Thorac Cardiovasc Surg 2025; 73(04): 264-271
DOI: 10.1055/a-2198-1235
Original Cardiovascular

Acquired Thrombocytopenia in Contemporary Transcatheter Aortic Valve Prosthesis

1   Department of Cardiac Surgery, Heart Centre Dresden, University Hospital of the University of Technology Dresden, Dresden, Sachsen, Germany
,
Ali Taghizadeh-Waghefi
1   Department of Cardiac Surgery, Heart Centre Dresden, University Hospital of the University of Technology Dresden, Dresden, Sachsen, Germany
,
Abdel-Hannan Diab
1   Department of Cardiac Surgery, Heart Centre Dresden, University Hospital of the University of Technology Dresden, Dresden, Sachsen, Germany
,
Linda Breuer
1   Department of Cardiac Surgery, Heart Centre Dresden, University Hospital of the University of Technology Dresden, Dresden, Sachsen, Germany
,
Sebastian Arzt
1   Department of Cardiac Surgery, Heart Centre Dresden, University Hospital of the University of Technology Dresden, Dresden, Sachsen, Germany
,
Klaus Ehrhard Matschke
1   Department of Cardiac Surgery, Heart Centre Dresden, University Hospital of the University of Technology Dresden, Dresden, Sachsen, Germany
,
Konstantin Alexiou
1   Department of Cardiac Surgery, Heart Centre Dresden, University Hospital of the University of Technology Dresden, Dresden, Sachsen, Germany
› Author Affiliations
Preview

Abstract

Background Postprocedural thrombocytopenia is a known phenomenon following transcatheter aortic valve implantation (TAVI). The aim of this study is to evaluate whether postinterventional platelet kinetics differ when comparing the current generation of balloon-expandable valve (BEV) and self-expanding valve (SEV) prostheses.

Methods We performed a retrospective analysis of patients undergoing TAVI at our facility between 2017 and 2019. Patients were stratified according to the type of prosthesis used: BEV or SEV. Hematocrit-corrected platelet counts were calculated to account for dilution. Nadir platelet counts (lowest recorded platelet count), drop platelet counts (DPC; highest relative platelet drop from baseline), and severity of thrombocytopenia during the discourse and at discharge were assessed.

Results Of the 277 included patients, 212 received SEV and 65 BEV. BEV patients were younger (81.8 ± 4.4 years vs 79.7 ± 6.8 years, p = 0.03). Further demographic characteristics were similar between groups. Implanted SEV were larger (p < 0.001) and had shorter procedural times (p < 0.01). There were no significant differences in postprocedural discourse. Postinterventional platelet drop was more pronounced in BEV patients in several evaluated metrics: mean DPC (24.3 ± 10.9% vs 18.8 ± 14.8%, p < 0.01), patients with DPC > 30% (n = 19, 29.2%, vs n = 33, 15.6%, p = 0.02), and also when comparing platelet kinetics.

Conclusion Despite improvements in outcome, the current generation of balloon-expandable TAVI prostheses carries a predisposition for postprocedural thrombocytopenia even when the effects of dilution are accounted for.

Data Availability Statement

The data underlying this article will be shared on reasonable request to the corresponding author.


Supplementary Material



Publication History

Received: 05 June 2023

Accepted: 14 October 2023

Accepted Manuscript online:
25 October 2023

Article published online:
18 December 2023

© 2023. Thieme. All rights reserved.

Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany