Keywords
field conditions - hydrophilic - hydrophobic - retention - resin - sealant
Introduction
Dental caries is the most globally pervasive disease affecting general health along
with impairing the quality of life of billions worldwide.[1] The adequate use of fluoride and mechanical plaque control has reduced the dental
caries prevalence.[1] However, these preventive regimens are less effective on the occlusal part of the
tooth where the complex natural morphology, pits, and fissures easily accumulate food
debris and dental plaque.[2]
Sealant is typically a resin-based or glass ionomer-based material that flows into
and seals pits and fissures.[2] Placing a sealant physically blocks cariogenic substances and bacterial build-up
in these deep grooves.[2] Sealant has long been used and reduces the risk of developing new carious lesions
by 76%.[2] Placing a sealant is effective on sound tooth surface and can be used on early noncavitated
caries to inhibit its progression.[3]
The clinical retention of sealant material has been used to evaluate its efficacy.[2] This is because the barricade between the caries-related factors and the protected
surface is due to the tight sealing quality of the material. The first marketed sealants,
which are resin-based materials, have the highest retention rates among sealant types.[4] However, this material is highly technique sensitive due to its hydrophobicity.[4] Therefore, in conditions where adequate moisture control cannot be achieved, the
retention rate is reduced.[4] Partially erupted teeth with soft tissue impingement, uncooperative children, or
those with special needs, and not having the appropriate moisture-control equipment
can result in unsatisfactory sealant retention.[5]
A novel resin-based sealant was fabricated by modifying the chemical part of the monomer,
which converted the hydrophobic sealant into a moisture-friendly material.[6] This material has been commercially available but is not widely used clinically.
In vitro studies have demonstrated that the hydrophilic sealant has physical properties similar
to the hydrophobic resin-based sealant, for example, low viscosity, long resin tag
formation, and good marginal integrity with low microleakage.[7] However, the clinical comparison results are disparate and limited in number. A
study found a significantly higher retention rate for hydrophilic sealant compared
with a hydrophobic sealant.[8] A study in 2013 found the retention rate to be similar compared with a hydrophobic
sealant, but superior compared with a glass ionomer sealant.[6] Moreover, a study found that a hydrophilic sealant had a poorer retention performance
and surface quality.[9] According to its physical properties, a hydrophilic sealant has the potential to
overcome challenging clinical situations. This may be beneficial to the use of sealant
in less-than-ideal situations, such as the school-based sealant programs that are
commonly performed in a field setting that is a challenging clinical environment.
The aim of this study was to evaluate and compare the clinical retention rate between
hydrophilic resin-based sealant and hydrophobic resin-based sealant placed in a field
setting after 8 and 12 months. The associated factors related to material retention
were also assessed.
Materials and Methods
Sample Size Estimation
The McNemar's test of equality of paired proportions was applied considering that
the test is two-sided with a significance level of 0.05 and power of 80%. The proportion
of hydrophilic sealant was calculated at 80% in a similar study by Prabakar et al.[8] The expected proportion of the hydrophobic resin-based sealant was 70% according
to Tianviwat et al, which concluded a difference in the proportion of 10% between
both groups.[10] The proportion of discordant pairs was calculated at 14%. The calculation revealed
that a sample size of 96 pairs was required. By adding 10% as the possible drop-out
rate, the sample size was finalized at 106 pairs.
Inclusion and Exclusion Criteria
The inclusion criteria were healthy, cooperative 6 to 9-year-old participants with
bilateral fully erupted permanent first molars with deep pits and fissures and the
same carious condition. The included molars were sound to noncavitated distinct visual
change in enamel lesions or graded as 0, 1, or 2 according to the International Caries
Detection and Assessment System (ICDAS).
Patients who did not fully cooperate throughout the procedure on both teeth along
with teeth with enamel defects, proximal carious lesions, or restorations were excluded
from the study.
Sample Recruitment
The samples were recruited from a list of over 298 early elementary students in three
public schools who were already participating in the school-based sealant program.
