J Reconstr Microsurg 2018; 34(04): 270-276
DOI: 10.1055/s-0037-1621727
Original Article
Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

Histological Changes in the Rat Femoral Artery Following the Use of the Empty-and-Refill Test

Alexandra Naides
1   Department of Orthopedic Surgery, Columbia University, New York, New York
,
Roberto Noland
1   Department of Orthopedic Surgery, Columbia University, New York, New York
,
Jiajie G. Lu
2   Department of Pathology and Cell Biology, Columbia University, New York, New York
,
Yelena Akelina
1   Department of Orthopedic Surgery, Columbia University, New York, New York
,
Charles Marboe
2   Department of Pathology and Cell Biology, Columbia University, New York, New York
,
Robert J. Strauch
1   Department of Orthopedic Surgery, Columbia University, New York, New York
› Author Affiliations
Further Information

Publication History

07 August 2017

18 November 2017

Publication Date:
22 January 2018 (online)

Abstract

Background This study examines the effects of the empty-and-refill patency test on rat femoral arteries in the longer postoperative time period.

Methods A simple arterial anastomosis was performed bilaterally on 20 rats. The empty-and-refill test was performed unilaterally in all rats, leaving the contralateral artery as an internal control. Rats were divided into two cohorts of 10 rats and survived for 48 hours and 2 weeks. Vessel patency was assessed prior to closing and immediately prior to sacrifice. The femoral arteries were harvested bilaterally and hematoxylin and eosin stains were performed. The femoral artery distal to the anastomosis in the region of the empty-and-refill test was histologically evaluated.

Results All vessels were patent at the time of sacrifice. There was no statistical difference in the numeric scoring between the experimental and control vessels in the 48-hour cohort. Almost all vessels harvested at 48 hours showed endothelial cell loss distal to the anastomosis regardless of whether they underwent the empty-and-refill test. The only statistically significant difference in the 2-week cohort was an increase in adventitial smooth muscle proliferation in the experimental group. There were no other statistically significant results between the experimental and control groups at 2 weeks. An overall comparison of both cohorts revealed a statistically significant increase in endothelial cell number and intimal proliferation by 2 weeks postsurgery.

Conclusion The empty-and-refill test does not compromise rat femoral artery anastomotic patency, nor does it produce histological damage either 48 hours or 2 weeks postsurgery.

 
  • References

  • 1 Hayhurst JW, O'Brien BM. An experimental study of microvascular technique, patency rates and related factors. Br J Plast Surg 1975; 28 (02) 128-132
  • 2 Varshney M. Essential Orthopedics. 1st ed. Jamshedpur: JP Medical Ltd; 2016: 1917
  • 3 Hunt T, Wiesel S. Operative Techniques in Hand, Wrist, and Forearm Surgery. 1st ed. Philadelphia: Wolters Kluwer Health/Lippincott Williams & Wilkins; 2011: 811-812
  • 4 Guvercin E, Yesiloglu N, Sirinoglu H, Sarici M. Utilization of postanastomotic side branches for the assessment of anastomotic patency. J Reconstr Microsurg 2015; 31 (03) 239
  • 5 Girman P, Kriz J, Balaz P. Rat Experimental Transplantation Surgery. 1st ed. Switzerland: Springer International Publishing; 2015: 60-61
  • 6 Pandya AN, Vaingankar N, Grant I, James NK. End-to-side venous anastomoses....a patency test. Br J Plast Surg 2003; 56 (08) 810-811
  • 7 Yonekawa Y, Frick R, Roth P, Taub E, Imhof H. Laboratory training in microsurgical techniques and microvascular anastomosis. Operat Tech Neurosurg 1999; 2 (03) 149-158
  • 8 Neligan P, Gurtner G. Plastic Surgery. 3rd ed. London: Elsevier/Saunders; 2013: 607-608
  • 9 Radad K, El-Shazly M. Clinical and pathological assessment of different suture techniques for microvascular anastomosis in rat femoral artery. J Vet Sci 2007; 8 (03) 269-273
  • 10 Siemionow M. Plastic and Reconstructive Surgery. 1st ed. London: Springer London; 2015: 17-19
  • 11 Huang Y, Tong D, Zhu S. , et al. Evaluation of microvascular anastomosis using real-time, ultra-high-resolution, Fourier domain Doppler optical coherence tomography. Plast Reconstr Surg 2015; 135 (04) 711e-720e
  • 12 Freed D, Hartley CJ, Christman KD, Lyman RC, Agris J, Walker WF. High-frequency pulsed Doppler ultrasound: a new tool for microvascular surgery. J Microsurg 1979; 1 (02) 148-153
  • 13 Shaughness G, Blackburn C, Ballestín A, Akelina Y, Ascherman JA. Predicting thrombosis formation in 1-mm-diameter arterial anastomoses with transit-time ultrasound technology. Plast Reconstr Surg 2017; 139 (06) 1400-1405
  • 14 Hecht N, Woitzik J, König S, Horn P, Vajkoczy P. Laser speckle imaging allows real-time intraoperative blood flow assessment during neurosurgical procedures. J Cereb Blood Flow Metab 2013; 33 (07) 1000-1007
  • 15 Raabe A, Beck J, Gerlach R, Zimmermann M, Seifert V. Near-infrared indocyanine green video angiography: a new method for intraoperative assessment of vascular flow. Neurosurgery 2003; 52 (01) 132-139 , discussion 139
  • 16 Acland RD. Discussion of “The effect of the “patency test” on arterial endothelial surface. Plast Reconstr Surg 1986; 77 (06) 964
  • 17 Petry JJ, French TS, Wortham KA. The effect of the “patency test” on arterial endothelial surface. Plast Reconstr Surg 1986; 77 (06) 960-964
  • 18 Margić K. Early changes in dissected small vessels: experimental study on rat arteries and veins. Plast Reconstr Surg 1985; 75 (03) 375-383
  • 19 Handschel J, Burghardt S, Naujoks C, Kübler NR, Giers G. Parameters predicting complications in flap surgery. Oral Surg Oral Med Oral Pathol Oral Radiol 2013; 115 (05) 589-594
  • 20 Pohlenz P, Klatt J, Schön G, Blessmann M, Li L, Schmelzle R. Microvascular free flaps in head and neck surgery: complications and outcome of 1000 flaps. Int J Oral Maxillofac Surg 2012; 41 (06) 739-743
  • 21 Cooley BC. A Laboratory Manual for Microvascular and Microtubal Surgery. 2nd ed. Reading, PA: Surgical Specialties Corporation; 2009
  • 22 Glover MG, Seaber AV, Urbaniak JR. Intimal tears and their relationship to long-term patency in the rat femoral artery. Microsurgery 1986; 7 (03) 124-127
  • 23 Blackburn CW, Vossoughi SR, Ojo B. , et al. A comparison of the minimal-touch technique and the eversion technique for microvascular anastomosis in a rat model. J Reconstr Microsurg 2017; 33 (02) 97-102
  • 24 Akelina Y, Danilo P. Endogenous adipose tissue as a hemostatic: use in microsurgery. Microsurgery 2008; 28 (03) 192-196
  • 25 Krag C, Holck S. The value of the patency test in microvascular anastomosis: correlation between observed patency and size of intraluminal thrombus: an experimental study in rats. Br J Plast Surg 1981; 34 (01) 64-66