Background and study aims: Population-based screening for colorectal cancer is widely recommended, with conventional
colonoscopy considered to be the preferred diagnostic modality. However, compliance
with screening colonoscopy is low and manpower capacity is limited. Capsule endoscopy
might therefore represent a desirable alternative strategy.
Patients and methods: The PillCam Colon capsule endoscope was prospectively tested in a multicenter setting.
The indications for endoscopy in the enrolled patients included colorectal cancer
screening (43 %), postpolypectomy surveillance (26 %), and lower gastrointestinal
signs and symptoms (31 %). Study subjects underwent colon preparation and then ingested
the capsule on the morning of the examination, with conventional colonoscopy being
performed the same day. The PillCam Colon capsule findings were reviewed by three
experts in capsule endoscopy who were blinded to the conventional colonoscopy findings.
Results: A total of 91 subjects were enrolled in three Israeli centers (55 men, 36 women;
mean age 57), and the results were evaluable in 84 cases. The capsule was excreted
within 10 hours in 74 % of the patients and reached the rectosigmoid colon in the
other 16 %. Of the 84 evaluable patients, 20 (24 %) had significant findings, defined
as at least one polyp of 6 mm or more in size or three or more polyps of any size:
14/20 (70 %) were identified with the capsule and 16/20 (80 %) were identified by
conventional colonoscopy. Polyps of any size were found in 45 patients, 34/45 (76
%) found by the capsule and 36/45 (80 %) by conventional colonoscopy. In comparison
with conventional colonoscopy, false-positive findings on PillCam Colon capsule examination
were recorded in 15/45 cases (33 %). There were no adverse events related to the capsule
endoscopy.
Conclusions: PillCam Colon capsule endoscopy appears to be a promising new modality for colonic
evaluation. Further improvements in the procedure will probably increase capsule examination
completion and polyp detection rates. Additional studies are needed to evaluate the
accuracy of PillCam Colon endoscopy in other patient populations with different prevalence
levels of colonic disease.
References
1
Burnand B, Harris J K, Wietlisbach V. et al .
Use, appropriateness, and diagnostic yield of screening colonoscopy: an international
observational study (EPAGE).
Gastrointest Endosc.
2006;
63
1018-1026
2
Rex D K, Johnson D A, Lieberman D A. et al .
Colorectal cancer prevention 2000: screening recommendations of the American College
of Gastroenterology.
Am J Gastroenterol.
2000;
95
868-877
3
Smith R A, von Eschenbach A C, Wender R. et al .
American Cancer Society guidelines for the early detection of cancer: update of early
detection guidelines for prostate, colorectal, and endometrial cancers.
CA Cancer J Clin.
2001;
51
38-75
4
US Preventive Services Task Force .
Screening for colorectal cancer: recommendation and rationale.
Ann Intern Med.
2002;
137
129-131
5
Winawer S, Fletcher R, Rex D. et al .
Colorectal cancer screening and surveillance: clinical guidelines and rationale -
update based on new evidence.
Gastroenterology.
2003;
124
544-560
6
Cotton P B, Durkalski V L, Pineau B C. et al .
Computed tomographic colonography (virtual colonoscopy): a multi-center comparison
with standard colonoscopy for detection of colorectal neoplasia.
JAMA.
2004;
291
1713-1719
7
Nadel M R, Blackman D K, Shapiro J A, Seeff L C.
Are people being screened for colorectal cancer as recommended? Results from the National
Health Interview Survey.
Prev Med.
2002;
35
199-206
8
Harewood G C, Wiersema M J, Melton L J.
A prospective, controlled assessment of factors influencing acceptance of screening
colonoscopy.
Am J Gastroenterol.
2002;
97
3186-3194
9
Janz N K, Wren P A, Schottenfeld D, Guire K E.
Colorectal cancer screening attitudes and behavior: a population-based study.
Prev Med.
2003;
37
627-634
10
Rex D K, Cutler C S, Lemmel G T. et al .
Colonoscopic miss rates of adenomas determined by back-to-back colonoscopies.
Gastroenterology.
1997;
112
24-28
11
van Rijn J C, Reitsma J B, Stoker J. et al .
Polyp miss rate determined by tandem colonoscopy: a systematic review.
Am J Gastroenterol.
2006;
101
343-350
12
Bensen S, Mott L A, Dain B. et al .
The colonoscopic miss rate and true one-year recurrence of colorectal neoplastic polyps.
Polyp Prevention Study Group.
Am J Gastroenterol.
1999;
94
194-199
13
Pickhardt P J, Nugent P A, Mysliwiec P A. et al .
Location of adenomas missed by optical colonoscopy.
Ann Intern Med.
2004;
141
352-359
14
Gralnek I M, Rabinovitz R, Afik D, Eliakim R.
A simplified ingestion procedure for esophageal capsule endoscopy: initial evaluation
in healthy volunteers.
Endoscopy.
2006;
38
917-922
15
Rex D K, Rahmani E Y, Haseman J H. et al .
Relative sensitivity of colonoscopy and barium enema for detection of colorectal cancer
in clinical practice.
Gastroenterology.
1997;
112
17-23
16
Pickhardt P J, Choi J R, Hwang I. et al .
Computed tomographic virtual colonoscopy to screen for colorectal neoplasia in asymptomatic
adults.
N Engl J Med.
2003;
349
2191-2200
17
Pineau B C, Paskett E D, Chen G J. et al .
Virtual colonoscopy using oral contrast compared with colonoscopy for the detection
of patients with colorectal polyps.
Gastroenterology.
2003;
125
304-310
R. Eliakim, M. D.
Department of Gastroenterology · Rambam Medical Center · Haifa 31 096 · Israel ·
Fax: +972-4-854-3058
Email: r_eliakim@rambam.health.gov.il