Endoscopy 2010; 42: E89-E90
DOI: 10.1055/s-0029-1243880
Unusual cases and technical notes

© Georg Thieme Verlag KG Stuttgart · New York

Management of benign intrahepatic bile duct strictures: initial experience with polydioxanone biodegradable stents

J.  Petrtýl1 , R.  Brůha1 , L.  Horák2 , Z.  Zádorová3 , J.  Doseděl4 , H.-U.  Laasch5
  • 11st Faculty of Medicine, Charles University, Prague, 4th Department of Internal Medicine, General Teaching Hospital, Prague, Czech Republic
  • 23rd Faculty of Medicine, Charles University, Prague, Department of General Surgery, Faculty Hospital Kralovske Vinohrady, Prague, Czech Republic
  • 33rd Faculty of Medicine, Charles University, Prague, 2nd Department of Internal Medicine, Faculty Hospital Kralovske Vinohrady, Prague, Czech Republic
  • 4Department of Internal Medicine, Hospital of Saint Charles of Boromej, Prague, Czech Republic
  • 5Department of Radiology, The Christie NHS Foundation Trust, Manchester, UK
Further Information

Dr. H.-U. LaaschMRCP, FRCR 

Consultant Radiologist
The Christie NHS Foundation Trust

Wilmslow Road
Manchester M20 4BX
UK

Fax: +44 161 4468505

Email: HUL@christie.nhs.uk

Publication History

Publication Date:
01 March 2010 (online)

Table of Contents

Benign biliary strictures are challenging to manage. They often affect young patients, and although they have a good long-term prognosis, they frequently recur and patients remain at risk of life-threatening cholangitis and liver cirrhosis. Older patients may not be fit for surgery or multiple procedures, but permanent stent insertion has a poor outcome.

Balloon dilation often only results in short-term improvement. Long-term patency can be improved by “splinting” the stricture endoscopically with multiple plastic stents [1], but biliary dilation is extremely painful and repeated endoscopic retrograde cholangiopancreatography (ERCP) is expensive and associated with significant morbidity. Temporary stenting with removable metal stents is a promising new strategy [2], however, these require removal.

A new biodegradable stent theoretically allows long-term dilatation without the need for removal. It is woven from a monofilament of specially treated polydioxanone ([Fig. 1]), a resorbable suture and implant material that has been in use for over 20 years [3].

Zoom Image

Fig. 1 A 10-mm diameter Ella-DV stent.

Degradation occurs by hydrolysis [4]. The monofilament loses 50 % of its breaking strength after 3 weeks and is absorbed within 6 months [5]; a reduced pH hastens hydrolysis. Larger stent versions are already available for benign esophageal strictures. We describe the first use of 10-mm stents in the biliary tree.

Two patients (74 and 70 years) who had undergone bilioenteric anastomosis for stone disease presented 2 years after surgery with intrahepatic biliary strictures causing new stone formation and chronic cholangitis. Percutaneous balloon dilation, cholangioscopy, and lithotripsy were carried out and biodegradable Ella-DV biliary stents (ELLA-CS, Hradec Kralove, Czech Republic) inserted to prevent stricture recurrence ([Figs. 2 6]).

Zoom Image

Fig. 2 Percutaneous transhepatic cholangiogram: injection through a right-sided biliary catheter (white arrow) shows a short stricture in the left hepatic duct above the bifurcation (arrow) with filling defects caused by stones above it (arrowheads).

Zoom Image

Fig. 3 Balloon dilation of the stricture. Note the shouldering of the balloon where it exits from the percutaneous sheath (arrow).

Zoom Image

Fig. 4 Cholangioscopy before and after lithotripsy.

Zoom Image

Fig. 5 Introduction of the stent delivery system. The stent is radiolucent, but identified by the radiopaque markers (arrows).

Zoom Image

Fig. 6 Deployed stent. The site of the stricture is fully dilated (arrow) and there is free drainage of the contrast through the mesh of the stent into the common bile duct and duodenum.

