Background
The corpus callosum is the largest telencephalic commissure which enables the communication
between the left and right hemisphere of the brain [1]. It is therefore an important anatomical landmark for the evaluation of normal fetal
brain development [2]
[3]
[4].
In prenatal diagnosis the occurrence of corpus callosum pathologies is significantly
underestimated. While a large number of studies on fetal agenesis of the corpus callosum
[5]
[6]
[7]
[8]
[9]
[10] has been published, reports on the diagnosis of partial agenesis, hypoplasia, and
hyperplasia of the corpus callosum are scarce [11]
[12]. The described malformations require not only a precise demonstration of the corpus
callosum in the median plane of the fetal brain but also exact knowledge of the normal
reference ranges of the prenatal corpus callosum lengths and heights of the different
anatomical parts [11].
In comparison to 2D ultrasound, 3D sonography allows a more precise demonstration
of the corpus callosum due to the fact that the median plane can be controlled by
the two perpendicular planes and corrected with the rotation controls.
However, there are conflicting data in the literature regarding the ultrasound appearance
of the corpus callosum by means of 2D and 3D ultrasound. 2D studies have described
the corpus callosum as a hypoechoic structure [2]
[13], while in the 3D mid-sagittal plane reconstructed from volumes acquired in axial
planes, the corpus callosum has been defined as a hyperechoic structure [14]
[15]
[16]
[17].
The aim of the present article is to outline the correct approach to volume acquisition
of the fetal brain that allows an accurate demonstration and evaluation of the corpus
callosum.
Practical points
2D and 3D ultrasound appearance of the corpus callosum
Using either 2D or 3D ultrasound, the corpus callosum is correctly displayed as an
anechoic to hypoechoic curved band between the gyrus cinguli superiorly and the cavum
septi pellucidi and the cavum vergae inferiorly and is demarcated by two echogenic
lines [12] ([Fig. 1a, b]). Normal development of the corpus callosum confirmed by ultrasound requires measurement
of the corpus callosum length (outer-outer, inner-inner, or curved length) as well
as of the height of each of the four anatomical parts (rostrum, genu, body, and splenium)
[12].
Fig. 1 a Transvaginally acquired 2D image of a fetal brain at 20 weeks of gestation. The corpus
callosum is demonstrated as a hypoechoic structure. However, the irregular appearance
of the brain surface (arrows) indicates that the 2D image does not show a correct
median plane. b Transvaginally acquired 3D ultrasound volume of the fetal brain at 20 gestational
weeks, demonstrating the surface rendered image of an exact midsagittal plane with
regular appearance of the brain surface (arrows). As in 2D ultrasound the corpus callosum
is shown as a hypoechoic structure. ant. = anterior, post. = posterior.
Why is 3D sonography superior to 2D ultrasound in the demonstration of the corpus
callosum?
Both 2D and 3D ultrasound use the same acoustic windows for the demonstration of the
brain anatomy and all scanning planes emerge from a single point in the acoustic window.
In 2D ultrasound the probe must be moved manually to visualize different planes, while
in 3D probes the scanning plane is moved automatically in a fan-like fashion enabling
the acquisition of a volume in the shape of a truncated pyramid [3]. From this volume all planes, oblique and parallel ones, can be reconstructed by
volume manipulation.
In most fetuses in breech position and transverse lie, the exact midsagittal plane
of the fetal head is technically difficult to obtain with standard 2D transabdominal
ultrasound [18]. In fetuses with vertex presentation, transvaginal sonography is the technique of choice
for fetal neurosonography [10]
[12]. However, using 2D ultrasound, there is no control regarding the exact median plane.
There are several advantages of three-dimensional ultrasound over two-dimensional
imaging for the visualization of the corpus callosum:
1. 3D ultrasound enables volume acquisition of the brain also in difficult positions
of the fetal head. The corpus callosum can be shown in an exact midsagittal plane
([Fig. 2]) by manipulating the stored volume using the rotation controls. The two perpendicular
planes allow exact control of the median plane. Such control is not available with
2D ultrasound.
Fig. 2 Multiplanar and surface rendered demonstration of the fetal brain (21 weeks of gestation).
a Median plane, showing the hypoechoic corpus callosum, b coronal plane, and c axial plane. d Surface rendered image of the median plane with the corpus callosum.
2. 3D ultrasound facilitates the correct anatomical orientation in the fetal brain
and the demonstration of the entire corpus callosum. As a three-dimensional curved
structure, the corpus callosum should be assessed in all three orthogonal planes:
the sagittal, the axial, and the coronal. The multiplanar mode enables correct anatomical
orientation within the volume by using the midline structures of the fetal brain such
as the interhemispheric fissure, the cavum septi pellucidi, the cavum vergae, and
vermis cerebelli in all three planes ([Fig. 2]).
