Rofo 2017; 189(11): 1047-1054
DOI: 10.1055/s-0043-112336
Interventional Radiology
© Georg Thieme Verlag KG Stuttgart · New York

White Paper: Interventional MRI: Current Status and Potential for Development Considering Economic Perspectives, Part 2: Liver and Other Applications in Oncology

Artikel in mehreren Sprachen: English | deutsch
Jörg Barkhausen
1   Department of Radiology and Nuclear Medicine, University Hospital Schleswig Holstein Luebeck Campus, Germany
,
Thomas Kahn
2   Clinic and Policlinic for Diagnostic and Interventional Radiology, Leipzig, Germany
,
Gabriele A. Krombach
3   Department of Radiology, University Hospital Giessen, Justus Liebig University, Giessen, Germany
,
Christiane K. Kuhl
4   Department of Diagnostic and Interventional Radiology, University Hospital RWTH Aachen, Germany
,
Joachim Lotz
5   Institute for Diagnostic and Interventional Radiology, Georg-August-University Goettingen, Germany
,
David Maintz
6   Department of Radiology, University Hospital of Cologne, Cologne, Germany
,
Jens Ricke
7   Department of Radiology and Nuclear Medicine, University Hospital Magdeburg, Germany
,
Stefan O. Schönberg
8   Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, University of Heidelberg, Mannheim, Germany
,
Thomas J. Vogl
9   Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Germany
,
Frank K. Wacker
10   Department for Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany
,
German Association of Chairmen in Academic Radiology (KLR)
› Institutsangaben
Weitere Informationen

Publikationsverlauf

15. Februar 2017

08. Mai 2017

Publikationsdatum:
01. September 2017 (online)

Abstract

Background MRI is attractive for guiding and monitoring interventional procedures due to its high intrinsic soft tissue contrast and the possibility to measure flow and cardiac function.

Methods Technical solutions have been developed for all procedural steps including imaging guidance, MR-safe catheters and instruments and patient monitoring. This has led to widening of the clinical applications. Interventional MRI is becoming increasingly important for the treatment of patients suffering from malignant diseases. The detectability of masses and consequently their accessibility for biopsy is higher, compared to other modalities, due to the high intrinsic soft tissue contrast of MRI. Temperature-dependent sequences allow for minimally invasive and tissue-sparing ablation (A-0 ablation).

Conclusion Interventional MRI has become established in the clinical routine for a variety of indications, including biopsies and tumor ablation. Since the economic requirement of covering costs by reimbursement is met and interventional MRI decreases the mortality and morbidity of interventional procedures, broader application of interventional MRI can be expected in the clinical routine in the future.

Key points

  • Particularly for the treatment of oncological patients, interventional MRI is superior to other methods with respect to minimal invasiveness and tissue protection due to the ability to exactly determine tumor borders and to visualize and control the size of the ablation area on the basis of MR temperature measurement.

  • Due to the better visualization of targets and the effects of ablation in tissue, interventional MRI can lower the mortality and morbidity associated with these interventions for many indications.

  • The complex comparison of costs and reimbursement shows that this application can be performed in a cost-covering manner and broader application can be expected in the future.

Citation Format

  • Barkhausen J, Kahn T, Krombach GA et al. White Paper: Interventional MRI: Current Status and Potential for Development Considering Economic Perspectives, Part 2: Liver and Other Applications in Oncology. Fortschr Röntgenstr 2017; 189: 1047 – 1054

