Ultraschall Med 2011; 32(5): 492-496
DOI: 10.1055/s-0029-1246002
Originalarbeiten/Original Article

© Georg Thieme Verlag KG Stuttgart · New York

Microwave Ablation of Liver Metastases Guided by Contrast-Enhanced Ultrasound: Experience with 125 Metastases in 39 Patients

CEUS-gestützte Mikrowellenablation von Lebermetastasen: Erfahrungen bei 39 Patienten mit 125 MetastasenT. Lorentzen1 , B. O. Skjoldbye1 , C. P. Nolsoe1
  • 1Department of Gastric Surgery, Herlev Hospital, University of Copenhagen
Further Information

Publication History

received: 24.6.2010

accepted: 15.12.2010

Publication Date:
21 January 2011 (online)

Zusammenfassung

Ziel: Ziel der Studie war die Beurteilung der Effektivität der B-Mode-Ultraschall(US)- und kontrastverstärkten US(CEUS)- gestützten Mikrowellenablation (MWA) von Lebermetastasen. Patienten und Methoden: 39 Patienten (17 weiblich, 22 männlich) mit insgesamt 125 Lebermetastasen wurden mit perkutaner oder intraoperativer CEUS-gestützter MWA behandelt. Die Primarien waren kolorektale Karzinome (n = 31), Mammakarzinome (n = 6), karzinoide Tumoren (n = 1) und gastrointestinale Stromatumoren (GIST) (n = 1). Die mediane Anzahl der abladierten Metastasen in den 45 Behandlungssitzungen war 2 (Spannweite 1 – 11). Die mediane Größe (maximaler Durchmesser) der 125 Metastasen war 1,5 cm (Spannweite 0,6 – 4,0 cm). 19 (15 %) der 125 Metastasen waren größer als 2 cm. Metastasen, die kleiner als 2 cm waren, wurden mit einer einzelnen Nadel behandelt, Metastasen, die größer als 2 cm waren, wurden mit 2 oder 3 parallelen Nadeln behandelt. Ergebnisse: Von den 45 MWA-Sitzungen wurden 30 perkutan durchgeführt, 3 im Rahmen einer Laparotomie und 12 im Rahmen einer Laparotomie in Kombination mit einer Leberresektion. Die 39 Patienten wurden für mindestens 4 Monate mit einer mittleren Dauer von 11 Monaten (Spannweite 4 – 20 Monate) nachverfolgt. Die technische Erfolgsrate war 100 %. Die klinische Effektivität war 100 % mit kompletter Abdeckung der Metastasen durch die avaskuläre Koagulationszone entsprechend der Beurteilung mittels direkt postablativem CEUS. Eine lokale Tumorprogression (lokales Rezidiv) gab es bei 12 (9,6 %) der 125 behandelten Metastasen und betraf 10 (26 %) der 39 Patienten. Eine schwere Komplikation trat in Form eines Leberabszesses auf, der sich gut mittels perkutaner Drainage behandeln ließ. 4 leichte Komplikationen wurden beobachtet: 3 Fälle mit lokalem Schmerz an der Punktionsstelle und ein Fall mit Aszites. CEUS war wertvoll in allen Phasen der Ablation einschließlich des präablativen Stagings, Planung des Prozederes, Platzierung der Mikrowellennadeln in der Raumforderung, unmittelbare postablative Kontrolle der Koagulationsgröße und schließlich im Langzeit-Follow-up. Schlussfolgerung: CEUS-gestützte MWA von Lebermetastasen ist eine sichere und effektive Ablationstechnik mit einigen Vorteilen gegenüber anderen Ablationsmodalitäten.

