CC BY-NC-ND 4.0 · J Neuroanaesth Crit Care 2022; 09(03): 162-167
DOI: 10.1055/s-0042-1750710
Original Article

Radiation Safety for Anesthesiologists and Other Personnel on Simultaneous PET/MRI: Possible Radiation Exposure from Patients While Performing Prolonged Duration Scans

Chandana Nagaraj
1   Department of Neuro Imaging and Interventional Radiology, National Institute of Mental Health and Neuro Sciences, Bengaluru, Karnataka, India
,
Raman K. Joshi
1   Department of Neuro Imaging and Interventional Radiology, National Institute of Mental Health and Neuro Sciences, Bengaluru, Karnataka, India
,
Dinesh Kumar
1   Department of Neuro Imaging and Interventional Radiology, National Institute of Mental Health and Neuro Sciences, Bengaluru, Karnataka, India
,
Gopinath R.
1   Department of Neuro Imaging and Interventional Radiology, National Institute of Mental Health and Neuro Sciences, Bengaluru, Karnataka, India
,
Dhritiman Chakrabarti
2   Department of Neuroanaesthesia and Neurocritical Care, National Institute of Mental Health and Neuro Sciences, Bengaluru, Karnataka, India
,
Pardeep K. Singh
1   Department of Neuro Imaging and Interventional Radiology, National Institute of Mental Health and Neuro Sciences, Bengaluru, Karnataka, India
,
Sandhya Mangalore
1   Department of Neuro Imaging and Interventional Radiology, National Institute of Mental Health and Neuro Sciences, Bengaluru, Karnataka, India
,
Ramesh Venkatapura
2   Department of Neuroanaesthesia and Neurocritical Care, National Institute of Mental Health and Neuro Sciences, Bengaluru, Karnataka, India
› Author Affiliations

Abstract

This observational study was conducted owing to the challenges of the positron emission tomography/magnetic resonance imaging (PET/MRI) that requires longer duration scanning of radiopharmaceutical injected patient and added MRI environment. The aim of this study was to assess radiation dose at different distances from the patient and the radiation burden to anesthesiologist and other personnel in performing PET/MRI under general anesthesia or sedation. First, the pre- and postscan whole body radiation exposure (WBE) from the patient were obtained for 45 minutes (n = 109) after injection of the radiopharmaceutical. The WBE was obtained at specific distances from brain (10, 30, and 100 cm) and abdomen (10 and 30cm) of patients undergoing F18 fluorodeoxyglucose PET/MRI brain or whole body studies. Second, WBE of the anesthesiologist and other staff working was separately measured using pocket dosimeters during the whole procedure. In brain scans, the mean absorbed dose rates (ADR) of prescan (45 minutes) and postscan (45 minutes) were 44.4 and 31.1 μSv at 10 cm, 14.9 and 9.7μSv at 30 cm, and 3.5 and 2.8 μSv at 100 cm, respectively, from surface of head. Similarly, it was 54.8 and 30.3 μSv at 10 cm, 23 and 13.6μSv at 30 cm, respectively, from surface of abdomen. In WB scans, the mean ADR was higher than the brain scans. Anesthesiologist exposure overall was found to be 4.84 µSv/patient/scan (112 patients). The anesthesiologist receives a safe mean effective dose in PET/MRI scanning. With good training and adequate planning, it is possible to decrease the radiation exposure to all the concerned personnel including anesthesiologists.



Publication History

Article published online:
20 January 2023

© 2022. Indian Society of Neuroanaesthesiology and Critical Care. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/)

Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India

 
  • References

  • 1 Musafargani S, Ghosh KK, Mishra S, Mahalakshmi P, Padmanabhan P, Gulyás B. PET/MRI: a frontier in era of complementary hybrid imaging. Eur J Hybrid Imaging 2018; 2 (01) 12
  • 2 Barbosa FdeG, von Schulthess G, Veit-Haibach P. Workflow in simultaneous PET/MRI. Semin Nucl Med 2015; 45 (04) 332-344
  • 3 ICRP. The 2007 Recommendations of the International Commission on Radiological Protection. ICRP Publication 103. Ann ICRP 2007; 37 (2-4) 1-332
  • 4 Madsen MT, Anderson JA, Halama JR. et al. AAPM Task Group 108: PET and PET/CT shielding requirements. Med Phys 2006; 33 (01) 4-15
  • 5 Laaksonen L, Kallioinen M, Långsjö J. et al. Comparative effects of dexmedetomidine, propofol, sevoflurane, and S-ketamine on regional cerebral glucose metabolism in humans: a positron emission tomography study. Br J Anaesth 2018; 121 (01) 281-290
  • 6 Demir M, Demir B, Yaşar D. et al. Radiation doses to technologists working with 18F‐FDG in a PET center with high patient capacity. Nukleonika 2010; 55: 107-112
  • 7 Seierstad T, Stranden E, Bjering K. et al. Doses to nuclear technicians in a dedicated PET/CT centre utilising 18F fluorodeoxyglucose (FDG). Radiat Prot Dosimetry 2007; 123 (02) 246-249
  • 8 Donmoon T, Chamroonrat W, Tuntawiroon M. Radiation exposure to nuclear medicine staffs during 18F‐FDG PET/ CT procedures at Ramathibodi Hospital. J Phys Conf Ser 2016; 694: 012061
  • 9 Harbottle EA, Parker RP, Davis R. Radiation doses to staff in a department of nuclear medicine. Br J Radiol 1976; 49 (583): 612-617
  • 10 Guillet B, Quentin P, Waultier S, Bourrelly M, Pisano P, Mundler O. Technologist radiation exposure in routine clinical practice with 18F-FDG PET. J Nucl Med Technol 2005; 33 (03) 175-179
  • 11 Linemann H, Will E, Beuthien-Baumann B. [Investigations of radiation exposure of the medical personnel during F-18-FDG PET studies]. Nucl Med (Stuttg) 2000; 39 (03) 77-81
  • 12 Benatar NA, Cronin BF, O'Doherty MJ. Radiation dose rates from patients undergoing PET: implications for technologists and waiting areas. Eur J Nucl Med 2000; 27 (05) 583-589
  • 13 Jha AK, Singh AM, Mithun S. et al. Designing of high-volume PET/CT facility with optimal reduction of radiation exposure to the staff: implementation and optimization in a tertiary health care facility in India. World J Nucl Med 2015; 14 (03) 189-196
  • 14 Pant GS, Senthamizhchelvan S. Radiation exposure to staff in a PET/CT facility. Indian J Nucl Med 2006; 21: 100-103
  • 15 Siddiqui SS, Jha A, Konar N, Ranganathan P, Deshpande DD, Divatia JV. Radiation exposure among medical professionals working in the intensive care unit. Indian J Crit Care Med 2014; 18 (09) 591-595