 
  • References

  • 1 Barkhausen J, Kahn T, Krombach GA. et al. White paper: Interventionelle MRT: Status Quo und Entwicklungspotenzial unter ökonomischen Perspektiven, Teil 1: generelle Anwendungen. Fortschr Röntgenstr 2017; 189: 611-623 doi: 10.1055/s-0043-110011
  • 2 Weiss CR, Nour SG, Lewin JS. MR-guided biopsy: a review of current techniques and applications. J Magn Reson Imaging 2008; 27: 311-325
  • 3 Siegmann-Luz KC, Bahrs SD, Preibsch H. et al. Management of breast lesions detectable only on MRI. Fortschr Röntgenstr 2014; 186: 30-36
  • 4 Fischbach F, Bunke J, Thormann M. et al. MR-guided freehand biopsy of liver lesions with fast continuous imaging using a 1.0-T open MRI scanner: experience in 50 patients. Cardiovasc Intervent Radiol 2011; 34: 188-192
  • 5 Schwab SA, Kuefner MA, Adamietz B. et al. MRI-guided core biopsy of the prostate in the supine position – introduction of a simplified technique using large-bore magnet systems. Eur Radiol 2013; 23: 1415-1419
  • 6 Kuhn JP, Langner S, Hegenscheid K. et al. Magnetic resonance-guided upper abdominal biopsies in a high-field wide-bore 3-T MRI system: feasibility, handling, and needle artefacts. Eur Radiol 2010; 20: 2414-2421
  • 7 Zangos S, Eichler K, Wetter A. et al. MR-guided biopsies of lesions in the retroperitoneal space: technique and results. Eur Radiol 2006; 16: 307-312
  • 8 Stattaus J, Maderwald S, Baba HA. et al. MR-guided liver biopsy within a short, wide-bore 1.5 Tesla MR system. Eur Radiol 2008; 18: 2865-2873
  • 9 Xu D, Herzka DA, Gilson WD. et al. MR-guided sclerotherapy of low-flow vascular malformations using T2 -weighted interrupted bSSFP (T2 W-iSSFP): comparison of pulse sequences for visualization and needle guidance. J Magn Reson Imaging 2015; 41: 525-535
  • 10 Boll DT, Merkle EM, Lewin JS. MR-guided percutaneous sclerotherapy of low-flow vascular malformations in the head and neck. Magn Reson Imaging Clin N Am 2005; 13: 595-600
  • 11 Fritz J, Tzaribachev N, Thomas C. et al. Evaluation of MR imaging guided steroid injection of the sacroiliac joints for the treatment of children with refractory enthesitis-related arthritis. Eur Radiol 2011; 21: 1050-1057
  • 12 Streitparth F, Walter T, Wonneberger U. et al. Image-guided spinal injection procedures in open high-field MRI with vertical field orientation: feasibility and technical features. Eur Radiol 2010; 20: 395-403
  • 13 Fritz J, Thomas C, Clasen S. et al. Freehand real-time MRI-guided lumbar spinal injection procedures at 1.5 T: feasibility, accuracy, and safety. Am J Roentgenol 2009; 192: W161-W167
  • 14 Wacker FK, Faiss S, Reither K. et al. MR imaging-guided biliary drainage in an open low-field system: first clinical experiences. Fortschr Röntgenstr 2000; 172: 744-747
  • 15 Porsch M, Wendler JJ, Fischbach F. et al. Placement of percutaneous nephrostomy by open magnetic resonance imaging: clinical results and current status in urology. Urologe A 2012; 51: 1722-1727
  • 16 Rempp H, Waibel L, Hoffmann R. et al. MR-guided radiofrequency ablation using a wide-bore 1.5-T MR system: clinical results of 213 treated liver lesions. Eur Radiol 2012; 22: 1972-1982
  • 17 Ritz JP, Lehmann KS, Zurbuchen U. et al. Improving laser-induced thermotherapy of liver metastases--effects of arterial microembolization and complete blood flow occlusion. Eur J Surg Oncol 2007; 33: 608-615
  • 18 Zangos S, Melzer A, Eichler K. et al. MR-compatible assistance system for biopsy in a high-field-strength system: initial results in patients with suspicious prostate lesions. Radiology 2011; 259: 903-910
  • 19 Christoforou EG, Seimenis I, Andreou E. et al. A novel, general-purpose, MR-compatible, manually actuated robotic manipulation system for minimally invasive interventions under direct MRI guidance. Int J Med Robot 2014; 10: 22-34
