Int J Sports Med 2011; 32(04): 281-286
DOI: 10.1055/s-0030-1269915
Orthopedics & Biomechanics

Injuries Restored to ROM Using PSWD and Mobilizations

D.O. Draper
BYU, EX SCI, Provo, United States
› Author Affiliations

Abstract

The purpose of this paper is to report the cases of 7 subjects who lacked full range of motion (ROM) in the elbow, and my treatment regimen of PSWD and joint mobilizations. 7 subjects presented with decreased elbow (ROM) due to extensive fractures and or dislocations from traumatic injuries. All subjects were post-surgical, 2 with internal fixation devices. Initial active extension for each patient was 17°, 23°, 28°, 25°, 45°, 30°, 26° respectively (range of 17–45 degrees). Treatment regimen consisted of PSWD to the anterior elbow for 20 min at 48 watts. Immediately after PSWD, mobilizations were administered to the elbow. Extension improved 19°, 21°, 25°, 23°, 20°, 30°, and 26°, respectively, after 6 or less treatments (range of 19–30 degrees). All but 1 patient returned to normal activities with functional ROM in all planes. Follow-up 4 weeks later indicated that all of the subjects maintained 85–100% of their extension. No negative effects were reported during the short-term follow-up. When precautions are taken, I propose PSWD (48 W) may be an appropriate adjunct to joint mobilizations to increase ROM in peripheral joints despite implanted metal.



Publication History

Received: 2010

Accepted after revision: 22 November 2010

Publication Date:
04 March 2011 (online)

© Georg Thieme Verlag KG Stuttgart · New York

 
  • References

  • Abranson DI. Indirect vasodilation in thermotherapy. Arch Phys Med Rehabil 1965; 46: 412-415
  • Benson TB, Copp EB. The effects of therapeutic forms of heat and ice on the pain threshold of the normal shoulder. Rheumatol Rehabil 1974; 13: 101-104
  • Crockford GW, Hellon RF, Parkhouse J. Thermal vasomotor response in human skin semiated by local mechanisms. J Physiol 1962; 161: 10-15
  • Currier DP, Kramer JF. Sensory nerve conduction: heating effects of ultrasound and infrared radiation. Physiother Canada 1982; 34: 241-246
  • Fox HH, Hill SM. Bradykinin formation in human skin as a factor in heat vasodilation. J Physiol 1958; 142: 219
  • Draper DO, Castel JC, Castel D. Low-watt pulsed shortwave diathermy and metal plate fixation of the elbow. Athletic Therapy Today 2004; 9: 28-32
  • Draper DO, Castel JC, Castel D. Rate of temperature increase in human muscle during 1 MHZ and 3 MHZ continuous ultrasound. J Orthop Sports Phys Ther 1995; 22: 142-150
  • Draper DO, Harris ST, Schulthies SS, Ricard MD, Knight KK, Durrant E. Hotpack and 1 MHz ultrasound treatments have an additive effect on muscle temperature increase. J Athl Train 1998; 33: 21-24
  • Draper DO, Knight KL, Fujiwara T, Castel JC. Temperature change in human muscle during and after pulsed short-wave diathermy. Orthop Sports Phys Ther 1999; 29: 13-22
  • Ducker H. The effects of metal on short-wave field distribution. Physiotherapy 1968; 54: 244-246
  • Gajdosik RL, Bohannon RW. Clinical measurement of range of motion: review of goniometry emphasizing reliability and validity. Phys Ther 1987; 67: 1867-1872
  • Garrett CL, Draper DO, Knight KL. Heat distribution in the lower leg from pulsed short-wave diathermy and ultrasound treatments. J Athl Train 2000; 35: 50-55
  • Greenman PE. Principles of Manual Medicine. 2nd ed Baltimore: Williams & Wilkins; 1996
  • Harriss DJ, Atkinson G. International Journal of Sports Medicine – Ethical Standards in Sport and Exercise Science Research. Int J Sports Med 2009; 30: 701-702
  • Hecox B, Mohrotoab TA, Weisberg J. Physical Agents: A Comprehensive Text for Physical Therapists. CT.: Simon & Schuster; 1994: 159
  • Kaltenborn FM. Manual Mobilization of the Joints — The Kaltenborn Method of Joint Examination and Treatment. Vol 1, (6th ed) Oslo: Olaf Norlis Bokhandel; 2002
  • Kitchen S, Partridge C. Review of shortwave diathermy continuous and pulsed patterns. Physiotherapy 1992; 78: 243-252
  • Knight KL, Draper DO. Therapeutic Modalities: The Art and Science. Baltimore, MD: Wolters Kluwer/Lippincott Williams & Wilkins; 2007: 285
  • Leadbetter WB, Buckwalter JA, Gordon SL. (eds) American Orthopaedic Society for Sports Medicine Symposium. Sports-Induced Inflammation: Clinical and Basic Science Concepts. Park Ridge, IL: American Academy of Orthopaedic Surgeons; 1990
  • Lehmann JF, Masock AJ, Warren CG, Koblanski JN. Effect of therapeutic temperatures on tendon extensibility. Arch Phys Med Rehabil 1970; 51: 481-487
  • Lehmann JF, McDougall JA, Guy AW, Warren CG, Esselman PC. Heating patterns produced by shortwave diathermy applicators in tissue substitute models. Arch Phys Med Rehabil 1983; 64: 575-577
  • Low JL. The reliability of joint measurement. Physiotherapy 1976; 62: 227-229
  • Maitland GD. Peripheral Manipulation. 3rd ed Oxford: Butterworth-Heinemann; 1991
  • McCray RE, Patton NJ. Pain relief at trigger points: a comparison of moist heat and shortwave diathermy. J Ortho Sport Phys Ther 1984; 5: 175-178
  • Michlovitz SL, Nolan TP. Modalities for Therapeutic Intervention. 4th ed Philadelphia: F.A. Davis; 2005: 91
  • Murray CC, Kitchen S. Effect of pulse repetition rate on the perception of thermal sensation with pulsed shortwave diathermy. Physiother Res Int 2000; 5: 73-85
  • Oosterveld FGJ, Rasker JJ, Jacobs JWG, Overmars HJA. The effect of local heat and cold therapy on the intraarticular and skin surface temperature of the knee. Arthritis Rheum 1992; 35: 146-151
  • Reid RW, Foley JM, Prior BM, Weingand KW, Meyer RA. Mild topical heat increases popliteal blood flow as measured by MRI. Med Sci Sports Exerc 1999; 3
  • Rothstein JM, Miller PJ, Roettger RF. Goniometric reliability in a clinical setting: Elbow and knee measurements. Phys Ther 1983; 63: 1611-1615
  • Ruggera PS, Witters DM, von Maltzahn G, Bassen HI. In vitro assessment of tissue heating near metallic medical implants by exposure to pulsed radio frequency diathermy. Phys Med Biol 2003; 48: 2919-2928
  • Scott BO. The effects of metal on short-wave field distribution. Ann Phys Med 1953; 1: 238-244
  • Seiger C, Draper DO. Use of pulsed shortwave diathermy and joint mobilizations to increase ankle range of motion in the presence of surgical implanted metal: A case series. J Orthop Sports Phys Ther 2006; 36: 669-677
  • Sekins KM, Lehmann JF, Esselman P, Dundore D, Emery AF, deLateur BJ, Nelp WB. Local muscle blood flow and temperature responses to 915 MHz diathermy as simultaneously measured and numerically predicted. Arch Phys Med Rehabil 1984; 65: 1-7
  • Shields N, O’Hare H, Gormley J. Contraindications to shortwave diathermy: survey of Irish physiotherapists. Physiotherapy 2004; 90: 42-53
  • Valtonen EJ, Lilius HG, Tiula E. Disturbances in the function of cardiac pacemaker caused by shortwave and microwave diathermies and pulsed high frequency current. Ann Chir Gyn Fenn 1975; 64: 284-287