J Wrist Surg 2012; 01(02): 159-164
DOI: 10.1055/s-0032-1329591
Scientific Articles
Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

Treatment of Avascular Necrosis of the Proximal Pole of the Scaphoid by Arthroscopic Resection and Prosthetic Semireplacement Arthroplasty Using the Pyrocarbon Adaptive Proximal Scaphoid Implant (APSI): Long-Term Functional Outcomes

Mathilde Gras
1   Institut de l'Appareil Locomoteur Nollet, Paris, France
,
Abhijeet L. Wahegaonkar
2   Upper Extremity, Hand and Microvascular Reconstructive Surgeon, Hand Surgery Associates, Pune, Maharashtra, India
3   Sancheti Institute for Orthopedics and Rehabilitation, Pune, Maharashtra, India
,
Christophe Mathoulin
4   Institut de la Main, Clinique Jouvenet, Paris, France
› Author Affiliations
Further Information

Publication History

Publication Date:
20 December 2012 (online)

Abstract

Fractures of the proximal pole of the scaphoid with associated avascular necrosis and nonunion are well known to be problematic. Many techniques for fixation and reconstruction of the proximal pole of the scaphoid have been reported, often with poor results. One of the newer modalities of treatment for these difficult cases is excision of the proximal pole and replacement with a pyrocarbon implant. The ovoid shape of the implant acts as a spacer and repositions itself throughout the range of motion of the wrist. The procedure can be performed arthroscopically, thus reducing the morbidity and allowing the procedure to be a day case. Satisfactory results have been reported in elderly patients, but there is a paucity of literature regarding the outcomes in younger patients. This multicenter retrospective study evaluates the clinical, radiologic, and functional outcomes in patients under the age of 65 years with a minimum follow up of 5 years. There were 14 patients with scaphoid nonunion advanced collapse (SNAC) grade I, II, or III wrists, with a mean age of 53 years and mean follow up of 8.7 years. There were improvements in all of the patient related variables including VAS pain scores (7.5 to 0.7), extension (45° to 60°), flexion (32° to 53°), and grip strength (15.8 to 34.6 kg). Complications included volar subluxation of the implant, which was acutely surgically corrected (1), volar subluxation of the implant, with persistent pain that required a four-corner fusion (2), and secondary radial styloidectomy (3). This technique is an attractive, minimally invasive alternative for nonunion and avascular necrosis resulting from fractures of the proximal pole of the scaphoid. The authors provide details of the technique, including technical suggestions for performing the procedure.

