A hematoma caused by an excessively superficial injection: go under the red bleb!

Jérémie Albouys
1   Gastroentérologie et endoscopie digestive, CHU Dupuytren, Limoges, France
,
Sophie Geyl
1   Gastroentérologie et endoscopie digestive, CHU Dupuytren, Limoges, France
,
Aurélie Charissoux
2   Anatomopathologie, CHU Dupuytren, Limoges, France
,
Véronique Loustaud-Ratti
2   Anatomopathologie, CHU Dupuytren, Limoges, France
,
Romain Legros
1   Gastroentérologie et endoscopie digestive, CHU Dupuytren, Limoges, France
,
Mathieu Pioche
3   Unité d’endoscopie digestive, service de Gastroentérologie – pavillon H, Hôpital Edouard Herriot, Hospices Civils de Lyon, Lyon, France
,
Jérémie Jacques
1   Gastroentérologie et endoscopie digestive, CHU Dupuytren, Limoges, France
› Institutsangaben
 

Effective submucosal injection is key for efficient and safe endoscopic resection, such as endoscopic mucosal resection (EMR) or endoscopic submucosal dissection (ESD). Deep injection into the muscularis propria is dangerous and may result in a false non-lifting sign. A too superficial injection in the muscularis mucosae is a classic issue, associated with rapid poor lifting and a hematoma of the muscularis mucosa caused by injury to the extensive vascularization. Such a situation complicates many endoscopic resections [1]. During EMR, the scenario may compromise technical success because the lesion is not lifted. During ESD, the difficulty increases because of major bleeding and loss of the dissection plan.

We report a simple trick that greatly assists such a situation. A 2-cm-diameter, granular, laterally spreading tumor of the right colon ([Fig. 1]) was scheduled for standard EMR. The first injection was too superficial and triggered a major hematoma of the muscularis mucosae that complicated safe and efficient EMR ([Fig. 2]). We switched to ESD with traction of the dissection plane under the hematoma. We performed a second injection 1 cm distant from the hematoma. We then created a mucosal incision no closer than 1 cm from the hematoma. After dissection of the first submucosal fibers, we installed our previously reported double-clip traction device using two clips and a rubber band [2] [3]. The resultant good positioning of the submucosal plane allowed access to the deep submucosal plane under the red bleb caused by the first excessively superficial injection ([Fig. 3]). Extension of the margin and a descent under the red bleb allowed us to avoid major bleeding and perform rapid successful ESD of a 2-cm-diameter adenoma exhibiting low-grade dysplasia ([Video 1]).

Zoom Image
Fig. 1 Granular-type laterally spreading tumor in the right colon.
Zoom Image
Fig. 2 Hematoma resulting from an excessively superficial injection.
Zoom Image
Fig. 3 Endoscopic submucosal dissection under the hematoma.

Video 1 A hematoma caused by an excessively superficial injection: go under the red bleb!


Qualität:

In conclusion, if a submucosal hematoma develops because an injection is too superficial, performing deep ESD under traction after extending the margin under the red bleb facilitates endoscopic resection in this well-known, challenging situation.

Endoscopy_UCTN_Code_CPL_1AH_2AZ

Endoscopy E-Videos
https://eref.thieme.de/e-videos

Endoscopy E-Videos is a free access online section, reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high
quality video and all contributions are
freely accessible online.

This section has its own submission
website at
https://mc.manuscriptcentral.com/e-videos


#

Competing interests

Mathieu Pioche: scientific consultant for Olympus, Boston and 3D matrix, ESD training with Cook and Olympus. Véronique Loustaud-Ratti: advisory board and speaking for Gilead and Abbvie. Sophie Geyl: speaking for Abbvie and Ipsen, invitation (conference) for Amgen. Jérémie Jacques and Romain Legros: scientific consultant for Boston and Olympus, ESD training for ERBE.

  • References

  • 1 Nanda KS, Sonson RJ, Bourke MJ. Intramucosal injection: part of the spectrum of outcomes from submucosal injection during endoscopic resection. Gastrointest Endosc 2014; 80: 733-735
  • 2 Jacques J, Charissoux A, Legros R. et al. Double-clip counter-traction using a rubber band is a useful and adaptive tool for colonic endoscopic submucosal dissection. Endoscopy 2018; 50: 179-181
  • 3 Jacques J, Charissoux A, Bordillon P. et al. High proficiency of colonic endoscopic submucosal dissection in Europe thanks to countertraction strategy using a double clip and rubber band. Endosc Int Open 2019; 7: E1166-E1174

Corresponding author

Jérémie Albouys, MD
Service d’Hépato-gastroentérologie
CHU Dupuytren 87042
Limoges
France   
Fax: +33-5-55058733

Publikationsverlauf

Artikel online veröffentlicht:
19. Mai 2020

© 2020. Thieme. All rights reserved.

Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany

  • References

  • 1 Nanda KS, Sonson RJ, Bourke MJ. Intramucosal injection: part of the spectrum of outcomes from submucosal injection during endoscopic resection. Gastrointest Endosc 2014; 80: 733-735
  • 2 Jacques J, Charissoux A, Legros R. et al. Double-clip counter-traction using a rubber band is a useful and adaptive tool for colonic endoscopic submucosal dissection. Endoscopy 2018; 50: 179-181
  • 3 Jacques J, Charissoux A, Bordillon P. et al. High proficiency of colonic endoscopic submucosal dissection in Europe thanks to countertraction strategy using a double clip and rubber band. Endosc Int Open 2019; 7: E1166-E1174

Zoom Image
Fig. 1 Granular-type laterally spreading tumor in the right colon.
Zoom Image
Fig. 2 Hematoma resulting from an excessively superficial injection.
Zoom Image
Fig. 3 Endoscopic submucosal dissection under the hematoma.