Endoscopy 2017; 49(10): E240-E241
DOI: 10.1055/s-0043-114406
E-Videos
© Georg Thieme Verlag KG Stuttgart · New York

Endoscopic removal of migrated colonic self-expandable metallic stent using a sliding tube

Rintaro Moroi
1   Division of Gastroenterology, Department of Internal Medicine, Tohoku University Graduate School of Medicine, Sendai, Japan
2   Department of Gastroenterology, Iwate Prefectural Isawa Hospital, Iwate, Japan
,
Yoichi Kakuta
1   Division of Gastroenterology, Department of Internal Medicine, Tohoku University Graduate School of Medicine, Sendai, Japan
,
Katsuya Endo
1   Division of Gastroenterology, Department of Internal Medicine, Tohoku University Graduate School of Medicine, Sendai, Japan
3   Division of Gastroenterology and Hepatology, Tohoku Medical and Pharmaceutical University, Sendai, Japan
,
Masatake Kuroha
1   Division of Gastroenterology, Department of Internal Medicine, Tohoku University Graduate School of Medicine, Sendai, Japan
,
Shoichi Kayaba
2   Department of Gastroenterology, Iwate Prefectural Isawa Hospital, Iwate, Japan
,
Yoshitaka Kinouchi
1   Division of Gastroenterology, Department of Internal Medicine, Tohoku University Graduate School of Medicine, Sendai, Japan
,
Tooru Shimosegawa
1   Division of Gastroenterology, Department of Internal Medicine, Tohoku University Graduate School of Medicine, Sendai, Japan
› Author Affiliations
Further Information

Publication History

Publication Date:
18 July 2017 (online)

Self-expandable metallic stents (SEMSs) are widely used in cases of malignant colorectal obstruction, as a bridge to surgery or for palliation. The migration rate of these SEMSs is reportedly 5 % – 10 % [1] [2]. Although the rate is not very high, nevertheless this complication can occur. In cases of placement as a bridge to surgery, the migrated SEMSs can be removed during the subsequent operation. However, if the SEMS had been placed for palliation, migration can have negative effects (e. g., fecal impaction or perforation) on the clinical course. Therefore, endoscopic removal is necessary in such cases.

A 70-year-old man complaining of abdominal fullness was referred to our hospital with obstructive rectal cancer and multiple liver metastases ([Fig. 1 a, b]). Although insertion of a SEMS (Niti-S; 22 × 80 mm; TaeWoong Medical, Seoul, Korea) was attempted for palliation, the stent migrated to the oral side of the tumor. A second SEMS (Niti-S; 22 × 80 mm) was immediately and correctly inserted. Expansion of the second SEMS was confirmed 4 days later and removal of the first migrated SEMS was attempted.

Zoom Image
Fig. 1 a Obstructive rectal cancer, and b multiple liver metastases in a 70-year-old man.

Neither the shape nor external diameter of the migrated stent changed even when it was captured with a snare ([Fig. 2]) and therefore, it could not be removed through the second SEMS. A sliding overtube was prepared as for single-balloon enteroscopy; however it was cut to a length of 80 cm, and the balloon was removed ([Fig. 3]). The migrated SEMS was successfully removed through the sliding overtube ([Video 1], [Fig. 4]). The postoperative course was uneventful, and the patient was discharged.

Zoom Image
Fig. 2 A Niti-S self-expandable metallic stent (SEMS).
Zoom Image
Fig. 3 The sliding overtube was cut to a length of 80 cm and its balloon was removed.

Video 1 Removal of a migrated colonic self-expandable metallic stent (SEMS) through a second stent, using a sliding overtube, in a 70-year-old man with obstructive rectal cancer.


Quality:
Zoom Image
Fig. 4 Removal of the migrated SEMS using a sliding overtube.

Endoscopic removal of the migrated SEMS through the tumor or the second SEMS would have been very difficult and dangerous because the first SEMS did not change its overall shape or diameter even when captured with a snare. However using the sliding overtube the migrated SEMS was safely removed through the tumor and second implanted SEMS.

Endoscopy_UCTN_Code_TTT_1AQ_2AF

Endoscopy E-Videos
https://eref.thieme.de/e-videos

Endoscopy E-Videos is a free access online section, reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high quality video and all contributions are freely accessible online.
This section has its own submission website at https://mc.manuscriptcentral.com/e-videos

 
  • References

  • 1 Khot UP, Lang AW, Murali K. et al. Systematic review of the efficacy and safety of colorectal stents. Br J Surg 2002; 89: 1096-1102 DOI: 10.1046/j.1365-2168.2002.02148.x
  • 2 Small AJ, Coelho-Prabhu N, Baron TH. Endoscopic placement of self-expandable metal stents for malignant colonic obstruction: long-term outcomes and complication factors. Gastrointest Endosc 2010; 71: 560-572 DOI: 10.1016/j.gie.2009.10.012