The dental check-up was performed at school by a dental nurse. Informed consent was
provided by the parents of the eligible participants.
Clinical Procedure
This study was a prospective, randomized controlled with a split-mouth design. It
was conducted in a field setting. This study protocol was approved by an Institutional
Review Board (COA.No.MU-DT/PY-IRB 2021/024.2202). This study was registered in the
Clinical Trial Registry (identification number: TCTR20230412003).
A total of 106 pairs of teeth were included and one tooth in each pair was assigned
into two groups, hydrophobic or hydrophilic sealant, by computer-generated randomization.
Both materials were equally divided into left-side teeth and right-side teeth groups.
The randomization process was done again within each group to determine which side
of the arch the operator began applying the sealants. One half of the group, 26 pairs,
was assigned to have the operator start on the right side followed by the left side
and vice versa.
The operator was a skilled dental nurse who routinely conducted the school-based sealant
program in the area. The operator was blinded to the type of material and the order
in which the different materials were placed. The participants and the examiners who
assessed the outcomes were also blinded to this information. Due to the similar opaque,
slightly yellowish-white color of both materials, before and after polymerization,
were indistinguishable post-setting.
This study was performed in a field setting on a mobile dental unit with a mobile
saliva ejector. The sealant applications were performed by a single operator with
the same assistant at the same operatory. Every step of the procedure with a specific
time length was recorded by a research assistant using a digital timer.
The tooth was cleaned with a slow-speed rubber cup and pumice. The pumice was washed
out with a copious stream of water with a gentle probing action using a dental explorer
along the grooves to remove any remaining debris. Cotton rolls were placed on the
buccal and lingual vestibule of the lower tooth and the buccal vestibule for the upper
tooth. The tooth was dried with the triple syringe for 10 seconds to remove excess
water that might affect the concentration of the subsequent acid etching procedure.
The dried tooth was applied with either 37% phosphoric acid (Scotchbond Etchant, 3M-ESPE,
St. Paul, Minnesota, United States) or 35% phosphoric acid (Ultra-etch Etchant, Ultradent,
South Jordan, Utah, United States) for 20 seconds and rinsed with water for 20 seconds.
The isolation procedure was performed with a new set of cotton rolls and dried with
a triple syringe for 10 seconds. A fully dry surface without any visible film of moisture
was expected.
The material was handed to the operator according to the order of treatment. In Group
1 hydrophobic sealant, the tooth was applied with Concise white sealant (3M. EPSE,
St. Paul, Minnesota, United States). In Group 2, hydrophilic sealant, the tooth was
applied with UltraSeal XT hydro sealant (Ultradent Products, South Jordan, Utah, United
States). Both types of sealants were polymerized using an LED light-curing unit (Bluephase
Style Ivoclar Vivadent Schaan, Liechtenstein) for 20 seconds with the tip placed directly
over the applied surface. A dental explorer was used to probe along the grooves to
detect any voids or roughness of the surface and reapplied if needed. The occlusion
was tested by having the participants bite on articulating paper and adjusted with
a slow-speed polishing bur if needed. The participants rinsed their mouths after the
procedure was completed.
Recall and Evaluation
The participants were originally asked to come back for an evaluation at follow-up
periods of 6 and 12 months. Due to the pandemic lockdown, the follow-up periods were
shifted to 8 and 12 months. The examination was done using the same mobile unit and
lighting in the field setting. The process began with having the patient thoroughly
brush and rinse with 1% hydrogen peroxide per the protocol for reducing the risk of
coronavirus disease 2019 transmission. Two dentists who were blinded to the types
of sealants applied were recruited to examine the teeth. Calibration was done prior
to the recall dates. Recalibration of the two dentists on the recall dates was done
by re-examining 10 participants. The intrareliability within the same examiner was
tested by re-examining 10% of the participants. The tactile and visual examinations
were performed by inspecting the sealant appearance under mobile lighting and using
a dental explorer to glide along the grooves. The sealant quality was graded according
to Simonsen's criteria; fully retained, partial loss, and total loss sealant.[11]
In the fully retained group, the tooth presented with sealant on all primary grooves
and no need to reseal. In the partially retained group, the tooth retained some of
the material that was detected by a ledged margin indicating a dislodged bulk of material
or visual exposure of the previously sealed deep pits and fissures. In the total sealant
loss group, no evidence of sealant was detectable on any pits and fissures of the
tooth.