3. The 3D ultrasound surface mode and the VCI mode enhance the brain structures and
thus the image quality.
4. 3D ultrasound reduces the examination time.
5. 3D ultrasound facilitates the demonstration of the corpus callosum by less experienced
operators.
6. The possibility to store volumes digitally without any quality loss, allows reloading
and manipulation of each volume by different experts in different display modes.
Position of the fetus and the mother
In fetuses with vertex presentation, transvaginal sonography is recommended for the
demonstration of the corpus callosum. The maternal bladder should be empty to reduce
the distance between the probe and the corpus callosum. In fetuses with breech presentation
or transverse lie, an abdominal 3D probe is used. In vertex presentation the demonstration
of the corpus callosum is also feasible with the transabdominal probe, however only
if the fetal head is not deeply engaged in the pelvis. In cases of asynclitism of
the fetal head, manipulation from the abdominal site with the free hand of the operator
is recommended to bring the head into a more favorable position. If the fetus is in
breech or transverse presentation, rotation of the mother to her right or left side
may permit an optimal position of the anterior fontanelle to be used as an acoustic
window. In breech presentation a sitting position of the mother ([Fig. 3]) may be helpful to demonstrate the corpus callosum exactly.
Fig. 3 Demonstration of the volume acquisition of the fetal brain with the mother in a sitting
position when the fetus is in a difficult breech presentation.
Volume acquisition of the corpus callosum is performed in the absence of fetal movements
or maternal breathing.
What are the best acoustic windows for the demonstration of the corpus callosum?
In the second trimester, depending on the fetal position, the volume of the corpus
callosum can be acquired with the abdominal or transvaginal 3D transducer, using either
the anterior fontanelle or the sagittal suture as an acoustic window like in 2D ultrasound
([Fig. 4a]). This enables the reconstruction of sagittal, parasagittal, coronal, and oblique
planes of the fetal brain [4]
[19] ([Fig. 4b]). In the third trimester the corpus callosum is better visualized from the anterior
fontanelle in the sagittal plane due to the reduction of suture width. The lambdoid
suture and posterior fontanelle do not allow clear visualization of the rostrum and
genu, whereas the metopic suture does not provide information on the posterior part
of the body and the splenium. The sphenoid and mastoid fontanelle or the coronal and
lambdoid suture are not recommended for volume acquisition to demonstrate the corpus
callosum.
Fig. 4 a Volume acquisition of the fetal brain: the sagittal suture is used as an acoustic
window (red line). b 3D volume of the fetal brain acquired from the sagittal suture which allows correct
demonstration of the corpus callosum.
Is it important to visualize the entire corpus callosum before volume acquisition?
2D visualization of the entire corpus callosum is not mandatory prior to volume acquisition.
It is of greater importance to ascertain that all parts of the corpus callosum are
visualized during the process of volume acquisition. To include most of the brain
in the volume, the sweep angle for the volume acquisition must be set at least between
45° and 80° depending on the gestational age. However, this is difficult to achieve
in the late third trimester.
Once the brain volume containing the corpus callosum is acquired, the three perpendicular
planes can be corrected with the use of the rotation controls, until the corpus callosum
is seen in the correct median plane.
Which are the most suitable scanning planes to acquire the volume?
The best demonstration of the corpus callosum is possible when the brain volume is
acquired from a sagittal or parasagittal plane or from the three-horn view ([Fig. 1], [2]). This requires only a small volume angle with a low risk of motion artifacts and
enables the highest image quality. Acquisition from a coronal plane may be possible
in a limited number of cases in the second trimester ([Fig. 5]). However, a high-volume angle is necessary to include the entire corpus callosum.
This increases the risk of motion artifacts during volume acquisition. Furthermore,
acquisition from a coronal plane is not achievable in the third trimester due to the
narrowing of the sutures and anterior fontanelle and the increased length of the corpus
callosum. Therefore, acquisition from a coronal plane is not recommended for daily
routine applications.
Fig. 5 Transvaginal 3D ultrasound volume of the fetal brain at 26 gestational weeks, acquired
from the coronal plane using a sweep angle of 120° that includes the entire brain
for visualization of the whole corpus callosum. a coronal plane, b sagittal plane, c axial plane.
Which planes are NOT recommended to use for the acquisition of a volume to demonstrate
the corpus callosum?
Volume acquisition of the corpus callosum from an axial plane of the fetal head is
not recommended because the median plane always remains a reconstructed plane with
low image quality and shows the corpus callosum incorrectly as a hyperechoic structure
([Fig. 6]). Even if the volume acquired from the axial plane of the fetal head is examined
with different 3D display modes such as VCI, tomographic display ([Fig. 7]), OmniView-VCI ([Fig. 8].), or the surface mode, the C-plane always remains a reconstructed one which does
not allow an exact diagnostic evaluation of the normal and abnormal corpus callosum
([Fig. 9]). The appearance of corpus callosum as a hyperechoic structure may be due to the
simultaneous use of 3D voxel reconstruction in conjunction with speckle reduction
imaging (SRI) and represents the interface between the cingulated gyrus, the cingulated
sulcus, cerebrospinal fluid, and the blood flow in the callosal arteries [20].