  • 20 Schell B, Eichler K, Mack MG. et al. Robot-assisted biopsies in a high-field MRI system – first clinical results. Fortwschr Röntgenstr 2012; 184: 42-47
  • 21 Wacker FK, Vogt S, Khamene A. et al. An augmented reality system for MR image-guided needle biopsy: initial results in a swine model. Radiology 2006; 238: 497-504
  • 22 Fritz J, Thainual P, Ungi T. et al. Augmented reality visualization using image overlay technology for MR-guided interventions: cadaveric bone biopsy at 1.5 T. Invest Radiol 2013; 48: 464-470
  • 23 Fischer GS, Deguet A, Csoma C. et al. MRI image overlay: application to arthrography needle insertion. Comput Aided Surg 2007; 12: 2-14
  • 24 Boss A, Rempp H, Martirosian P. et al. Wide-bore 1.5 Tesla MR imagers for guidance and monitoring of radiofrequency ablation of renal cell carcinoma: initial experience on feasibility. Eur Radiol 2008; 18: 1449-1455
  • 25 Zangos S, Vetter T, Huebner F. et al. MR-guided biopsies with a newly designed cordless coil in an open low-field system: initial findings. Eur Radiol 2006; 16: 2044-2050
  • 26 Stattaus J, Maderwald S, Forsting M. et al. MR-guided core biopsy with MR fluoroscopy using a short, wide-bore 1.5-Tesla scanner: feasibility and initial results. J Magn Reson Imaging 2008; 27: 1181-1187
  • 27 Rothgang E, Gilson WD, Wacker F. et al. Rapid freehand MR-guided percutaneous needle interventions: an image-based approach to improve workflow and feasibility. J Magn Reson Imaging 2013; 37: 1202-1212
  • 28 Meyer BC, Brost A, Kraitchman DL. et al. Percutaneous punctures with MR imaging guidance: comparison between MR imaging-enhanced fluoroscopic guidance and real-time MR Imaging guidance. Radiology 2013; 266: 912-919
  • 29 Vogl TJ, Farshid P, Naguib NN. et al. Thermal ablation of liver metastases from colorectal cancer: radiofrequency, microwave and laser ablation therapies. Radiol Med 2014; 119: 451-461
  • 30 Vogl TJ, Farshid P, Naguib NN. et al. Thermal ablation therapies in patients with breast cancer liver metastases: a review. Eur Radiol 2013; 23: 797-804
  • 31 Vogl TJ, Straub R, Zangos S. et al. MR-guided laser-induced thermotherapy (LITT) of liver tumours: experimental and clinical data. Int J Hyperthermia 2004; 20: 713-724
  • 32 Vogl TJ, Straub R, Lehnert T. et al. Percutaneous thermoablation of pulmonary metastases. Experience with the application of laser-induced thermotherapy (LITT) and radiofrequency ablation (RFA), and a literature review. Fortschr Röntgenstr 2004; 176: 1658-1666
  • 33 Morikawa S, Naka S, Murakami K. et al. Preliminary clinical experiences of a motorized manipulator for magnetic resonance image-guided microwave coagulation therapy of liver tumors. Am J Surg 2009; 198: 340-347
  • 34 Morrison PR, Silverman SG, Tuncali K. et al. MRI-guided cryotherapy. J Magn Reson Imaging 2008; 27: 410-420
  • 35 Morikawa S, Naka s, Murayama H. et al. MRI-Guided Microwave Ablation. Medical Radiology 2012; 389-402
  • 36 Kickhefel A, Roland J, Weiss C. et al. Accuracy of real-time MR temperature mapping in the brain: a comparison of fast sequences. Phys Med 2010; 26: 192-201
  • 37 Bazrafshan B, Hubner F, Farshid P. et al. Magnetic resonance temperature imaging of laser-induced thermotherapy: assessment of fast sequences in ex vivo porcine liver. Future Oncol 2013; 9: 1039-1050
  • 38 Kickhefel A, Rosenberg C, Roland J. et al. A pilot study for clinical feasibility of the near-harmonic 2D referenceless PRFS thermometry in liver under free breathing using MR-guided LITT ablation data. Int J Hyperthermia 2012; 28: 250-266