If at any time during the recall period the included teeth were found to need immediate
care, such as a progressing carious lesion or traumatic injury, the patients were
referred to receive the appropriate dental treatments. However, neither of these conditions
was found throughout this study.
Statistical Analysis
The intrareliability of each examiner was tested by re-examining 10% of the participants.
The Kappa statistic was calculated and accepted at Kappa more than 0.7. The inter-reliability
of the examiners was calibrated by re-examining 10 participants. The Kappa statistic
was accepted at Kappa more than 0.7.
The demographic data of the participants comprising sex, age, tooth type, and the
carious condition were collected as descriptive data. The outcomes were analyzed using
SPSS Statistics for Windows, Version 28.0. (SPSS Inc., Chicago, Illinois, United States).
The retention rate between groups was compared using McNemar's test. The correlation
of sealant retention and arch type or ICDAS score were analyzed using chi-squared
and Fisher's exact test. A p-value less than 0.05 was considered statistically significant.
Results
Sixty-six children with 106 pairs of teeth were recruited according to the inclusion
criteria. After 12 months of follow-up, one child dropped out due to relocation, thus,
65 children with 105 pairs of teeth completed this study. The 65 children (6–9 years
old) comprised 36 males (55.4%) and 29 females (44.6%) with an average age of 7.51
years old. The flow of the participants in this study is presented in [Fig. 1]. Sixty-one pairs of teeth were upper molars and 44 were lower molars. The type of
tooth arch and ICDAS score are shown in [Table 1] along with the equal distribution of materials on the left and right side of the
arch.
Fig. 1 Study flow diagram.
Table 1
Distribution of hydrophobic and hydrophilic resin-based sealant by arch type, side,
and ICDAS score
Group (n = 105 pairs/210 teeth)
|
Arch type (teeth)
|
Right/left (teeth)
|
ICDAS score (teeth)
|
|
Upper
|
Lower
|
Right
|
Left
|
0
|
1
|
2
|
Hydrophobic sealant
|
61
|
44
|
52
|
53
|
50
|
31
|
24
|
Hydrophilic sealant
|
61
|
44
|
53
|
52
|
50
|
31
|
24
|
Total
|
122
|
88
|
110
|
110
|
100
|
62
|
48
|
Abbreviation: ICDAS, International Caries Detection and Assessment System.
The intra- and inter-reliability of both examiners were in good agreement with Kappa
values of 0.84 and 0.81 for intra-reliability and 0.80 for inter-reliability.
The sealant retention after 8 and 12 months is demonstrated in [Table 2]. At the 8-month follow-up, the sealant retention rate in each retention category
between the two materials was not significantly different (p = 0.051). For the 12-month follow-up, a slightly increased frequency was found in
the partially retained and missing groups of both materials. However, there were no
significant differences in the sealant retention rate of the two materials (p = 0.140).
Table 2
The retention rate of hydrophobic and hydrophilic resin-based sealant at the 8- and
12-month follow-ups
Follow-up time (months)
|
Types of sealant
|
Retention, n (%)
|
p-Value
|
Fully retained
|
Partially retained
|
Total loss
|
8
|
Hydrophobic
|
87 (82.9)
|
16 (15.2)
|
2 (1.9)
|
0.051
|
Hydrophilic
|
74 (70.5)
|
28 (26.7)
|
3 (2.9)
|
12
|
Hydrophobic
|
84 (80)
|
18 (17.1)
|
3 (2.9)
|
0.140
|
Hydrophilic
|
72 (68.6)
|
29 (27.6)
|
4 (3.8)
|
McNemar's test.
