Rofo 1999; 171(Bd.2/1): 65-68
DOI: 10.1055/s-1999-9896
INNOVATION
© Georg Thieme Verlag Stuttgart · New York

Quantifizierung energiereicher Phosphate im gesunden und geschädigten Herzmuskel mittels SLOOP 31P-MR-Spektroskopie

Determination of absolute concentrations of cardiac high-energy phosphates using 31P-MR-spectroscopy and SLOOP in healthy and diseased myocardium.M. Beer1 , W. Landschütz2 , M. Meininger3 , T. Seyfarth1 , M. Viehrig1 , J. Sandstede1 , T. Pabst1 , W. Kenn1 , M. Horn3 , K. Harre3 , M. von Kienlin2 , S. Neubauer3 , D. Hahn1
  • 1Institut für Röntgendiagnostik
  • 2Physikalisches Institut
  • 3Medizinische Klinik
  • der Universität Würzburg
Further Information

Publication History

Publication Date:
31 December 1999 (online)

Zusammenfassung.

Ziel: Erprobung einer quantitativen 31P-MR-spektroskopischen Methode zur Erfassung des Energiestoffwechsels im gesunden und geschädigten Myokard. Methoden: Mittels einer 3D-chemical-shift-imaging-Technik wurden 31P-Spektren auf einem 1,5 T Gerät akquiriert. Unter Berücksichtigung der anatomischen Information von 1H-Bildern erlaubt das SLOOP-Rekonstruktionsverfahren (Spatial Localization with Optimal Pointspread Function) Spektren aus definierten Arealen zu bestimmen. Dabei ist es möglich, das Untersuchungsvolumen an anatomische Strukturen, z. B. den Herzmuskel anzupassen. Die Absolutkonzentrationen für Phosphor-Kreatin (PCr) und Adensosintriphosphat (ATP) wurden unter Bezug auf einen externen Standard bestimmt. Ergebnisse: Die 31P-Spektren zeigten eine geringe Kontamination mit umgebenden Gewebeanteilen. Die an gesunden Probanden bestimmten Absolutwerte wiesen eine geringe Schwankungsbreite auf. Bei dilatativer Kardiomyopathie und koronarer Herzerkrankung zeigten sich erniedrigte PCr- und ATP-Konzentrationen, bei hypertensiver Herzerkrankung unveränderte Konzentrationen im Vergleich zu Gesunden. Schlußfolgerung: Die 31P-MR-Spektroskopie mit SLOOP ermöglicht nichtinvasive, quantitative Aussagen über den kardialen Energiestoffwechsel.

Purpose: A quantitative 31P-MR-spectroscopic technique was used to assess the energy metabolism in healthy and diseased myocardium. Methods: 31P-spectra were acquired on a 1.5 T scanner using a 3D-chemical shift imaging technique. Based on the anatomical information provided by 1H-images, SLOOP (Spatial Localization with Optimal Pointspread Function) allows to obtain spectra from defined compartments. With SLOOP a free voxel shape with adaption to anatomic structures, e.g. the myocardium, is possible. Absolute values for phosphocreatine (PCr) and adenosine triphosphate (ATP) were determined using an external standard. Results: 31P-spectra showed only minimal contamination by surrounding tissue. The standard deviation for the determined values of healthy volunteers was low. Compared to healthy volunteers, reduced PCr and ATP concentrations were seen for dilative cardiomyopathies and coronary artery disease and unchanged concentrations were observed for hypertensive heart disease. Conclusion: 31P-MR-spectroscopy with SLOOP allows a non-invasive, quantitative analysis of cardiac energy metabolism.

Literatur

  • 1 Bottomley P A, Hardy C J, Roemer P B. Phosphate metabolite imaging and concentration measurements in human heart by nuclear magnetic resonance.  Magn Reson Med. 1990;  14 425-434
  • 2 Bottomley P A, Atalar E, Weiss R G. Human cardiac high-energy phosphate metabolite concentrations by 1-D-resolved NMR spectroscopy.  Magn Reson Med. 1996;  35 664-670
  • 3 Neubauer S, Krahe T, Schindler R, Horn M, Hillenbrand H, Entzeroth C, Mader H, Kromer E P, Riegger G AJ, Lackner K, Ertl G. 31P magnetic resonance spectroscopy in dilated cardiomyopathy and coronary artery disease.  Circulation . 1992;  86 1810-1818
  • 4 Krahe T, Schindler R, Neubauer S, Ertl G, Horn M, Lackner K. 31P-Kardio-MR-Spektroskopie bei Myokardinsuffizienz.  Fortschr Röntgenstr. 1993;  159 64-70
  • 5 Yabe T, Mitsunami K, Inubushi T, Kinoshita M. Quantitative measurements of cardiac phosphorus metabolites in coronary artery disease by 31P magnetic resonance spectroscopy.  Circulation. 1995;  92 15-23
  • 6 Von Kienlin M, Mejia R. Spectral localization with optimal pointspread function.  J Magn Reson. 1991;  94 268-287
  • 7 Löffler R, Sauter R, Kolem H, Haase A, von Kienlin M. Localized spectroscopy from anatomically matched compartments: improved sensitivity and localization for cardiac 31P-MRS in humans.  J Magn Reson. 1998;  134 287-299
  • 8 Meininger M, Landschütz W, Beer M, Seyfarth T, Horn M, Pabst T, Haase A, Hahn D, Neubauer S, von Kienlin M. Concentrations of human cardiac phosphorus metabolites determined by SLOOP 31P NMR spectroscopy.  Magn Reson Med. 1999;  41 659-663
  • 9 Beer M, Pabst T, Seyfarth T, Viehrig M, Sandstede J, Kenn W, Horn M, Bertsch G, Landschütz W, Meininger M, v. Kienlin M, Neubauer S, Hahn D. Bestimmung von NOE-Korrekturfaktoren für die 31P-Spektroskopie des Herzens.  Fortschr Röntgenstr. 1998;  168 75
  • 10 Bottomley P A, Ouwerkerk R. Optimum flip angles for exciting NMR with uncertain T1 values.  Magn Reson Med. 1994;  32 137-141
  • 11 Vanhamme L, van den Boogart A, van Huffel S. Improved method for accurate and efficient quantification of MRS data with use of prior knowledge.  J Magn Reson. 1997;  129 35-43

Dr. med. Meinrad Beer

Institut für Röntgendiagnostik der Universität Würzburg

Josef-Schneider-Straße 2 D-97070 Würzburg

Phone: 0931/2013472

Fax: 0931/2013521

Email: meinrad.beer@mail.uni-wuerzburg.de

    >