Endoscopic nasobiliary drainage (ENBD) is a widely used technique for bile duct decompression.
It also provides access to the bile duct and allows cholangiography to be repeated.
After placement, the drainage tube is left exiting from the mouth and re-routing via
one of the nostrils is necessary. Conventionally, a nasopharyngeal tube, which is
used as a carrier, is advanced into the patient’s nose and into the posterior pharynx.
The endoscopist then retrieves the tip of the tube in the pharynx with his fingers
in the patient’s mouth. This step causes discomfort to the patient and puts the endoscopist
at risk of being bitten. A new method was reported recently using a pair of grasping
forceps to capture the carrier through an end-viewing scope [1]. This method requires, of course, the use of an end-viewing endoscope. We describe
here our novel method of extracting the carrier tube using a section of guide wire.
A 3 cm × 2 cm loop is made with a piece of guide wire (Jagwire; Boston Scientific
Corporation, Miami, FL, USA) and inserted into the patient’s oral cavity until it
touches the posterior wall of the pharynx ([Fig. 1]). The endoscopist then loosens the wire loop, allowing it to occupy the width of
the pharynx. A 16F soft nasopharyngeal tube is advanced through the nose down to the
pharynx. The tube can be easily trapped within the loop. When the wire is withdrawn,
it pulls the carrier with it out of the mouth ([Fig. 2]). A classical conversion is then performed to bring the drain out through the nose,
using the carrier as the guide ([Video 1]).
Fig. 1 A loop was made with a section of guide wire and inserted into patient’s mouth.
Fig. 2 The tip of the carrier was successfully extracted with the guide wire.
Video
1 A simple way to convert an orobiliary to a nasobiliary tube using a piece of guide
wire.
This method is quite simple and needs no additional accessories, as a used guide wire
is readily available when ENBD is performed. The endoscopist does not require special
training, and in our unit there is a more than 90 % success rate at the first attempt.
It takes only about 1 min to accomplish the conversion – much shorter than the traditional
way, which takes about 3–5 min. This method causes negligible discomfort to the patient
and can be used when the patient is under conscious sedation even with the teeth-guard
in situ. This novel technique is a simple, safe, convenient and time-saving method
to convert an orobiliary to a nasobiliary tube.
Endoscopy_UCTN_Code_TTT_1AR_2AK