Fig. 6 3D acquisition of the fetal brain from an axial plane. The reconstructed mid-sagittal
plane does not allow a clear evaluation of the corpus callosum that is erroneously
depicted as a hyperechoic structure. a axial plane, b coronal plane, c sagittal plane.
Fig. 7 Tomographic demonstration of the same volume as in [Fig. 6]. Also, in this mode the corpus callosum has a hyperechoic appearance and does not
show all its anatomical parts.
Fig. 8 The same volume of the fetal brain as in [Fig. 6], [7] displayed with OmniView mode showing the corpus callosum as a hyperechoic structure.
Fig. 9 The same case as in [Fig. 6], [7], [8]. The volume is acquired from a parasagittal plane. After rotating the volume with
the rotation controls, the exact median plane can be displayed, showing the corpus
callosum with its four anatomical parts as a hypoechoic structure in the surface rendered
image.
A true hyperechoic corpus callosum is only seen in cases of corpus callosum lipoma.
How to manipulate the volume for the demonstration of the corpus callosum
Once the volume containing the corpus callosum is acquired from a sagittal or parasagittal
plane and stored in the memory of the ultrasound device, the three orthogonal planes
can be manipulated by rotation and/or translation maneuvers in the multiplanar display
mode to achieve the standard orientation ([Fig. 10a]) of the corpus callosum. The sagittal plane is displayed in plane A, the coronal
plane is depicted in plane B, and the axial plane in plane C.
Fig. 10 a Volume of the fetal brain acquired transvaginally from the three-horn view, demonstrating
the three orthogonal planes. 31 weeks of gestation. b Plane A displays the parasagittal plane of the brain, plane B demonstrates the coronal
plane and plane C displays the axial plane. The reference dot is now placed in the
interhemispheric fissure in the coronal plane. c The coronal plane is rotated about the Z axis until the interhemispheric fissure
is seen in an exact vertical orientation. d Demonstration of the rotation of the axial plane C until the interhemispheric fissure
is in an exact horizontal position. In this manner, plane A reveals the exact median
plane with the entire corpus callosum. e Surface rendered image of the median plane with the entire corpus callosum as a hypoechoic
structure.
The reference dot is placed in the interhemispheric fissure in the coronal plane ([Fig. 10b]) and the coronal plane is rotated about the Z axis until the interhemispheric fissure
is seen in an exact vertical orientation ([Fig. 10c]). Then the axial plane C has to be rotated about the reference dot until the interhemispheric
fissure is seen in an exact horizontal position ([Fig. 10d]). In this manner, plane A reveals the exact median plane with the entire corpus
callosum. This plane enables the operator also to observe other anatomical structures
such as the cavum septi pellucidi, the head of the caudate nucleus, the thalamus,
parts of the midbrain, the cerebellar vermis, cisterna magna as well as the third
and fourth ventricle ([Fig. 10d]). Once the entire corpus callosum is correctly demonstrated in the multiplanar mode,
surface reconstruction of the median plane can be performed.
Throughout the entire prenatal period, the corpus callosum is sonographically correctly
displayed as an anechoic or hypoechoic structure with clear demarcation from the cavum
septi pellucidi and cavum vergae [12]. The four different structural parts of the corpus callosum, i. e., the rostrum,
the genu, the body, and the splenium ([Fig. 10e]) [12] can be assessed in the median plane. The rostrum has been defined as a beak-shaped
segment curving posteriorly or posteroinferiorly from the genu. The genu has been
described as the curved anterior portion of the corpus callosum [12]. The body has been defined as the hypoechoic linear horizontal structure of the
corpus callosum, while the splenium represents the caudally oriented posterior portion.
Conclusion
3D ultrasound is an excellent clinical tool to demonstrate the fetal corpus callosum
precisely. The anterior fontanelle serves as the best acoustic window for the demonstration
of the corpus callosum. The volume with the corpus callosum should be acquired from
a sagittal or parasagittal sectional plane of the brain. Once the volume has been
stored in the memory of the ultrasound machine, the multiplanar mode enables the operator
to correct planes in all three dimensions. After the exact demonstration of the median
plane, the corpus callosum is seen as a hypo- or anechoic structure. The reconstructed
midsagittal plane derived from the axial planes of the fetal head is not recommended
for clinical evaluation of the corpus callosum because it does not allow a clear delineation
of the corpus callosum and therefore no correct detection of corpus callosum abnormalities.