Facial Plast Surg 2014; 30(05): 581-586
DOI: 10.1055/s-0034-1393697
Rapid Communication
Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

Use of Copolymer Polylactic and Polyglycolic Acid Resorbable Plates in Repair of Orbital Floor Fractures

Jonathan Lin
1   Department of Otolaryngology-Head and Neck Surgery, Irvine School of Medicine, University of California, Irvine, California
,
Michael German
2   Department of Otolaryngology-Head and Neck Surgery, Central Coast Head and Neck Surgeons, St. Monterey, California
,
Brian Wong
1   Department of Otolaryngology-Head and Neck Surgery, Irvine School of Medicine, University of California, Irvine, California
3   Department of Otolaryngology-Head and Neck Surgery, Beckman Laser Institute and Medical Clinic, University of California, Irvine, California
› Author Affiliations
Further Information

Publication History

Publication Date:
14 November 2014 (online)

Abstract

The fractures of the orbital floor are common after craniofacial trauma. Repair with resorbable plates is a viable reconstructive option; however, there are few reports in the literature. This study describes our experience using copolymer polylactic and polyglycolic acid (PLLA/PGA) orbital reconstruction plates (LactoSorb, Lorenz Surgical, Jacksonville, FL) in 29 cases of the orbital floor fracture repair. We conducted a retrospective review of 29 orbital floor fractures at a single institution repaired through transconjunctival, preseptal dissection using PLLA/PGA plates fashioned to repair the orbital floor defect. Associated fractures included zygomaticomaxillary, LeFort, and nasoethmoid fractures. There were six patients with complications. Four patients had transient diplopia with complete resolution of symptoms within 1 year. One patient had diplopia postoperatively, but was later lost to follow-up. Two patients have had persistent enophthalmos since 1 year. In each of these cases, the floor fracture was coincident with significant panfacial or neurotrauma. We did not encounter any adverse inflammatory reactions to the implant material itself. The study concluded that orbital floor fracture repair with resorbable plates is safe, relatively easy to perform, and in the majority of cases was effective without complications. In the presence of severe orbital trauma, more rigid implant materials may be appropriate.

 
  • References

  • 1 Kuhn F, Pieramici D. Ocular Trauma: Principles and Practice. New York, NY: Thieme; 2002: 385-388
  • 2 Clodius LB. Leatherbarrow. Oculoplastic Surgery. London: Dunitz; 2002: 156-157
  • 3 Alinasab B, Ryott M, Stjärne P. Still no reliable consensus in management of blow-out fracture. Injury 2014; 45 (1) 197-202
  • 4 Krishnan V, Johnson JV. Orbital floor reconstruction with autogenous mandibular symphyseal bone grafts. J Oral Maxillofac Surg 1997; 55 (4) 327-330 , discussion 330–332
  • 5 Chowdhury K, Krause GE. Selection of materials for orbital floor reconstruction. Arch Otolaryngol Head Neck Surg 1998; 124 (12) 1398-1401
  • 6 Celiköz B, Duman H, Selmanpakoğlu N. Reconstruction of the orbital floor with lyophilized tensor fascia lata. J Oral Maxillofac Surg 1997; 55 (3) 240-244
  • 7 Gunarajah DR, Samman N. Biomaterials for repair of orbital floor blowout fractures: a systematic review. J Oral Maxillofac Surg 2013; 71 (3) 550-570
  • 8 Enislidis G, Pichorner S, Kainberger F, Ewers R. Lactosorb panel and screws for repair of large orbital floor defects. J Craniomaxillofac Surg 1997; 25 (6) 316-321
  • 9 Persons BL, Wong GB. Transantral endoscopic orbital floor repair using resorbable plate. J Craniofac Surg 2002; 13 (3) 483-488 , discussion 488–489
  • 10 Eppley BL, Morales L, Wood R , et al. Resorbable PLLA-PGA plate and screw fixation in pediatric craniofacial surgery: clinical experience in 1883 patients. Plast Reconstr Surg 2004; 114 (4) 850-856 , discussion 857
  • 11 Hollier LH, Rogers N, Berzin E, Stal S. Resorbable mesh in the treatment of orbital floor fractures. J Craniofac Surg 2001; 12 (3) 242-246
  • 12 Uygur S, Cukurluoglu O, Ozmen S, Guclu TH, Sezgin B. Resorbable mesh plate in the treatment of blow-out fracture might cause gaze restriction. J Craniofac Surg 2009; 20 (1) 71-72
  • 13 Tong L, Bauer RJ, Buchman SR. A current 10-year retrospective survey of 199 surgically treated orbital floor fractures in a nonurban tertiary care center. Plast Reconstr Surg 2001; 108 (3) 612-621
  • 14 Motamedi MHK. An assessment of maxillofacial fractures: a 5-year study of 237 patients. J Oral Maxillofac Surg 2003; 61 (1) 61-64
  • 15 Shere JL, Boole JR, Holtel MR, Amoroso PJ. An analysis of 3599 midfacial and 1141 orbital blowout fractures among 4426 United States Army Soldiers, 1980–2000. Otolaryngol Head Neck Surg 2004; 130 (2) 164-170
  • 16 Rosado P, de Vicente JC. Retrospective analysis of 314 orbital fractures. Oral Surg Oral Med Oral Pathol Oral Radiol 2012; 113 (2) 168-171 PubMed
  • 17 Suga H, Sugawara Y, Uda H, Kobayashi N. The transconjunctival approach for orbital bony surgery: in which cases should it be used?. J Craniofac Surg 2004; 15 (3) 454-457
  • 18 Tan Başer N, Bulutoğlu R, Celebi NU, Aslan G. Clinical management and reconstruction of isolated orbital floor fractures: the role of computed tomography during preoperative evaluation. Ulus Travma Acil Cerrahi Derg 2011; 17 (6) 545-553
  • 19 Burnstine MA. Clinical recommendations for repair of isolated orbital floor fractures: an evidence-based analysis. Ophthalmology 2002; 109 (7) 1207-1210 , discussion 1210–1211, quiz 1212–1213
  • 20 Hawes MJ, Dortzbach RK. Surgery on orbital floor fractures. Influence of time of repair and fracture size. Ophthalmology 1983; 90 (9) 1066-1070
  • 21 Brucoli M, Arcuri F, Cavenaghi R, Benech A. Analysis of complications after surgical repair of orbital fractures. J Craniofac Surg 2011; 22 (4) 1387-1390
  • 22 Ng JD, Huynh TH, Burgett R. Complications of bioabsorbable orbital implants and fixation plates. Ophthal Plast Reconstr Surg 2004; 20 (1) 85-86
  • 23 Tuncer S, Yavuzer R, Kandal S , et al. Reconstruction of traumatic orbital floor fractures with resorbable mesh plate. J Craniofac Surg 2007; 18 (3) 598-605
  • 24 Wiltfang J, Merten HA, Becker HJ, Luhr HG. The resorbable miniplate system Lactosorb in a growing cranio-osteoplasty animal model. J Craniomaxillofac Surg 1999; 27 (4) 207-210