Abstract
Background: Clinical performance of bioprostheses (BP) with presence of atrial fibrillation and/or
paced rhythm and mechanical prostheses (MP) in aortic valve replacement was considered
a study of importance. Methods: Aortic valve replacement (AVR) was performed in 163 replacements with porcine bioprostheses
(Carpentier-Edwards supra-annular) with atrial fibrillation/paced rhythm identified
at latest follow-up. Mechanical population was 886 procedures (St. Jude Medical =
436; CarboMedics = 450). Concomitant coronary artery bypass (CAB) was conducted in
40.5 % (66) of BP; 27.0 % (239) of MP. MP patients were all (100 %) on Coumadin and
BP patients 35.6 % on acetylsalicylic acid (ASA), 37.4 % Coumadin, 7.4 % Coumadin
+ ASA, and 19.6 % on no therapy. Results: Major thromboembolism (TE) and hemorrhage (ATH) occurred in 2.4 %/pt-yr (32) for
BP and 5.3 %/pt-yr (157) for MP (p < 0.0001); (TE major 1.6 %/pt-yr [21] for BP and 2.1 %/pt-yr [62] for MP [p = 0.24]; ATH = 0.8 %/pt-yr [11] for BP and 3.2 %/pt-yr [95] for MP) (p < 0.0001). There were no predictors of overall TE, TE major, ATH, overall TE + ATH,
and TE major + ATH. Age and CAB were predictors of survival. Overall BP survival at
8 years was 97.5 ± 1.5 %; and for MP 66.4 ± 4.8 % (p < 0.01). Actuarial freedom from overall thromboembolism and hemorrhage was 54.5 ±
10.8 % for MP; 85.9 ± 3.1 % for BP (p = 0.0000). For major thromboembolism and hemorrhage, actuarial freedom was 63.4 ±
11.8 % for MP; 91.4 ± 2.5 % for BP (p = 0.0003). Conclusions: Patients with atrial fibrillation/paced rhythm having AVR with bioprostheses with
45 % on Coumadin have greater freedom from thromboembolism and hemorrhage than after
AVR with mechanical prostheses on Coumadin.
Key words
Atrial fibrillation - paced rhythm - aortic valve replacement
References
- 1
Jamieson W RE, Rosado L J, Munro A I. et al .
Carpentier-Edwards standard porcine bioprosthesis: primary tissue failure (structural
valve deterioration) by age groups.
Ann of Thorac Surg.
1988;
46
155-162
- 2
Jamieson W RE, Tyers G F, Janusz M T. et al .
Age as a determinant for selection of porcine bioprostheses for cardiac valve replacement:
experience with Carpentier-Edwards standard bioprosthesis.
Can J of Cardio.
1991;
7
181-188
- 3
Burr L H, Jamieson W RE, Munro A I, Miyagishima R T, Germann E.
Porcine bioprostheses in the elderly: clinical performance by age groups and valve
positions.
Ann of Thorac Surg.
1995;
60 (Suppl 2)
S264-269
- 4
Jamieson W RE, Burr L H, Miyagishima R T, Germann E, Anderson W N.
Actuarial versus actual freedom from structural valve deterioration with Carpentier-Edwards
porcine bioprostheses.
Can J of Cardio.
1999;
15
973-978
- 5
Edmunds Jr L H, Clark R E, Cohn L H, Grunkemeier G L, Miller D C, Weisel R D.
Guidelines for reporting morbidity and mortality after cardiac valvular operations.
Ann of Thorac Surg.
1996;
62
932-935
- 6
Jamieson W RE, Miyagishima R T, Grunkemeier G L. et al .
Bileaflet mechanical prostheses for aortic valve replacement in patients younger than
65 years and 65 years of age or older: major thromboembolic and hemorrhage complications.
Can J of Surg.
1999;
42
27-36
1 Submission - The Thoracic and Cardiovascular Surgeon Presentation - International
Symposium Cardiac Bioprostheses 2000
MD W. R. Eric Jamieson
486 Burrard Building
St. Paul's Hospital
1081 Burrard Street
Vancouver, BC
Canada V6Z 1Y6
Phone: + 6048068383
Fax: + 60 48 06 83 84
Email: wrej@interchange.ubc.ca