Vet Comp Orthop Traumatol
DOI: 10.1055/a-2577-1520
Clinical Communication

Temporary Transarticular Immobilization of the Stifle Joint Using a Locking Plate

Ida Forzisi
1   Clinica Veterinaria Vezzoni, Surgical Department, Cremona, Italy
,
Alessio Raschi
2   Centro Veterinario Orthopedica, Surgical Department, Firenze, Italy
,
1   Clinica Veterinaria Vezzoni, Surgical Department, Cremona, Italy
,
Luca Vezzoni
1   Clinica Veterinaria Vezzoni, Surgical Department, Cremona, Italy
› Author Affiliations
Preview

Abstract

Objective

Our study aims to describe the surgical technique for temporary transarticular immobilization of the stifle joint using a locking plate and evaluate complications and outcomes.

Methods

The medical records of dogs and cats that underwent transarticular immobilization of the stifle joint using a locking plate in two institutions from August 2018 to January 2024 were retrospectively evaluated.

After managing the primary injury, a locking plate was contoured to fit the medial surface of the distal femur and proximal tibia, limiting the implant to the distal third of the femur and proximal third of the tibia, with immobilization at a 135 to 145-degree angle.

Results

Temporary transarticular immobilization of the stifle joint was performed in 16 stifle joints in 14 patients, with two dogs undergoing bilateral surgery. The transarticular implants were removed at a mean time of 55,86 ± 18,05 days postoperatively (median: 58, range: 27–96 days). No intraoperative complications were recorded. One major complication was recorded in a Galgo Espanol with a patellar fracture and patellar ligament lesion in which plate breakage was recorded 19 days after surgery, requiring early plate removal and application of an orthosis for 3 weeks. Four minor complications were recorded.

Clinical significance

Preliminary results suggest that a transarticular locking plate is effective for temporary stifle immobilization, with a low morbidity and complication rate. Dedicated implants should be developed to decrease the risk of plate failure.

Authors' Contribution

L.V. and I.F. contributed to the conception of the study. L.V., I.F., A.R., and A.V. contributed to the study design, acquisition of data, data analysis, and interpretation. All authors drafted, revised, and approved the submitted manuscript.


Supplementary Material



Publication History

Received: 30 June 2024

Accepted: 07 April 2025

Article published online:
30 April 2025

© 2025. Thieme. All rights reserved.

Georg Thieme Verlag KG
Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany