Zentralbl Chir 2019; 144(01): 44-49
DOI: 10.1055/a-0788-9533
Originalarbeit
Georg Thieme Verlag KG Stuttgart · New York

Die doppelreihig fortlaufende Nahtversorgung von primären Nabelhernien – Analyse eines Versorgungskonzeptes nach 282 Fällen

Double Running Suture Line Repair in Primary Umbilical Hernias – Analysis after 282 Cases
Joachim Wilfried Heise
Klinik für Allgemein-, Viszeral- und Schilddrüsenchirurgie, BETHLEHEM Gesundheitszentrum Stolberg gGmbH, Deutschland
,
Joseph Magloire Ewodo Beyeme
Klinik für Allgemein-, Viszeral- und Schilddrüsenchirurgie, BETHLEHEM Gesundheitszentrum Stolberg gGmbH, Deutschland
,
Josef Tomczak
Klinik für Allgemein-, Viszeral- und Schilddrüsenchirurgie, BETHLEHEM Gesundheitszentrum Stolberg gGmbH, Deutschland
,
Nermin Tosuncuk Ari
Klinik für Allgemein-, Viszeral- und Schilddrüsenchirurgie, BETHLEHEM Gesundheitszentrum Stolberg gGmbH, Deutschland
› Author Affiliations
Further Information

Publication History

Publication Date:
18 December 2018 (online)

Zusammenfassung

Einleitung Es besteht fortgesetzt ein Entscheidungskonflikt, welche Nabelhernienpatienten allein durch Naht oder eben mit einer Netzverstärkung operiert werden sollen. Nach überwiegender Anwendung einer doppelreihig fortlaufenden Nahttechnik mit nicht resorbierbarem Faden über einen langen Zeitraum im eigenen Patientengut war das Ziel der vorliegenden Studie, die Leistungsfähigkeit dieser Strategie auch in Fällen mit größeren Bruchlücken zu überprüfen.

Patienten und Methoden Nach Extraktion aller fallbezogenen Dokumente von operierten Nabelbruchpatienten wie OP- und Entlassbericht, Narkoseprotokoll und Verlaufsbogen aus dem Krankenhausinformationssystem (KIS) erfolgte die exakte Erfassung der analyserelevanten Parameter in einer Datenbank (FileMaker® 12.0). Doppelreihig fortlaufend nahtversorgte erwachsene Patienten (≥ 18 J), ausgeschlossen Rezidiv- und Begleiteingriffe, mit Nabellücken ≤ 2 cm (Gruppe [Gr.] 1) wurden solchen mit Defekten > 2 cm (Gruppe [Gr.] 2) gegenübergestellt. Langzeitergebnisse wurden aus dem KIS, durch Nachuntersuchung, Fragebogenversand und Telefoninterviews erhoben. Zur Signifikanztestung wurden Mann-Whitney-U- und Chi-Quadrat-Test angewandt bei einem Signifikanzniveau von p < 0,05.

Ergebnisse Vom 1.1.2004 bis 31.3.2017 wurden zunächst n = 515 Nabelhernieneingriffe detektiert. Von 282 Patienten mit primärer Nabelbruchoperation in Form einer doppelreihigen fortlaufenden Naht kamen nur Fälle mit Nachuntersuchungsergebnissen zur Auswertung (n = 216). Die Patienten in Gr. I (n = 147) waren im Median im Vergleich zu Gr. II (n = 69) jünger (51 vs. 54 Jahre; p = 0,0012), leichter (BMI: 29 vs. 33; p = 0,003) und tendenziell weniger krank (ASA: 2 vs. 2; p = 0,0837). Die Komplikationsrate war mit 8/147 (5%) zu 4/69 (6%; p = 0,9154) nicht signifikant unterschiedlich. Die Rezidivrate nach einer Nachbeobachtungszeit von im Median 4,6 Jahren betrug von 6/147 (4%) zu 4/69 (6%; p = 0,5759).

Schlussfolgerung Die konsequente Anwendung einer doppelreihig fortlaufenden nicht resorbierbaren Naht erzielt gute Ergebnisse in der Versorgung von Nabelhernien. Die Resultate der durchgeführten Studie lassen in einem uniform so versorgten Kollektiv den Schluss zu, dass auch ältere und durchschnittlich schwerere Patienten mit Nabelhernien > 2 cm sicher mit dieser Nahttechnik versorgt werden können.

Abstract

Introduction There is an ongoing debate as to which patients presenting with an umbilical hernia should be operated with the sole suture technique or augmented by mesh. After treating most of our patients for a long period uniformly with a double running suture line, the aim of this study was to evaluate the performance of this strategy – especially in patients with larger defects.

Patients and Methods From 1/2004 to 4/2017, all patients operated on for an umbilical hernia were identified through our hospital information system (KIS). The relevant documents for each case – such as operation and discharge reports, anaesthesia protocol, and information on the clinical course were extracted and the critical parameters entered into a database program (FileMaker® 12.0). Adult patients (≥ 18 y) with a double running suture line, excluding recurrences and surgery simultaneously to minimally invasive interventions, receiving surgery on umbilical defects ≤ 2 cm (size 1) were compared to those with defects > 2 cm (size 2). Long-time results were gathered from the KIS, follow-up investigations, questionnaires and telephone interviews. Chi-square and Mann-Whitney U tests were applied; p < 0.05 was considered significant.

Results 515 operations for umbilical hernias were identified, of which 282 were primary cases with double running suture. The follow-up was 77%. Only cases with follow-up information were considered. Patients with size 1 (n = 147) were significantly younger than patients with size 2 (n = 69; 51 vs. 54 years; p = 0.0012), had a lower BMI (29 vs. 33; p = 0.003) and tended to have lower ASA score (2 vs. 2; p = 0.0837). Complications were seen in 8/147 (5%) vs. 4/69 (6%) cases, respectively (p = 0.9174). The recurrence rate after a median of 4,6 years was in 6/147 in size 1 (4%) vs. 4/69 (6%) in size 2 (p = 0.5759).

Conclusion The use of a double running suture line with non-absorbable material with umbilical hernias led to good results in our patients. Repair of primary umbilical hernias was mostly successful, independently of the size of the defect, even in older patients with greater body weight.

 
  • Literatur

  • 1 Aslani N, Brown CJ. Does mesh offer an advantage over tissue in the open repair of umbilical hernias? A systematic review and meta-analysis. Hernia 2010; 14: 455-462
  • 2 Winsnes A, Haapamäki MM, Gunnarsson U. et al. Surgical outcome of mesh and suture repair in primary umbilical hernia: postoperative complications and recurrence. Hernia 2016; 20: 509-516
  • 3 Nguyen MT, Berger RL, Hicks SC. et al. Comparison of outcomes of synthetic mesh vs. suture repair of elective primary ventral herniorrhaphy: a systematic review and meta-analysis. JAMA Surg 2014; 149: 415-421
  • 4 Christoffersen MW, Helgstrand F, Rosenberg J. et al. Lower reoperation rate for recurrence after mesh versus sutured elective repair in small umbilical and epigastric hernias. A nationwide register study. World J Surg 2013; 37: 2548-2552
  • 5 Arroyo A, García P, Pérez F. et al. Randomized clinical trial comparing suture and mesh repair of umbilical hernia in adults. Br J Surg 2001; 88: 1321-1323
  • 6 Kaufmann R, Halm JA, Eker HH. et al. Mesh versus suture repair of umbilical hernia in adults: a randomised, double-blind, controlled, multicentre trial. Lancet 2018; 391: 860-869
  • 7 Lorenz R, Koch A, Köckerling F. et al. Doch unterschätzt – Nabel- und epigastrische Hernien. Herniamed-Datenanalyse 2009 bis 2014. CHAZ 2014; 15: 408-411
  • 8 Mayo WJ. VI. An operation for the radical cure of umbilical hernia. Ann Surg 1901; 34: 276-280
  • 9 Schumacher OP, Peiper C, Lörken M. et al. Langzeitergebnisse der Nabelhernienreparation nach Spitzy. Chirurg 2003; 74: 50-54
  • 10 Tunio NA. Hernioplasty: tension free mesh repair versus Mayos repair for umbilical hernias. J Pak Med Assoc 2017; 67: 24-26
  • 11 Yıldız I, Koca YS. A new approach to umbilical hernia repair: the circular suture technique for defects less than 2 cm. Ann Ital Chir 2017; 6: 449-453
  • 12 van den Heuvel B, van Jarwaarde JA, Wichers P. et al. Follow-up after laparoscopic inguinal hernia repair, can it be done by phone? A prospective study in 300 patients, the PINQ-PHONE. Surg Endosc 2015; 29: 3292-3297
  • 13 Schumpelick V, Arlt G, Klinge U. Hernienchirurgie – Versorgung von Nabelhernie und Narbenhernie. Dtsch Ärztebl 1997; 94: A-3471-3476
  • 14 Dalenbäck J, Andersson C, Ribokas D. et al. Long-term follow-up after elective adult umbilical hernia repair: low recurrence rates also after non-mesh repairs. Hernia 2013; 17: 493-497
  • 15 Israelsson LA, Jonsson T. Suture length to wound length ratio and healing of midline laparotomy incisions. Br J Surg 1993; 80: 1284-1286
  • 16 Cooney GM, Kiernan A, Winter DC. et al. Optimized wound closure using a biomechanical abdominal model. Br J Surg 2018; 105: 395-400
  • 17 Henriksen NA, Deerenberg EB, Venclauskas L. et al. Meta-analysis on materials and techniques for laparotomy closure: the MATCH review. World J Surg 2018; 42: 1666-1678
  • 18 Köckerling F, Koch A, Adolf D. et al. Has Shouldice repair in a selected group of patients with inguinal hernia comparable results to Lichtenstein, TEP and TAPP techniques?. World J Surg 2018; 42: 2001-2010
  • 19 Muschaweck U. Umbilical and epigastric hernia repair. Surg Clin North Am 2003; 83: 1207-1221
  • 20 Berger RL, Li LT, Hicks SC. et al. Suture versus preperitoneal polypropylene mesh for elective umbilical hernia repairs. J Surg Res 2014; 192: 426-431
  • 21 Köhler G, Luketina RR, Emmanuel K. Sutured repair of primary small umbilical and epigastric hernias: concomitant rectus diastasis is a significant risk factor for recurrence. World J Surg 2015; 39: 121-126
  • 22 Coelho JC, Claus CM, Campos AC. et al. Umbilical hernia in patients with liver cirrhosis: a surgical challenge. World J Gastrointest Surg 2016; 27: 476-482
  • 23 Shankar DA, Itani KMF, OʼBrien WJ. et al. Factors associated with long-term outcomes of umbilical hernia repair. JAMA Surg 2017; 152: 461-466