The patients developed transient cholangitis as stent fragments were passed three months later. However, no further intervention was required, and 2 years after implantation the patients remain asymptomatic with normal liver function.

The optimal aftercare to prevent cholangitis at stent disintegration needs further investigation, but initial results regarding stent insertion and stricture patency are encouraging.

#

Acknowledgment

The treatment was supported by a state grant from the Ministry of Industry and Trade of the Czech Republic (Project IMPULS, project no.: FI-IM2/108).

Endoscopy_UCTN_Code_TTT_1AR_2AZ

#

References

  • 1 Costamagna G, Shah S K, Tringali A. Current management of postoperative complications and benign biliary strictures.  Gastrointest Endosc Clin N Am. 2003;  13 635-648
  • 2 Gwon D I, Shim H J, Kwak B K. Retrievable biliary stent-graft in the treatment of benign biliary strictures.  J Vasc Interv Radiol. 2008;  19 1328-1335
  • 3 Ray J A, Doddi N, Regula D. et al . Polydioxanone (PDS), a novel monofilament synthetic absorbable suture.  Surg Gynecol Obstet. 1981;  153 497-507
  • 4 Sabino A M, Gonzales S, Marquez L, Feijoo J L. Study of the hydrolytic degradation of polydioxanone PPDX.  Polym Degrad Stab. 2000;  69 209-216
  • 5 Middleton J C, Tipton A J. Synthetic biodegradable polymers as medical devices.  Medical Plastics and Biomaterials. 1998;  3 30-39

Dr. H.-U. LaaschMRCP, FRCR 

Consultant Radiologist
The Christie NHS Foundation Trust

Wilmslow Road
Manchester M20 4BX
UK

Fax: +44 161 4468505

Email: HUL@christie.nhs.uk

#

References

  • 1 Costamagna G, Shah S K, Tringali A. Current management of postoperative complications and benign biliary strictures.  Gastrointest Endosc Clin N Am. 2003;  13 635-648
  • 2 Gwon D I, Shim H J, Kwak B K. Retrievable biliary stent-graft in the treatment of benign biliary strictures.  J Vasc Interv Radiol. 2008;  19 1328-1335
  • 3 Ray J A, Doddi N, Regula D. et al . Polydioxanone (PDS), a novel monofilament synthetic absorbable suture.  Surg Gynecol Obstet. 1981;  153 497-507
  • 4 Sabino A M, Gonzales S, Marquez L, Feijoo J L. Study of the hydrolytic degradation of polydioxanone PPDX.  Polym Degrad Stab. 2000;  69 209-216
  • 5 Middleton J C, Tipton A J. Synthetic biodegradable polymers as medical devices.  Medical Plastics and Biomaterials. 1998;  3 30-39

Dr. H.-U. LaaschMRCP, FRCR 

Consultant Radiologist
The Christie NHS Foundation Trust

Wilmslow Road
Manchester M20 4BX
UK

Fax: +44 161 4468505

Email: HUL@christie.nhs.uk

Zoom Image

Fig. 1 A 10-mm diameter Ella-DV stent.

Zoom Image

Fig. 2 Percutaneous transhepatic cholangiogram: injection through a right-sided biliary catheter (white arrow) shows a short stricture in the left hepatic duct above the bifurcation (arrow) with filling defects caused by stones above it (arrowheads).

Zoom Image

Fig. 3 Balloon dilation of the stricture. Note the shouldering of the balloon where it exits from the percutaneous sheath (arrow).

Zoom Image

Fig. 4 Cholangioscopy before and after lithotripsy.

Zoom Image

Fig. 5 Introduction of the stent delivery system. The stent is radiolucent, but identified by the radiopaque markers (arrows).

Zoom Image

Fig. 6 Deployed stent. The site of the stricture is fully dilated (arrow) and there is free drainage of the contrast through the mesh of the stent into the common bile duct and duodenum.