Endoscopy 2018; 50(10): 1022-1026
DOI: 10.1055/a-0582-9127
Innovations and brief communications
© Georg Thieme Verlag KG Stuttgart · New York

Safety of lumen-apposing stent with or without coaxial plastic stent for endoscopic ultrasound-guided drainage of pancreatic fluid collections: a retrospective study

Manuel Puga
1   Department of Digestive Diseases, Complexo Hospitalario Universitario de Ourense, Ourense, Spain
2   Endoscopy Unit, Department of Digestive Diseases, Hospital Universitari de Bellvitge, Bellvitge Biomedical Research Institute (IDIBELL), University of Barcelona, Barcelona, Spain
,
Claudia F. Consiglieri
2   Endoscopy Unit, Department of Digestive Diseases, Hospital Universitari de Bellvitge, Bellvitge Biomedical Research Institute (IDIBELL), University of Barcelona, Barcelona, Spain
,
Juli Busquets
3   Department of Surgery, Hospital Universitari de Bellvitge, Bellvitge Biomedical Research Institute (IDIBELL), University of Barcelona, Barcelona, Spain
,
Natàlia Pallarès
4   Statistics Advisory Service, Bellvitge Biomedical Research Institute (IDIBELL), Barcelona, Spain
,
Lluis Secanella
3   Department of Surgery, Hospital Universitari de Bellvitge, Bellvitge Biomedical Research Institute (IDIBELL), University of Barcelona, Barcelona, Spain
,
Nuria Peláez
3   Department of Surgery, Hospital Universitari de Bellvitge, Bellvitge Biomedical Research Institute (IDIBELL), University of Barcelona, Barcelona, Spain
,
Joan Fabregat
3   Department of Surgery, Hospital Universitari de Bellvitge, Bellvitge Biomedical Research Institute (IDIBELL), University of Barcelona, Barcelona, Spain
,
José Castellote
5   Hepatology Unit, Department of Digestive Diseases, Hospital Universitari de Bellvitge, Bellvitge Biomedical Research Institute (IDIBELL), University of Barcelona, Barcelona, Spain
,
Joan B. Gornals
2   Endoscopy Unit, Department of Digestive Diseases, Hospital Universitari de Bellvitge, Bellvitge Biomedical Research Institute (IDIBELL), University of Barcelona, Barcelona, Spain
› Author Affiliations
Further Information

Publication History

submitted 01 November 2017

accepted after revision 30 January 2018

Publication Date:
28 March 2018 (online)

Preview

Abstract

Background The aim of this study was to evaluate whether the placement of a coaxial double-pigtail plastic stent (DPS) within a lumen-apposing metal stent (LAMS) may improve the safety of endoscopic ultrasound (EUS)-guided drainage of pancreatic fluid collections (PFCs).

Methods This was a retrospective cohort study including patients with PFCs and an indication for transmural drainage. Two strategies (LAMS alone or LAMS plus DPS) were used at the endoscopist’s discretion.

Results A total of 41 patients were treated (21 LAMS alone; 20 LAMS plus DPS). The characteristics of the PFCs, and the technical and clinical success rates did not differ between groups. The LAMS alone group had a significantly higher rate of adverse events than the LAMS plus DPS group (42.9 % vs. 10.0 %; P = 0.04). Bleeding was the most frequent adverse event observed.

Conclusions The addition of a coaxial DPS to LAMS was associated with a lower rate of adverse events in EUS-guided drainage of PFCs.

Supplementary Fig. e3 and Supplementary Table e2