Novel technique for placement of overlapping self-expandable metal stents to close a massive pancreatitis-induced duodenal fistula

A. S. Rao
1   Division of Gastroenterology, Mayo Clinic, Rochester, Minnesota, USA
,
A. J. LeRoy
2   Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
,
E. A. Bonin
1   Division of Gastroenterology, Mayo Clinic, Rochester, Minnesota, USA
,
S. R. Sweetser
1   Division of Gastroenterology, Mayo Clinic, Rochester, Minnesota, USA
,
T. H. Baron
1   Division of Gastroenterology, Mayo Clinic, Rochester, Minnesota, USA
› Author Affiliations
Further Information

Corresponding author

T. H. Baron, MD
200 First Street SW
Rochester
MN 55905
USA   
Fax: +1-507-266-3939   

Publication History

Publication Date:
23 May 2012 (online)

 

A 67-year-old man with infected pancreatic necrosis underwent serial endoscopic necrosectomies through a spontaneously formed massive duodenal fistula ([Fig. 1]). He also required percutaneous drainage of a communicating paracolic gutter collection.

Zoom Image
Fig. 1 Endoscopic images showing the massive fistula on the right. The arrow denotes the narrowed duodenal lumen. a The endoscope is situated just across the fistula passing into the remaining necrotic cavity with an indwelling catheter. b Endoscopic view from the duodenal bulb.

Despite resolution of necrosis, the fistula remained open with high-volume output through the percutaneous drain. The patient’s severe coronary disease precluded surgical repair. Transoral placement of a fully covered esophageal self-expandable metal stent (SEMS) was attempted but failed due to looping of the delivery system within the stomach. To overcome this obstacle, a fluoroscopically guided percutaneous gastrostomy puncture was performed by an interventional radiologist; the tract was balloon dilated to 10 mm, and a 26-Fr Amplatz Renal Introducer Sheath (Cook Urological Inc., Spencer, Indiana, USA) was inserted into the gastric lumen. Through the sheath, a guide wire was positioned into the distal duodenum, and a 12-cm long, 23-mm diameter, partially covered esophageal SEMS (Ultraflex; Boston Scientific, Natick, Massachusetts, USA) was deployed across the fistula under fluoroscopy.

Contrast injection showed continued leakage through the fistula ([Fig. 2]). Therefore, a 7-cm long, 18-mm diameter, fully covered esophageal SEMS (Alimaxx; Merit Medical Endotek, South Jordan, Utah, USA) was passed through the gastrostomy sheath and fluoroscopically deployed within the first stent in an overlapping fashion. Contrast injection confirmed luminal patency without further leakage ([Fig. 3]).

Zoom Image
Fig. 2 Radiographic image immediately after deployment of initial partially covered esophageal stent through the transgastric sheath. Contrast injection shows continued leakage through the fistula communicating with a percutaneous pigtail catheter.
Zoom Image
Fig. 3 Radiographic image immediately after deployment of second distally placed fully covered esophageal stent in overlapping fashion through the transgastric sheath. Contrast injection shows no residual extravasation through the fistulous tract.

After 2 months, an upper gastrointestinal series revealed persistent absence of contrast extravasation. Fistula closure was endoscopically confirmed, and stent removal was performed by forceps extraction. The patient remains well 2 years later.

Gastroduodenal SEMS are typically utilized for palliation of malignant obstruction, but have also been used to close fistulas after gastric surgery [1] [2] [3] [4] as well as to close iatrogenic duodenal perforations [5]. However, their use in the small intestine is limited by difficult placement due to imperfect delivery systems. Our case illustrates an innovative approach for SEMS deployment through a gastrostomy site to treat a massive pancreatitis-induced duodenal fistula.

Endoscopy_UCTN_Code_TTT_1AO_2AZ


#

Competing interests: None

  • References

  • 1 Kriwanek S, Ott N, Ali-Abdullah S et al. Treatment of gastro-jejunal leakage and fistulization after gastric bypass with coated self-expanding stents. Obes Surg 2006; 16: 1669-1674
  • 2 Salinas A, Baptista A, Santiago E et al. Self-expandable metal stents to treat gastric leaks. Surg Obes Relat Dis 2006; 2: 570-572
  • 3 Bona D, Sarli D, Saino G et al. Successful conservative management of benign gastro-bronchial fistula after intrathoracic esophagogastrostomy. Ann Thorac Surg 2007; 84: 1036-1038
  • 4 Curcio G, Mocciaro F, Tarantino I et al. Self-expandable metal stent for closure of a large leak after total gastrectomy. Case Rep Gastroenterol 2010; 4: 293-297
  • 5 Small AJ, Petersen BT, Baron TH. Closure of a duodenal stent-induced perforation by endoscopic stent removal and covered self-expandable metal stent placement (with video). Gastrointest Endosc 2007; 66: 1063-1065

Corresponding author

T. H. Baron, MD
200 First Street SW
Rochester
MN 55905
USA   
Fax: +1-507-266-3939   

  • References

  • 1 Kriwanek S, Ott N, Ali-Abdullah S et al. Treatment of gastro-jejunal leakage and fistulization after gastric bypass with coated self-expanding stents. Obes Surg 2006; 16: 1669-1674
  • 2 Salinas A, Baptista A, Santiago E et al. Self-expandable metal stents to treat gastric leaks. Surg Obes Relat Dis 2006; 2: 570-572
  • 3 Bona D, Sarli D, Saino G et al. Successful conservative management of benign gastro-bronchial fistula after intrathoracic esophagogastrostomy. Ann Thorac Surg 2007; 84: 1036-1038
  • 4 Curcio G, Mocciaro F, Tarantino I et al. Self-expandable metal stent for closure of a large leak after total gastrectomy. Case Rep Gastroenterol 2010; 4: 293-297
  • 5 Small AJ, Petersen BT, Baron TH. Closure of a duodenal stent-induced perforation by endoscopic stent removal and covered self-expandable metal stent placement (with video). Gastrointest Endosc 2007; 66: 1063-1065

Zoom Image
Fig. 1 Endoscopic images showing the massive fistula on the right. The arrow denotes the narrowed duodenal lumen. a The endoscope is situated just across the fistula passing into the remaining necrotic cavity with an indwelling catheter. b Endoscopic view from the duodenal bulb.
Zoom Image
Fig. 2 Radiographic image immediately after deployment of initial partially covered esophageal stent through the transgastric sheath. Contrast injection shows continued leakage through the fistula communicating with a percutaneous pigtail catheter.
Zoom Image
Fig. 3 Radiographic image immediately after deployment of second distally placed fully covered esophageal stent in overlapping fashion through the transgastric sheath. Contrast injection shows no residual extravasation through the fistulous tract.