 
  • References

  • 1 Kakar S, Bishop AT, Shin AY. Role of vascularized bone grafts in the treatment of scaphoid nonunions associated with proximal pole avascular necrosis and carpal collapse. J Hand Surg Am 2011; 36 (4) 722-725 , quiz 725
  • 2 Merrell GA, Wolfe SW, Slade III JF. Treatment of scaphoid nonunions: quantitative meta-analysis of the literature. J Hand Surg Am 2002; 27 (4) 685-691
  • 3 Mathoulin C, Gras M, Roukos S. Vascularized bone grafting from the volar distal radius for carpal bones reconstruction [in French]. Chir Main 2010; 29 (Suppl. 01) S65-S76
  • 4 Tünnerhoff HG, Haussmann P. Partial midcarpal arthrodesis with excision of the scaphoid for the treatment of advanced carpal collapse [in German]. Oper Orthop Traumatol 2005; 17 (3) 233-248
  • 5 Merrell GA, McDermott EM, Weiss AP. Four-corner arthrodesis using a circular plate and distal radius bone grafting: a consecutive case series. J Hand Surg Am 2008; 33 (5) 635-642
  • 6 Ho PC. Arthroscopic partial wrist fusion. Tech Hand Up Extrem Surg 2008; 12 (4) 242-265
  • 7 Buote NJ, McDonald D, Radasch R. Pancarpal and partial carpal arthrodesis. Compend Contin Educ Vet 2009; 31 (4) 180-192
  • 8 Zeplin PH, Kuhfuss I. Midcarpal arthrodesis with cortical bolting chip for treatment of grade II/III scaphoid non-union and scapholunate advanced collapse [in German]. Handchir Mikrochir Plast Chir 2009; 41 (3) 183-185
  • 9 Dimitrios G, Athanasios K, Ageliki K, Spiridon S. Capitolunate arthrodesis maintaining carpal height for the treatment of SNAC wrist. J Hand Surg Eur Vol 2010; 35 (3) 198-201
  • 10 Pequignot JP, Lussiez B, Allieu Y. An adaptive proximal scaphoid implant [in French]. Chir Main 2000; 19 (5) 276-285
  • 11 Mathoulin C. Arthroscopic arthroplasty for proximal pole scaphoid nonunion. In: Geissler WB, , ed. Atlas of the Hand Clinics. Philadelphia, PA: WB Saunders; 2001: 341-358
  • 12 Tian CL, Hetherington VJ, Reed S. A review of pyrolytic carbon: application in bone and joint surgery. J Foot Ankle Surg 1993; 32 (5) 490-498
  • 13 Adams BD, Frykman GK, Taleisnik J. Treatment of scaphoid nonunion with casting and pulsed electromagnetic fields: a study continuation. J Hand Surg Am 1992; 17 (5) 910-914
  • 14 Ruby LK, Stinson J, Belsky MR. The natural history of scaphoid non-union. A review of fifty-five cases. J Bone Joint Surg Am 1985; 67 (3) 428-432
  • 15 Mack GR, Bosse MJ, Gelberman RH, Yu E. The natural history of scaphoid non-union. J Bone Joint Surg Am 1984; 66 (4) 504-509
  • 16 Cooney WP, Linscheid RL, Dobyns JH, Wood MB. Scaphoid nonunion: role of anterior interpositional bone grafts. J Hand Surg Am 1988; 13 (5) 635-650
  • 17 Fernandez DL. Anterior bone grafting and conventional lag screw fixation to treat scaphoid nonunions. J Hand Surg Am 1990; 15 (1) 140-147
  • 18 Nakamura R, Imaeda T, Tsuge S, Watanabe K. Scaphoid non-union with D.I.S.I. deformity. A survey of clinical cases with special reference to ligamentous injury. J Hand Surg [Br] 1991; 16 (2) 156-161
  • 19 Stark A, Broström LA, Svartengren G. Surgical treatment of scaphoid nonunion. Review of the literature and recommendations for treatment. Arch Orthop Trauma Surg 1989; 108 (4) 203-209
  • 20 Vinnars B, Adamsson L, af Ekenstam F, Wadin K, Gerdin B. Patient-rating of long term results of silicone implant arthroplasty of the scaphoid. Scand J Plast Reconstr Surg Hand Surg 2002; 36 (1) 39-45
  • 21 Leslie BM, O'Malley M, Thibodeau AA. A forty-three-year follow-up of a Vitallium scaphoid arthroplasty. J Hand Surg Am 1991; 16 (3) 465-468
  • 22 Orsi R, De Tullio V, Brunelli F. Results 37 years after insertion of an acrylic implant for scaphoid pseudoarthrosis [in French]. Ann Chir Main Memb Super 1995; 14 (4-5) 214-217
  • 23 Barber HM. Acrylic scaphoid prostheses: a long-term follow up. Proc R Soc Med 1974; 67 (10) 1075-1078
  • 24 Swanson AB, de Groot Swanson G, DeHeer DH , et al. Carpal bone titanium implant arthroplasty. 10 years' experience. Clin Orthop Relat Res 1997; (342) 46-58
  • 25 Heatley FW, Allen PR. Glutaraldehyde treated bovine fibrocartilage arthroplasty for the scaphoid: a case history and discussion. Biomaterials 1986; 7 (4) 305-307
  • 26 Kujala S, Raatikainen T, Ryhänen J, Kaarela O, Jalovaara P. Composite implant of native bovine bone morphogenetic protein (BMP) and biocoral in the treatment of scaphoid nonunions—a preliminary study. Scand J Surg 2002; 91 (2) 186-190
  • 27 Garcia-Elias M, Lluch A. Partial excision of scaphoid: is it ever indicated?. Hand Clin 2001; 17 (4) 687-695 , x
  • 28 Haussman P. Long-term results after silicone prosthesis replacement of the proximal pole of the scaphoid bone in advanced scaphoid nonunion. J Hand Surg [Br] 2002; 27 (5) 417-423
  • 29 Peimer CA, Medige J, Eckert BS, Wright JR, Howard CS. Reactive synovitis after silicone arthroplasty. J Hand Surg Am 1986; 11 (5) 624-638
  • 30 Grandis C, Berzero GF. Partial scaphoid pyrocarbon implant: personal series review. J Hand Surg [E] 2007; 32 (Suppl. 01) 95