ABSTRACT

The purpose of this study was to determine whether there is a relationship between pulmonary function measured during wakefulness and sleep apnea. We prospectively studied 1296 patients, who were free of any lung disease, referred to our sleep clinic for evaluation of possible sleep apnea. All patients had in-hospital nocturnal polysomnography and pulmonary function measurements, which included flow-volume curve, body plethysmography, and single-breath diffusing capacity for carbon monoxide. The results were analyzed by comparing pulmonary function data between four groups of patients, grouped according to apnea severity as reflected by their apnea/hypopnea index: nonapneics (apnea-hypopnea index ≤ 10), mild apnea (10 < apnea-hypopnea index ≤ 30), moderate apnea (30 < apnea-hypopnea index ≤ 50), and severe apnea (apnea-hypopnea index > 50). Analysis of covariance demonstrated no difference in any of the pulmonary function parameters between the four groups, after adjusting for age, body mass index, or weight as the covariate. We conclude that in nonsmoking patients without lung disease, sleep apnea is unrelated to pulmonary function measured during wakefulness.

REFERENCES

  • 1 Fogel R B, White D P. Obstructive sleep apnea.  Adv Intern Med . 2000;  45 351-389
  • 2 Rubinstein I, Zamel N, Du Barry L. et al . Airflow limitation in morbidly obese non-smoking men.  Ann Intern Med . 1990;  112 828-832
  • 3 Sanders M H, Martin R J, Pennock B E. et al . The detection of sleep apnea in the awake patient: the “saw-tooth” sign.  JAMA . 1981;  245 2414-2418
  • 4 Haponik E F, Bleecker E R, Allen R P. et al . Abnormal inspiratory flow-volume curves in patients with sleep-disordered breathing.  Am Rev Respir Dis . 1981;  124 571-574
  • 5 Hoffstein V, Wright S, Zamel N. Flow-volume curves in snoring patients with and without obstructive sleep apnea.  Am Rev Respir Dis . 1989;  139 957-960
  • 6 Katz I, Zamel N, Rebuck A S. et al . An evaluation of flow-volume curves as a screening test for obstructive sleep apnea.  Chest . 1990;  98 337-339
  • 7 Sériès F, Marc I. Accuracy of breath-by-breath analysis of flow-volume loop in identifying sleep-induced flow-limited breathing cycles in sleep apnoea-hypopnoea syndrome.  Clin Sci . 1995;  88 707-712
  • 8 Stanescu D, Kostianev S, Sanna A. et al . Expiratory flow limitation during sleep in heavy snorers and obstructive sleep apnea patients.  Eur Respir J . 1996;  9 2116-2121
  • 9 Liistro G, Veriter C, Dury M. et al . Expiratory flow limitation in awake sleep-disordered breathing subjects.  Eur Respir J . 1999;  14 185-190
  • 10 Campbell A H, Guy P A, Rochford P D. et al . Flow-volume curve changes in patients with obstructive sleep apnoea and brief upper airway dysfunction.  Respirology . 2000;  5 11-18
  • 11 Hoffstein V, Brown I, Taylor R, McLean P, Zamel N. Flow ratios at mid-vital capacity in normal men and women.  Chest . 1986;  90 857-860
  • 12 Hoffstein V. Relationship between smoking and sleep apnea in clinic population.  Sleep . 2002;  25 519-524
  • 13 American Thoracic Society. Standardization of spirometry: 1994 update.  Am J Respir Crit Care Med . 1995;  152 1107-1136.
  • 14 American Thoracic Society. Lung function testing: selection of reference values and interpretive strategies.  Am Rev Respir Dis . 1991;  144 1202-1218
  • 15 Cody R P, Smith J K. Applied Statistics and the SAS Programming Language, 4th ed. Upper Saddle River, NJ: Prentice-Hall; 1997 . 
  • 16 Zerah-Lancner F, Lofaso F, Coste A. et al . Pulmonary function in obese snorers with or without sleep apnea syndrome.  Am J Respir Crit Care Med . 1997;  156 522-527
  • 17 Gold A R, Schwartz A R, Wise R A. et al . Pulmonary function and respiratory chemosensitivity in moderately obese patients with sleep apnea.  Chest . 1993;  103 1325-1329
  • 18 Stauffer J L, White D P, Zwillich C W. Pulmonary function in obstructive sleep apnea: relationships to pharyngeal resistance and cross-sectional area.  Chest . 1990;  97 302-307
  • 19 de Miguel J, Cabello J, Sánchez-Alarcos J MF, Álvarez-Sala R, Espinós D, Álvarez-Sala J L. Long-term effects of treatment with nasal continuous positive airway pressure on lung function in patients with overlap syndrome.  Sleep Breath . 2002;  6 3-10
  • 20 Collard P, Wilputte J Y, Aubert G. et al . The single-breath diffusing capacity for carbon monoxide in obstructive sleep apnea and obesity.  Chest . 1996;  110 1189-1193
  • 21 Zamarrón C, Gude F, Alvarez J M. et al . Airway disorders and pulmonary function in snorers; a population-based study.  Respir Med . 2000;  94 835-840
  • 22 Larsson L G, Lundbäck B, Jönsson E. et al . Are symptoms of obstructive sleep apnea syndrome related to bronchitic symptoms or lung function impairment?.  <~>Report from the obstructive lung disease in Northern Sweden study. Respir Med . 1998;  92 283-288
  • 23 Chaouat A, Weitzenblum E, Krieger J. et al . Prognostic value of lung function and pulmonary hemodynamics in OSA patients treated with CPAP.  Eur Respir J . 1999;  13 1091-1096
  • 24 Zerah-Lancner F, Lofaso F, D'Ortho M P. et al . Predictive value of pulmonary function parameters for sleep apnea syndrome.  Am J Respir Crit Care Med . 2000;  162 2208-2212
    >