Endoscopy 2008; 40: E215-E216
DOI: 10.1055/s-2008-1077407
Unusual cases and technical notes

© Georg Thieme Verlag Stuttgart · New York

Removal of a doubly impacted plastic stent: a new technique

M.  Mutignani1 , R.  Salerno2 , V.  Perri1 , A.  Tringali1 , G.  Costamagna1
  • 1Digestive Endoscopy Unit, University Hospital A. Gemelli, Catholic University, Rome, Italy
  • 2Department of Medicine – Gastroenterology, Second University of Naples, Naples, Italy
Further Information

Publication History

Publication Date:
25 September 2008 (online)

Plastic stents are commonly used for various indications including drainage, stricture dilatation, and leakage. A complication is migration. The “Amsterdam” type stents have a slightly curved shaft and flaps near each end to prevent proximal or distal migration [1]. Despite the presence of flaps, proximal migration into the bile ducts or distal migration into the duodenum with subsequent passage per rectum are relatively frequent, but impaction and perforation of the bowel are rare [2].

In our department, we observed a 75-year-old Caucasian male with severe comorbidity admitted for obstructive jaundice and cholangitis secondary to multiple large common bile duct stones. Previous treatment was placement of a 12 cm 10 Fr plastic biliary stent for incomplete stone extraction. At endoscopic retrograde cholangiopancreatography, the distal end of the stent was found to have penetrated into the duodenal wall ([Fig. 1,] [2]). The patient had no symptoms of perforation and no retroperitoneal air was observed at fluoroscopy. The retrieval maneuver was difficult because the proximal end of the stent was impacted into the common bile duct and the distal flap of the stent was impacted at the external surface of the duodenal wall. We introduced a 0.018-inch nitinol guide wire (Roadrunner®, Cook Medical Inc., Bloomington, Indiana, USA) into the lumen of the duodenum. The distal end of the guide wire was grasped using a foreign body forceps and looped around the plastic stent before being retrieved outside the scope ([Fig. 3]). Both ends of the guide wire were locked into a mechanical lithotripsy device and spun until the stent was cut through [3] ([Fig. 4]). The distal part of the stent, which had impacted into the duodenal wall, was retrieved using forceps after positioning the scope in front of the perforation ([Fig. 5]). To prevent the stretching of the duodenal wall, it was maintained fixed against the scope while the stent segment was retrieved into the operative channel. No peri- or postprocedural complications occurred ([Fig. 6]).

Fig. 1 The forceps marks out the extraluminal part of the stent.

Fig. 2  “Road Runner” guide wire looping the stent.

Fig. 3 Radiography shows the stent being grasped using the guide wire and metal cable.

Fig. 4 End result after trimming the stent.

Fig. 5 The distal part of the stent, which had impacted into the duodenal wall, was retrieved using forceps after positioning the scope in front of the perforation.

Fig. 6 Radiograph following the procedure: there is no evidence of leakage.

Endoscopy_UCTN_Code_TTT_1AR_2AZ

References

  • 1 Chaurasia O, Rauws E, Fockens P. et al . Endoscopic Techniques For Retrieval Of Proximally Migrated Biliary Stents.  Gastrointest Endosc. 1999;  50 780-785
  • 2 Esterl Jr R M, St Laurent M, Bay M K. et al . Endoscopic biliary stent migration with small bowel perforation in a liver transplant recipient.  J Clin Gastroenterol.. 1997;  24 106-110
  • 3 Mutignani M, Dokas S, Perri V. et al . Post-insertion tailoring of plastic biliary stents.  Endoscopy. 2006;  38 856

M. Mutignani, MD 

Digestive Endoscopy Unit
University Hospital A. Gemelli

Largo A. Gemelli 8
00168 Rome
Italy

Fax: +39-06-30156581

Email: massimiliano.mutignani@rm.unicatt.it

    >