  • 39 Valerio M, Ahmed HU, Emberton M. et al. The role of focal therapy in the management of localised prostate cancer: a systematic review. Eur Urol 2014; 66: 732-751
  • 40 Raz O, Haider MA, Davidson SR. et al. Real-time magnetic resonance imaging-guided focal laser therapy in patients with low-risk prostate cancer. Eur Urol 2010; 58: 173-177
  • 41 Lindner U, Ghai S, Spensieri P. et al. Focal magnetic resonance guided focused ultrasound for prostate cancer: Initial North American experience. Can Urol Assoc J 2012; 6: E283-E286
  • 42 Napoli A, Anzidei M, De NC. et al. Real-time magnetic resonance-guided high-intensity focused ultrasound focal therapy for localised prostate cancer: preliminary experience. Eur Urol 2013; 63: 395-398
  • 43 Chopra R, Colquhoun A, Burtnyk M. et al. MR imaging-controlled transurethral ultrasound therapy for conformal treatment of prostate tissue: initial feasibility in humans. Radiology 2012; 265: 303-313
  • 44 Gangi A, Tsoumakidou G, Abdelli O. et al. Percutaneous MR-guided cryoablation of prostate cancer: initial experience. Eur Radiol 2012; 22: 1829-1835
  • 45 Oto A, Sethi I, Karczmar G. et al. MR imaging-guided focal laser ablation for prostate cancer: phase I trial. Radiology 2013; 267: 932-940
  • 46 Ghai S, Trachtenberg J. In-bore MRI interventions: current status and future applications. Curr Opin Urol 2015; 25: 205-211
  • 47 Woodrum DA, Kawashima A, Karnes RJ. et al. Magnetic resonance imaging-guided cryoablation of recurrent prostate cancer after radical prostatectomy: initial single institution experience. Urology 2013; 82: 870-875
  • 48 Bomers JG, Yakar D, Overduin CG. et al. MR imaging-guided focal cryoablation in patients with recurrent prostate cancer. Radiology 2013; 268: 451-460
  • 49 Cepek J, Lindner U, Ghai S. et al. Mechatronic system for in-bore MRI-guided insertion of needles to the prostate: An in vivo needle guidance accuracy study. J Magn Reson Imaging 2015; 42: 48-55 doi: 10.1002/jmri.24742
  • 50 Phenix CP, Togtema M, Pichardo S. et al. High intensity focused ultrasound technology, its scope and applications in therapy and drug delivery. J Pharm Pharm Sci 2014; 17: 136-153
  • 51 Ruhnke H, Eckey T, Bohlmann MK. et al. MR-guided HIFU treatment of symptomatic uterine fibroids using novel feedback-regulated volumetric ablation: effectiveness and clinical practice. Fortschr Röntgenstr 2013; 185: 983-991
  • 52 Kim YS, Trillaud H, Rhim H. et al. MR thermometry analysis of sonication accuracy and safety margin of volumetric MR imaging-guided high-intensity focused ultrasound ablation of symptomatic uterine fibroids. Radiology 2012; 265: 627-637
  • 53 Trumm CG, Stahl R, Clevert DA. et al. Magnetic resonance imaging-guided focused ultrasound treatment of symptomatic uterine fibroids: impact of technology advancement on ablation volumes in 115 patients. Invest Radiol 2013; 48: 359-365
  • 54 Gorny KR, Woodrum DA, Brown DL. et al. Magnetic resonance-guided focused ultrasound of uterine leiomyomas: review of a 12-month outcome of 130 clinical patients. J Vasc Interv Radiol 2011; 22: 857-864
  • 55 Geiger D, Napoli A, Conchiglia A. et al. MR-guided focused ultrasound (MRgFUS) ablation for the treatment of nonspinal osteoid osteoma: a prospective multicenter evaluation. J Bone Joint Surg Am 2014; 96: 743-751
  • 56 Malietzis G, Monzon L, Hand J. et al. High-intensity focused ultrasound: advances in technology and experimental trials support enhanced utility of focused ultrasound surgery in oncology. Br J Radiol 2013; 86: 20130044
  • 57 Huisman M, Ter HG, Napoli A. et al. International consensus on use of focused ultrasound for painful bone metastases: Current status and future directions. Int J Hyperthermia 2015; 1-9