The Impact of Polymerization Technique and Glass-Fiber Reinforcement on the Flexural Properties of Denture Base Resin Material

Ahmad M. Al-Thobity
1   Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
› Author Affiliations

Abstract

Objective Different polymerization and reinforcement techniques have been tested to enhance the mechanical characteristics of denture base acrylic resins. The goal of the present study was to evaluate the influence of autoclave polymerization techniques with glass fiber reinforcement on the flexural strength and elastic modulus of polymethyl methacrylate denture base resins.

Materials and Methods Ninety specimens were fabricated from heat-polymerized acrylic resin and randomly distributed depending on the polymerization technique into three groups (n = 30): water bath polymerization, short-cycle autoclave polymerization, and long-cycle autoclave polymerization. Each group was further divided into three subgroups (n = 10) based on the concentration of glass fiber 0, 2.5, and 5wt%. The flexural strength and elastic modulus were investigated using a universal testing machine. One-way ANOVA and Tukey’s post hoc test were performed to analyze the results (α = 0.05).

Results The flexural strength and elastic modulus values were significantly higher in 5wt% glass fiber reinforced long-cycle autoclave group in comparison with the other test groups (p < 0.05).

Conclusions The long-cycle autoclave polymerization technique with the glass fiber reinforcement significantly increased the flexural strength and elastic modulus of the denture base resin material.



Publication History

Article published online:
13 March 2020

© .

Thieme Medical and Scientific Publishers Private Ltd
A-12, Second Floor, Sector -2, NOIDA -201301, India

