection of a vessel in the micro-Doppler led to a change of the biopsy site in each case within the same trajectory. Biopsy-related bleedings were detected in 4 cases (2.6 %). Among these, the only bleeding which occurred without any signs of vessels in the micro-Doppler happened in a case of a melanoma. The overall biopsy-related permanent morbidity was 0.6 % (n = 1). The biopsy-related mortality was 0. Conclusions: Despite the overall high security of SBB, the use of intraoperative micro-Doppler may lead to an additional reduction of the risk for a biopsy-related bleeding without enormous expense.
Key words
Stereotactic biopsy - micro-Doppler - bleeding
|  |