The factors associated with the retention rates were distributed in [Table 3]. In both groups, the materials applied in lower arch showed a superior retention
rate compared with the materials on the upper arch (p < 0.05). However, the difference in ICDAS scores showed no relationship with the
retention rate in both groups.
Table 3
The correlation of sealant retention at 12-month follow-up between arch type and ICDAS
score
Sealant type/factors
|
Fully retained, n (%)
|
Partially retained, n (%)
|
Total loss, n (%)
|
Total, n (%)
|
p-Value
|
Hydrophobic sealant
|
Upper
|
43 (70.5)
|
15 (24.6)
|
3 (4.9)
|
61 (100)
|
0.009
|
Lower
|
41 (93.2)
|
3 (6.8)
|
0 (0.0)
|
44 (100)
|
Hydrophilic sealant
|
Upper
|
35 (57.4)
|
22 (36.1)
|
4 (6.6)
|
61 (100)
|
0.007
|
Lower
|
37 (84.1)
|
7 (15.9)
|
0 (0.0)
|
44 (100)
|
Hydrophobic sealant
|
ICDAS 0
|
36 (72)
|
12 (24)
|
2 (4)
|
50 (100)
|
0.149
|
ICDAS 1
|
29 (93.5)
|
2 (6.5)
|
0 (0.0)
|
31 (100)
|
ICDAS 2
|
19 (79.2)
|
4 (6.7)
|
1 (4.2)
|
24 (100)
|
Hydrophilic sealant
|
ICDAS 0
|
32 (64)
|
14 (28)
|
4 (8)
|
50 (100)
|
0.360
|
ICDAS 1
|
21 (67.7)
|
10 (32.3)
|
0 (0.0)
|
31 (100)
|
ICDAS 2
|
19 (79.2)
|
5 (20.8)
|
0 (0.0)
|
24 (100)
|
Abbreviation: ICDAS, International Caries Detection and Assessment System.
Chi-squared and Fisher's exact test.
Discussion
The objective of this study was to evaluate and compare the clinical retention rate
between a hydrophilic resin-based sealant and hydrophobic resin-based sealant placed
in a field setting after 8 and 12 months. This study was conducted in a field setting
with a mobile dental unit. The field setting was chosen to demonstrate the actual
dental treatment done in the school-based sealant program that has been performed
in Thailand for decades.[10]
[12]
The materials used in this study were UltraSeal XT hydro, which is commercially available
and Concise white sealant, which is one of the oldest and widely used conventional
resin-based sealants in Thailand's school-based sealant program. The hydrophilic resin
sealant was developed to address the moisture-sensitive nature of the hydrophobic
resin sealant. The hydrophobic bisphenol A-glycidyl methacrylate (bis-GMA) was replaced
with di-, tri-, and multifunctional acidic acrylate monomers. This formulation creates
a resin-based sealant that tolerates humidity and activates in the presence of moisture.[6]
In our designed field settings, the retention rate in the hydrophobic group was lower
than the expected performance of the hydrophobic resin-based sealant. The annual loss
of conventional hydrophobic resin-based sealant was reported to be 5 to 10%.[13] However, the retention rate of this group was higher than a study by Tianviwat et
al which reported that the average retention rate of sealant in Thailand's school-based
sealant program was 20 to 63% at a 1-year recall.[10] The hydrophobic sealant group at the 12-month recall demonstrated a 72% fully retained
rate, which aligned with a result of 73.1% from a study working in a clinical setting.[14]
This study was conducted using a split-mouth design. The different types of materials
were placed on two sides of the arch in the same patient. The advantage of this design
is the exclusion of the interindividual variability effect on the outcomes. The carry-across
effect, commonly found in the split-mouth design, did not apply to this study because
the materials were placed and fixed on a specific site. Although one type of sealant
used in this study released fluoride while the other did not, a study found that fluoride
release did not affect sealant retention.[2]
[3]
[11]
The recall period of this study was originally planned to be after 6 and 12 months.