 
  • References

  • 1 Narva KK, Lassila LV, Vallittu PK. The static strength and modulus of fiber reinforced denture base polymer. Dent Mater 2005; 21 (05) 421-428
  • 2 Polychronakis N, Yannikakis S, Zissis A. A clinical 5-year longitudinal study on the dimensional changes of complete maxillary dentures. Int J Prosthodont 2003; 16 (01) 78-81
  • 3 Nejatian T, Johnson A, Van Noort R. Reinforcement of denture base resin. Advances in Science and Technology 2006; 49: 124-129
  • 4 Meng Jr TR, Latta MA. Physical properties of four acrylic denture base resins. J Contemp Dent Pract 2005; 6 (04) 93-100
  • 5 Narendra R, Reddy NS, Reddy SD, Purna CR, Shekar MC, Balasubramanyam S. A comparative evaluation of impact strength of conventionally heat cured and high impact heat cured polymethyl methacrylate denture base resins: an in vitro study. J Contemp Dent Pract 2013; 14 (06) 1115-1121
  • 6 Jagger DC, Harrison A, Jandt KD. The reinforcement of dentures. J Oral Rehabil 1999; 26 (03) 185-194
  • 7 Kanie T, Fujii K, Arikawa H, Inoue K. Flexural properties and impact strength of denture base polymer reinforced with woven glass fibers. Dent Mater 2000; 16 (02) 150-158
  • 8 Price CA. The effect of cross-linking agents on the impact resistance of a linear poly(methyl methacrylate) denture-base polymer. J Dent Res 1986; 65 (07) 987-992
  • 9 Winkler S. Denture base resins. Dent Clin North Am 1984; 28 (02) 287-297
  • 10 Ayaz EA, Durkan R, Koroglu A, Bagis B. Comparative effect of different polymerization techniques on residual monomer and hardness properties of PMMA-based denture resins. J Appl Biomater Funct Mater 2014; 12 (03) 228-233
  • 11 Durkan R, Ozel MB, Bağiş B, Usanmaz A. In vitro comparison of autoclave polymerization on the transverse strength of denture base resins. Dent Mater J 2008; 27 (04) 640-642
  • 12 Kasina SP, Ajaz T, Attili S, Surapaneni H, Cherukuri M, Srinath HP. To evaluate and compare the porosities in the acrylic mandibular denture bases processed by two different polymerization techniques, using two different brands of commercially available denture base resins - an in vitro study. J Int Oral Health 2014; 6 (01) 72-77
  • 13 Ozkir SE, Yilmaz B, Unal SM, Culhaoglu A, Kurkcuoglu I. Effect of heat polymerization conditions and microwave on the flexural strength of polymethyl methacrylate. Eur J Dent 2018; 12 (01) 116-119
  • 14 Lai CP, Tsai MH, Chen M, Chang HS, Tay HH. Morphology and properties of denture acrylic resins cured by microwave energy and conventional water bath. Dent Mater 2004; 20 (02) 133-141
  • 15 Frangou MJ, Polyzois GL. Effect of microwave polymerisation on indentation creep, recovery and hardness of acrylic denture base materials. Eur J Prosthodont Restor Dent 1993; 1 (03) 111-115
  • 16 Ruffino AR. Effect of steel strengtheners on fracture resistance of the acrylic resin complete denture base. J Prosthet Dent 1985; 54 (01) 75-78
  • 17 Gad MM, Rahoma A, Al-Thobity AM, ArRejaie AS. Influence of incorporation of ZrO[2] nanoparticles on the repair strength of polymethyl methacrylate denture bases. Int J Nanomedicine 2016; 11: 5633-5643
  • 18 Vallittu PK, Lassila VP. Effect of metal strengthener’s surface roughness on fracture resistance of acrylic denture base material. J Oral Rehabil 1992; 19 (04) 385-391
  • 19 Mowade TK, Dange SP, Thakre MB, Kamble VD. Effect of fiber reinforcement on impact strength of heat polymerized polymethyl methacrylate denture base resin: in vitro study and SEM analysis. J Adv Prosthodont 2012; 4 (01) 30-36
  • 20 Vallittu PK, Vojtkova H, Lassila VP. Impact strength of denture polymethyl methacrylate reinforced with continuous glass fibers or metal wire. Acta Odontol Scand 1995; 53 (06) 392-396
  • 21 Gutteridge DL. The effect of including ultra-high-modulus polyethylene fibre on the impact strength of acrylic resin. Br Dent J 1988; 164 (06) 177-180
  • 22 Vallittu PK. Glass fiber reinforcement in repaired acrylic resin removable dentures: preliminary results of a clinical study. Quintessence Int 1997; 28 (01) 39-44
  • 23 Hamouda IM, Beyari MM. Addition of glass fibers and titanium dioxide nanoparticles to the acrylic resin denture base material: comparative study with the conventional and high impact types. Oral Health Dent Manag 2014; 13 (01) 107-112
  • 24 Ekstrand K, Ruyter IE, Wellendorf H. Carbon/graphite fiber reinforced poly(methyl methacrylate): properties under dry and wet conditions. J Biomed Mater Res 1987; 21 (09) 1065-1080
  • 25 Foo SH, Lindquist TJ, Aquilino SA, Schneider RL, Williamson DL, Boyer DB. Effect of polyaramid fiber reinforcement on the strength of 3 denture base polymethyl methacrylate resins. J Prosthodont 2001; 10 (03) 148-153
  • 26 Fonseca RB, Favarao IN, Kasuya AVB, Abrao M, Luz NFM, Navez LZ. Influence of glass fiber Wt% and silanization on mechanical flexural strength of reinforced acrylic. J of Mat Sci and Chem 2014; 2: 11-15
  • 27 Geerts GA, Overturf JH, Oberholzer TG. The effect of different reinforcements on the fracture toughness of materials for interim restorations. J Prosthet Dent 2008; 99 (06) 461-467
  • 28 John J, Gangadhar SA, Shah I. Flexural strength of heat-polymerized polymethyl methacrylate denture resin reinforced with glass, aramid, or nylon fibers. J Prosthet Dent 2001; 86 (04) 424-427
  • 29 Revised American Dental Association specification no. 12 for denture base polymers. J Am Dent Assoc 1975; 90 (02) 451-458
  • 30 Gad MM, Al-Thobity AM, Rahoma A, Abualsaud R, Al-Harbi FA, Akhtar S. Reinforcement of PMMA denture base material with a mixture of ZrO[2] nanoparticles and glass fibers. Int J Dent 2019; 2019: 2489393
  • 31 International Organization for Standardization. Dentistry-base polymers - Part 1: denture base polymers. (; Volume 20795–1). Geneva: ISO; 2008
  • 32 Chamberland C. Chronological reference marks. Paris: Pasteur Institute; 2007: 1-19
  • 33 Abdulwahhab SS. High-impact strength acrylic denture base material processed by autoclave. J Prosthodont Res 2013; 57 (04) 288-293
  • 34 Farina AP, Cecchin D, Soares RG. et al. Evaluation of Vickers hardness of different types of acrylic denture base resins with and without glass fibre reinforcement. Gerodontology 2012; 29 (02) e155-e160
  • 35 Hayden WJ. Flexural strength of microwave-cured denture baseplates. Gen Dent 1986; 34 (05) 367-371
  • 36 Moreno-Maldonado V, Acosta-Torres LS, Barceló-Santana FH, Vanegas-Lancón RD, Plata-Rodríguez ME, Castaño VM. Fiber-reinforced nanopigmented poly (methyl methacrylate) as improved denture base. J Appl Polym Sci 2012; 126: 289-296
  • 37 Uzun G, Hersek N, Tinçer T. Effect of five woven fiber reinforcements on the impact and transverse strength of a denture base resin. J Prosthet Dent 1999; 81 (05) 616-620
  • 38 Inanaga A, Naka S, Takahashi Y. et al. Studies on denture base resins reinforced with carbon or aramid fiber. Part 1. The effectiveness of including fiber and surface treatments. J Jpn Prosthodont Soc 1993; 37: 1083-1090
  • 39 Shimozato T, Yamanaka A, Kurata S, Yamazaki N. Denture base PMMA resins reinforced with carbon fibers. Part 1. Surface treatments of the carbon fibers and its effects on flexural and tensile strength of the reinforced resins. J Jpn Soc Dent Mater Device 1984; 3: 648-654
  • 40 Nagai E, Otani K, Satoh Y, Suzuki S. Repair of denture base resin using woven metal and glass fiber: effect of methylene chloride pretreatment. J Prosthet Dent 2001; 85 (05) 496-500