Abstract
Achieving anatomic reduction, securing fixation, and ensuring adequate compression
are crucial steps in the internal fixation process for traumatic osteochondral defects.
A variety of fixation methodologies have been in use, e.g., metal pins, bioabsorbable
screws, and glue tissue adhesives, each of them yielding different outcomes. This
study presents the outcomes of utilising the concept of suture bridge fixation for
traumatic femoral osteochondral injury in a 34-year-old patient. Following a three-year
follow-up, the patient demonstrated a return to normal activities with complete and
pain-free knee mobility. In conclusion, it can be stated that suture bridges offer
an alternative approach for the fixation of osteochondral fragments in the knee attributable
to traumatic injuries.
Zusammenfassung
Bei der internen Fixierung traumatischer osteochondraler Defekte ist es von entscheidender
Bedeutung, eine anatomische Reposition zu erreichen, die Fixierung zu sichern und
eine angemessene Kompression zu gewährleisten. Es wurden verschiedene Fixierungsmethoden
wie Metallstifte, bioresorbierbare Schrauben und Gewebekleber eingesetzt, die jeweils
zu unterschiedlichen Ergebnissen führten. In dieser Studie werden die Ergebnisse der
Anwendung des Konzepts der Suture-Bridge-Fixierung bei traumatischen femoralen osteochondralen
Verletzungen bei einem 34-jährigen Patienten vorgestellt. Nach einer Nachbeobachtungszeit
von 3 Jahren konnte der Patient seine normalen Aktivitäten wieder aufnehmen und sein
Knie vollständig und schmerzfrei bewegen. Daher bietet die Suture-Bridge-Technik einen
alternativen Ansatz für die Fixierung von osteochondralen Fragmenten im Knie, die
auf traumatische Verletzungen zurückzuführen sind.
Keywords osteochondral fracture - chondral fracture - suture bridge
Schlüsselwörter osteochondrale Fraktur - chondrale Fraktur - Nahtbrücke