J Knee Surg 2024; 37(01): 020-025
DOI: 10.1055/a-2176-4767
Special Focus Section

Accuracy of Conventional Instrumentation is Dependent on Alignment Philosophy Using the Identical Surgical Technique in Total Knee Arthroplasty

Amir Koutp
1   Department of Orthopaedics and Trauma, Medical University of Graz, Graz, Austria
,
Clemens Clar
1   Department of Orthopaedics and Trauma, Medical University of Graz, Graz, Austria
,
Lukas Leitner
1   Department of Orthopaedics and Trauma, Medical University of Graz, Graz, Austria
,
Stefan Fischerauer
1   Department of Orthopaedics and Trauma, Medical University of Graz, Graz, Austria
,
Patrick Reinbacher
1   Department of Orthopaedics and Trauma, Medical University of Graz, Graz, Austria
,
Andreas Leithner
1   Department of Orthopaedics and Trauma, Medical University of Graz, Graz, Austria
,
2   Department of Orthopaedics and Traumatology, AUVA UKH Steiermark, Graz, Austria
,
Patrick Sadoghi
1   Department of Orthopaedics and Trauma, Medical University of Graz, Graz, Austria
› Author Affiliations
Funding P.S. and A.L. report institutional educational grants by Johnson & Johnson, Alphamed, Medacta, and ImplanTec.

Abstract

The objective of this prospective study was to assess the precision of restoring the anatomical tibial obliquity, as measured by the medial proximal tibial angle (MPTA) on conventional X-rays, in relation to the surgical technique employed. Specifically, the study aimed to compare the accuracy of tibial obliquity restoration between kinematic alignment (KA) and conventional mechanical alignment (MA) in total knee arthroplasty (TKA). Two-hundred-and-sixty patients underwent either mechanically aligned TKA (n = 139) or kinematically aligned TKA (n = 121) using conventional instrumentation (CI). Pre- and postoperative X-rays were measured twice by two observers, with a 2-week interval. Inter- and intraclass correlations were calculated, and postoperative tibial obliquity was compared to the preoperative anatomy. In the group of 139 patients with mechanically aligned TKA, no cases with an MPTA deviation greater than 1 degree from 90 degrees were observed. Sixteen percent of the cases (n = 22) had a deviation of 0 to 1 degree. The remaining 84% of the cases (n = 117) had their MPTA of 90 degrees achieved. In the group of 121 patients with kinematically aligned TKA, no cases had a deviation greater than 1 degree compared with the preoperative MPTA. Thirty-one percent of the cases (n = 37) had a deviation of 0 to 1 degree with respect to preoperative MPTA. The remaining 69% of the cases (n = 84) had their tibial obliquity restored. Mechanically aligned TKA revealed statistically significant smaller deviations of accuracy compared to kinematically aligned TKA (p = 0.005). The inter- and intraclass correlations indicated substantial agreement of all measurements (intraclass correlation coefficient [ICC] < 0.90). Both mechanically aligned and kinematically aligned TKA demonstrated satisfactory outcomes in terms of restoring tibial obliquity or a neutral MPTA of 90 degrees using CI. However, MA showed superior results regarding precision compared to KA. When starting with kinematical alignment using CI, the surgeons should be aware that the learning curve according to accuracy differs to MA. It was a Prospective Level II study.

Authors' Contributions

All authors have made substantial contributions by acquisition, analysis, and interpretation of data as well as drafting and revising the article. Results were discussed and all authors approved the submission of the manuscript.




Publication History

Received: 03 August 2023

Accepted: 14 September 2023

Accepted Manuscript online:
15 September 2023

Article published online:
30 October 2023

© 2023. Thieme. All rights reserved.

Thieme Medical Publishers, Inc.
333 Seventh Avenue, 18th Floor, New York, NY 10001, USA

 
  • References

  • 1 Lotke PA, Ecker ML. Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg Am 1977; 59 (01) 77-79
  • 2 Insall JN, Binazzi R, Soudry M, Mestriner LA. Total knee arthroplasty. Clin Orthop Relat Res 1985; (192) 13-22
  • 3 Roussot MA, Vles GF, Oussedik S. Clinical outcomes of kinematic alignment versus mechanical alignment in total knee arthroplasty: a systematic review. EFORT Open Rev 2020; 5 (08) 486-497
  • 4 Hirschmann MT, Moser LB, Amsler F, Behrend H, Leclerq V, Hess S. Functional knee phenotypes: a novel classification for phenotyping the coronal lower limb alignment based on the native alignment in young non-osteoarthritic patients. Knee Surg Sports Traumatol Arthrosc 2019; 27 (05) 1394-1402
  • 5 Smolle MA, Koutp A, Clar C, Leitner L, Leithner A, Sadoghi P. Restoring tibial obliquity for kinematic alignment in total knee arthroplasty: conventional versus patient-specific instrumentation. Arch Orthop Trauma Surg 2023; 143 (09) 5867-5872
  • 6 Vendittoli P-A, Martinov S, Blakeney WG. Restricted kinematic alignment, the fundamentals, and clinical applications. Front Surg 2021; 8: 697020
  • 7 Bellemans J, Colyn W, Vandenneucker H, Victor J. The Chitranjan Ranawat award: is neutral mechanical alignment normal for all patients? The concept of constitutional varus. Clin Orthop Relat Res 2012; 470 (01) 45-53
  • 8 Benjamin J. Component alignment in total knee arthroplasty. Instr Course Lect 2006; 55: 405-412
  • 9 Park J-K, Seon J-K, Cho K-J, Lee N-H, Song E-K. Is immediate postoperative mechanical axis associated with the revision rate of primary total knee arthroplasty? A 10-year follow-up study. Clin Orthop Surg 2018; 10 (02) 167-173
  • 10 Abdel MP, Ollivier M, Parratte S, Trousdale RT, Berry DJ, Pagnano MW. Effect of postoperative mechanical axis alignment on survival and functional outcomes of modern total knee arthroplasties with cement: a concise follow-up at 20 years. J Bone Joint Surg Am 2018; 100 (06) 472-478
  • 11 Almaawi AM, Hutt JRB, Masse V, Lavigne M, Vendittoli P-A. The impact of mechanical and restricted kinematic alignment on knee anatomy in total knee arthroplasty. J Arthroplasty 2017; 32 (07) 2133-2140
  • 12 Hirschmann MT, Becker R, Tandogan R, Vendittoli P-A, Howell S. Alignment in TKA: what has been clear is not anymore!. Knee Surg Sports Traumatol Arthrosc 2019; 27 (07) 2037-2039
  • 13 Howell SM, Howell SJ, Kuznik KT, Cohen J, Hull ML. Does a kinematically aligned total knee arthroplasty restore function without failure regardless of alignment category?. Clin Orthop Relat Res 2013; 471 (03) 1000-1007
  • 14 Kastner N, Gruber G, Aigner BA. et al. Sex-related outcome differences after implantation of low-contact-stress mobile-bearing total knee arthroplasty. Int Orthop 2012; 36 (07) 1393-1397
  • 15 Kastner N, Sternbauer S, Friesenbichler J. et al. Impact of the tibial slope on range of motion after low-contact-stress, mobile-bearing, total knee arthroplasty. Int Orthop 2014; 38 (02) 291-295
  • 16 Howell SM. Calipered kinematically aligned total knee arthroplasty: an accurate technique that improves patient outcomes and implant survival. Orthopedics 2019; 42 (03) 126-135
  • 17 Dossett HG, Estrada NA, Swartz GJ, LeFevre GW, Kwasman BG. A randomised controlled trial of kinematically and mechanically aligned total knee replacements: two-year clinical results. Bone Joint J 2014; 96-B (07) 907-913
  • 18 Waterson HB, Clement ND, Eyres KS, Mandalia VI, Toms AD. The early outcome of kinematic versus mechanical alignment in total knee arthroplasty: a prospective randomised control trial. Bone Joint J 2016; 98-B (10) 1360-1368
  • 19 Calliess T, Bauer K, Stukenborg-Colsman C, Windhagen H, Budde S, Ettinger M. PSI kinematic versus non-PSI mechanical alignment in total knee arthroplasty: a prospective, randomized study. Knee Surg Sports Traumatol Arthrosc 2017; 25 (06) 1743-1748