Use of Expanders for Protection of Viscera During Irradiation of Pelvic Tumors in Children

P. -G. Helardot1 , A.  Wakim1 , S.  Benammar1 , J. L. Habrand2
  • 1Service de Chirurgie Pédiatrique, Hôpital Saint Vincent de Paul, 82 Avenue Denfert-Rochereau, Paris, France
  • 2Service de Radiothérapie, Institut Gustave Roussy, Rue Camille Desmoulins, Villejuif Cédex, France
Further Information

Publication History

Publication Date:
25 March 2008 (online)

Abstract

The authors describe a new technique for radioprotection of pelvic viscera by placement of expanders in the subperitoneal area before irradiation of pelvic tumors. They use round shape sub-cutaneous expanders, the volume corresponding to children's weight.

Seven patients were treated with excellent results, and minor complications: 2 rectitis due to unsatisfactory displacement of rectum by the balloon. There were no complications related to the device itself. The prosthesis was easy to withdraw. This method seems a safe and effective technique in protecting viscera.

Zusammenfassung

Die Autoren beschreiben eine Strahlenschutztechnik der Unterleibsorgane durch das Einsetzen einer Expansionsprothese in die Bauchfellhöhle während der Bestrahlung des Tumors im Beckenbereich. Sie benutzen runde Expansionsprothesen, die der Größe des Kindes entsprechen.

Sieben Patienten wurden auf diese Weise mit hervorragenden Ergebnissen behandelt, wobei nur wenige und relativ belanglose Komplikationen auftraten: 2 kleine Mastdarmentzündungen traten auf, bedingt durch ungenügenden Schutz des Mastdarms, der nicht weit genug durch die Prothese aus dem Strahlenbereich verdrängt wurde.

Es sind keinerlei Komplikationen der Methode selbst bekannt. Die Ablation der Prothese ist einfach.

Das Verfahren bei diesen 7 Patienten scheint sicher und wirksam.

    >