Semin Thromb Hemost 2017; 43(03): 270-276
DOI: 10.1055/s-0036-1597297
Review Article
Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

Laboratory Monitoring of Parenteral Direct Thrombin Inhibitors

Elizabeth M. Van Cott
1  Department of Pathology GRJ235, Massachusetts General Hospital, Boston, Massachusetts
,
A. Joshua Roberts
2  Department of Pharmacy, University of California Davis Medical Center, Sacramento, California
,
William E. Dager
2  Department of Pharmacy, University of California Davis Medical Center, Sacramento, California
› Institutsangaben
Weitere Informationen

Publikationsverlauf

Publikationsdatum:
04. Januar 2017 (online)

Abstract

Argatroban and bivalirudin are parenteral direct inhibitors of the activity of thrombin, but, unlike heparin, can inhibit both soluble as well as clot-bound thrombin. These agents do not require antithrombin as a cofactor for activity. The parenteral direct thrombin inhibitors (DTIs) can be used in a variety of settings, including heparin-induced thrombocytopenia (HIT) or an allergy to heparin, and patients requiring anticoagulation for an invasive cardiovascular intervention. Both agents have a relatively short half-life in patients without organ system failure and are typically administered by continuous infusion. Argatroban is primarily eliminated by the liver, while bivalirudin is removed by a combination of proteolytic cleavage by thrombin and renal clearance mechanisms. Several laboratory tests are available for monitoring the anticoagulant effects of the DTIs: the activated partial thromboplastin time (aPTT) and the activated clotting time (ACT) are the most commonly used assays, but on occasion, the thrombin time may be useful. Other coagulation assays such as the dilute thrombin time (dTT), chromogenic anti-IIa assays, and the ecarin clotting time (ECT) can be used. The intensity of anticoagulation with DTIs depends on the indication for use. For patients with HIT, the target aPTT is 1.5 to 3.0 and 1.5 to 2.5 times the patient's baseline value for argatroban and bivalirudin, respectively. DTI anticoagulation used during percutaneous coronary intervention can be measured using ACT. Both DTIs may cause an elevation in the international normalized ratio depending on their plasma concentration. This article will review the use of parenteral DTIs and related laboratory assays for assessing the anticoagulant effect of these drugs.