Endoscopy 2021; 53(04): E132-E133
DOI: 10.1055/a-1216-0271
E-Videos

Closure of residual fistula after esophageal atresia repair in a 5-year-old using endoscopic submucosal dissection of surrounding mucosa

Grégoire Lavaud
1   Department of Pediatric Endoscopy and Gastroenterology, Hôpital Femme Mère Enfant, Lyon, France
2   Department of Endoscopy and Gastroenterology, Pavillon L, Edouard Herriot Hospital, Lyon, France
,
Sophie Heissat
1   Department of Pediatric Endoscopy and Gastroenterology, Hôpital Femme Mère Enfant, Lyon, France
,
Auxane Chauveau
2   Department of Endoscopy and Gastroenterology, Pavillon L, Edouard Herriot Hospital, Lyon, France
,
Noël Peretti
1   Department of Pediatric Endoscopy and Gastroenterology, Hôpital Femme Mère Enfant, Lyon, France
,
Alain Lachaux
1   Department of Pediatric Endoscopy and Gastroenterology, Hôpital Femme Mère Enfant, Lyon, France
,
Borathchakra Oung
2   Department of Endoscopy and Gastroenterology, Pavillon L, Edouard Herriot Hospital, Lyon, France
,
Mathieu Pioche
2   Department of Endoscopy and Gastroenterology, Pavillon L, Edouard Herriot Hospital, Lyon, France
3   INSERM U1032, LabTau, Lyon, France
› Institutsangaben
 

Esotracheal fistulas after esophageal atresia repair recur in 5 to 10 % of cases [1] [2] and lead to recurrent pneumonia or mediastinitis. Several surgical techniques are effective in closing an esotracheal fistula by thoracotomy or cervicotomy [3], but endoscopic success has never been published for this indication.

We present the case of a 5-year-old patient with a previous history of type III esophageal atresia neonatal surgery, chronic respiratory congestion, and poor weight gain. She experienced a fistula recurrence with a large tracheoesophageal defect ([Fig. 1]).

Zoom Image
Fig. 1 First endoscopic submucosal dissection to remove mucosa surrounding the fistula. a Appearance of the residual tracheoesophageal fistula (red arrow showing the fistula). b, c Deep dissection of the entire fistulous tract using a clip-and-line system. d Clips placed in the submucosa to close the orifice.

We performed an endoscopic fistula closure after prior endoscopic submucosal dissection (ESD) of the surrounding mucosa as previously reported for a button battery-induced esotracheal fistula [4] or idiopathic chronic fistula [5]. The patient underwent tracheal intubation with balloon placement just under the fistula. ESD was assisted by clip-and-line traction to dissect deeper into the fistula tract ([Video 1]). Once the mucosa was resected, we closed the area using four clips anchored in the submucosa. A radiological check objectified the tightness of the closure.

Video 1 Successful endoscopic closure of a residual fistula after esophageal atresia repair in a 5-year-old using endoscopic submucosal dissection of the surrounding mucosa.


Qualität:

The postoperative consequences were favorable, marked by a disappearance of the patient's respiratory symptoms during the following 3 months. A radiological check with opacification carried out 3 months before the gesture shows a tiny residual fistula and pseudo-diverticular scarring ([Fig. 2]). The patient underwent a second procedure, during which ESD of the surrounding mucosa was done with deep cutting of the diverticular wall. Then, a new closure of the resected area was done. The closure of the residual fistula was confirmed by radiological control after 1 month.

Zoom Image
Fig. 2 Aspect of esophageal transit before and after the second procedure. a Radiological opacification after first endoscopic closure: small residual fistula and pseudo-diverticular scarring (red arrow showing the fistula). b Radiological opacification after second endoscopic gesture: no residual fistula.

Currently, the management of recurrent esotracheal fistulas after atresia surgery is not well defined. Endoscopic closure after ESD of the surrounding mucosa could allow a definitive resolution of the esotracheal fistulas and avoid a second risky surgery.

Endoscopy_UCTN_Code_TTT_1AO_2AI

Endoscopy E-Videos
https://eref.thieme.de/e-videos

Endoscopy E-Videos is a free access online section, reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high
quality video and all contributions are
freely accessible online.

This section has its own submission
website at
https://mc.manuscriptcentral.com/e-videos


#

Competing interests

The authors declare that they have no conflict of interest.

  • References

  • 1 Kovesi T, Rubin S. Long-term complications of congenital esophageal atresia and/or tracheoesophageal fistula. Chest 2004; 126: 915-925
  • 2 Bruch SW, Hirschl RB, Coran AG. The diagnosis and management of recurrent tracheoesophageal fistulas. J Pediatr Surg 2010; 45: 337-340
  • 3 Daniel SJ, Smith MM. Tracheoesophageal fistula: open versus endoscopic repair. Curr Opin Otolaryngol Head Neck Surg 2016; 24: 510-515
  • 4 Gruner M, Heissat S, Pitiot V. et al. Successful endoscopic closure of a refractory button-battery tracheoesophageal fistula in a 3-year child using endoscopic submucosal dissection of the surrounding mucosa. Endoscopy 2017; 49: E212-E214
  • 5 Bertrand G, Jacques J, Rivory J. et al. Deep endoscopic submucosal dissection of a refractory tracheoesophageal fistula using clip-and-line traction: a successful closure. Endoscopy 2017; 49: 1278-1280

Corresponding author

Dr. Mathieu Pioche
Endoscopy Unit – Digestive Disease Department
Pavillon L – Edouard Herriot Hospital
69437 Lyon Cedex
France   
Fax: +33-472-110-147   

Publikationsverlauf

Artikel online veröffentlicht:
05. August 2020

© 2020. Thieme. All rights reserved.

Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany

  • References

  • 1 Kovesi T, Rubin S. Long-term complications of congenital esophageal atresia and/or tracheoesophageal fistula. Chest 2004; 126: 915-925
  • 2 Bruch SW, Hirschl RB, Coran AG. The diagnosis and management of recurrent tracheoesophageal fistulas. J Pediatr Surg 2010; 45: 337-340
  • 3 Daniel SJ, Smith MM. Tracheoesophageal fistula: open versus endoscopic repair. Curr Opin Otolaryngol Head Neck Surg 2016; 24: 510-515
  • 4 Gruner M, Heissat S, Pitiot V. et al. Successful endoscopic closure of a refractory button-battery tracheoesophageal fistula in a 3-year child using endoscopic submucosal dissection of the surrounding mucosa. Endoscopy 2017; 49: E212-E214
  • 5 Bertrand G, Jacques J, Rivory J. et al. Deep endoscopic submucosal dissection of a refractory tracheoesophageal fistula using clip-and-line traction: a successful closure. Endoscopy 2017; 49: 1278-1280

Zoom Image
Fig. 1 First endoscopic submucosal dissection to remove mucosa surrounding the fistula. a Appearance of the residual tracheoesophageal fistula (red arrow showing the fistula). b, c Deep dissection of the entire fistulous tract using a clip-and-line system. d Clips placed in the submucosa to close the orifice.
Zoom Image
Fig. 2 Aspect of esophageal transit before and after the second procedure. a Radiological opacification after first endoscopic closure: small residual fistula and pseudo-diverticular scarring (red arrow showing the fistula). b Radiological opacification after second endoscopic gesture: no residual fistula.