Studies indicated that sealant failure was mostly found immediately after application
and at the 6-month follow-up.[9]
[11] However, due to the severe acute respiratory syndrome coronavirus 2 pandemic, the
research location was under a long lockdown period. Access to the participants and
research facility was not possible. Therefore, the recall period was extended to 8
months.
The field setting is a nonideal dental setting that can present problems during the
critical steps of dental treatment.[12] Sealant placement, whose clinical success depends on moisture control, can be affected
in this challenging setting. Moreover, the oral cavity is 100% humid by nature. Furthermore,
the school-based sealant program was done in elementary school students whose total
cooperation throughout the treatment cannot be expected. These factors are the possible
reasons for unsatisfactory retention rates, along with the inadequate number of dental
personnel.[12]
This study used cotton rolls together with a saliva ejector and triple syringe as
the moisture control procedure. The triple syringe was used for the same amount of
time in both material groups. Although the desiccated etching pattern of enamel was
observed after moisture control, the nonideal dental setting together with the humid
nature of the oral cavity suggests that some moisture could be present within the
fissures. These conditions favored the characteristic of hydrophilic sealant implying
that higher retention rate of the sealant might be expected. However, the retention
rate of hydrophilic and hydrophobic sealant is not significantly different. A similar
field setting study with different form of moisture control, that is, removing water
with cotton pallet to avoid desiccating the enamel, also found low retention rates
of hydrophilic sealant with only 10% of fully retained material at the 12-month recall.[15] A possible explanation might be that the optimum level of moisture is inapplicable
in practice. The manufacturer suggested that hydrophilic sealant works best on slightly
moist teeth. However, the ideal level of moisture that optimizes the adhesion strength
is challenging to replicate.
Sealants have the benefit of sealing and excluding the rough morphology of the pits
and fissures from the factors leading to dental caries development and caries progression.
Pit-and-fissure sealants provide primary prevention for sound teeth and secondary
prevention for teeth in which signs of decalcification are present. The material's
retention plays a critical role in clinical success because the protective barrier
is dependent on the material binding to the tooth surface. Because the commonly used
material is hydrophobic, moisture contamination jeopardizes sealant retention. Hydrophilic
materials were formulated to overcome the moisture sensitive process of sealant placement
and provide better retention. Our findings indicate that the hydrophilic resin-based
sealant (UltraSeal XT hydro) is similar to the conventional hydrophobic resin-based
sealant in maintaining the sealant on the tooth surface.
The retention rate of the materials on the lower arch group was significantly superior
to the upper arch group. However, the different arch contribution to the retention
rate of sealant is controversy.[16]
[17] This study conforms with a study by Ratnaditya et al that found higher retention
rate of sealants on the lower arch. The higher retention found in lower arch may be
from the easier access and direct visualized application of the sealant, the gravitation
force; moreover, the better-defined pit and fissure anatomy of mandibular molars may
also contribute to the outcomes.[17]
This study included the molars with baseline surface status ranging from ICDAS 0 to
2, sound surface to the early visual change without enamel breakdown. The retention
rate between different ICDAS scores demonstrated no significant difference after the
12-month recall. Another study found higher probability to fail in the early carious
lesions, ICDAS 1 to 3, than the sound surfaces, ICDAS 0.[18] However, it might be influenced from the different inclusion criteria with another
study's samples including ICDAS 3, the localized enamel breakdown without dentinal
involvement.[18]
Although the statistical analysis found no difference in the retention rates of the
two material types, the clinical significance of the outcomes was notable. The conventional
hydrophobic groups demonstrated higher retention rates compared with the hydrophilic
sealant at both recall periods, 8 and 12 months. Because the exact amount moisture
in favor of the hydrophilic sealant is still undetermined, replication of the profound
moisture level may yield a different result. This may provide a better understanding
of the material and indications for future research. Further studies are needed to
develop an alternative moisture control strategy for pit and fissure sealant treatment.
Conclusion
The hydrophilic resin-based sealant presented no significant different retention rate
at the 8- and 12-month recalls compared with the hydrophobic resin-based sealant under
field conditions.