Abstract

Purpose: The aim of our study was to evaluate the efficacy of microwave (MW) ablation of liver metastases guided by B-mode ultrasound (US) and contrast-enhanced US (CEUS). Materials and Methods: 39 patients (17 women and 22 men) with a total of 125 liver metastases were treated with percutaneous or intraoperative CEUS-guided MW ablation. The primary tumor was colorectal cancer (n = 31), breast cancer (n = 6), carcinoid tumor (n = 1), and gastrointestinal stromal tumor (GIST) (n = 1). The median number of metastases ablated in the 45 treatment sessions was 2 (range 1 – 11). The median size (maximum diameter) of the 125 metastases was 1.5 cm (range, 0.6 – 4.0 cm). Nineteen (15 %) of the 125 metastases were bigger than 2 cm. Metastases smaller than 2 cm were treated with a single needle, metastases bigger than 2 cm were treated with 2 or 3 parallel needles. Results: The 45 MW ablation sessions were performed percutaneously (n = 30), during laparotomy (n = 3), or during laparotomy combined with liver resection (n = 12). The 39 patients were followed up for at least 4 months with a median duration of 11 months (range, 4 – 20 months). The technical success rate was 100 %. The clinical effectiveness was 100 % with complete coverage of the metastasis by the avascular coagulation zone evaluated on immediate post-ablation CEUS. Local tumor progression (local recurrence) was seen in 12 (9.6 %) of the 125 treated metastases, and affected 10 (26 %) of the 39 patients. One major complication was observed in the form of a liver abscess that easily resolved after percutaneous drainage. Four minor complications were observed: Three cases of pain located at the puncture site and one case of ascites. CEUS was valuable in all phases of ablation including pre-ablation staging and procedure planning, placement of MW needles in the tumor, immediate post-ablation control of coagulation size, and finally in the long term follow-up regime. Conclusion: CEUS-guided MW ablation of liver metastases is an efficient and safe ablation technique with several advantages compared to other ablation modalities.

References

  • 1 Steele Jr G, Ravikumar T S. Resection of hepatic metastases from colorectal cancer: Biological perspectives.  Ann Surg. 1989;  210 127-138
  • 2 Gillams A R, Lees W R. Five-year survival in 309 patients with colorectal liver metastases treated with radiofrequency ablation.  Eur Radiol. 2009;  19 1206-1213
  • 3 Martin R C, Scoggins C R, McMasters K M. Safety and efficacy of microwave ablation of hepatic tumors: a prospective review of a 5-year experience.  Ann Surg Oncol. 2010;  17 171-178
  • 4 Simon C J, Dupuy D E, Mayo-Smith W W. Microwave ablation: principles and applications.  Radiographics. 2005;  25 S69-S83
  • 5 Nolsøe C P, Lorentzen T, Skjoldbye B O et al. The basics of interventional ultrasound.  Ultraschall in Med. 2007;  28 248-263
  • 6 Claudon M, Cosgrove D, Albrecht T et al. Guidelines and good clinical practice recommendations for contrast enhanced ultrasound (CEUS) – update 2008.  Ultraschall in Med. 2008;  29 28-44
  • 7 Goldberg S N, Grassi C J, Cardella J F et al. Image-guided Tumor Ablation: Standardization of Terminology and Reporting Criteria.  J Vasc Interv Radiol. 2009;  20 S377-S390
  • 8 Bhardwaj N, Strickland A D, Ahmad F et al. A comparative histological evaluation of the ablations produced by microwave, cryotherapy and radiofrequency in the liver.  Pathology. 2009;  41 168-172
  • 9 Awad M M, Devgan L, Kamel I R et al. Microwave ablation in a hepatic porcine model: correlation of CT and histopathologic findings.  HPB. 2007;  9 357-362
  • 10 Meloni M F, Andreano A, Laeseke P F et al. Breast cancer liver metastases: US-guided percutaneous radiofrequency ablation – intermediate and long-term survival rates.  Radiology. 2009;  253 861-869
  • 11 Liang P, Wang Y, Yu X et al. Malignant liver tumors: treatment with percutaneous microwave ablation –complications among cohort of 1136 patients.  Radiology. 2009;  251 933-940
  • 12 Yu N C, Lu D S, Raman S S et al. Hepatocellular carcinoma: microwave ablation with multiple straight and loop antenna clusters - pilot comparison with pathologic findings.  Radiology. 2006;  239 269-275
  • 13 Hompes R et al. Results of single-probe microwave ablation of metastatic liver cancer.  Eur J Surg Oncol. 2010;  in press DOI: 10.1016 /j.ejso.2010.05.013
  • 14 Brace C L, Diaz T A, Hinshaw J L et al. Tissue Contraction Caused by Radiofrequency and Microwave Ablation: A Laboratory Study in Liver and Lung.  J Vasc Interv Radiol. 2010;  , in press
  • 15 Bhardwaj N, Strickland A D, Ahmad F et al. Microwave ablation for unresectable hepatic tumours: Clinical results using a novel microwave probe and generator.  Eur J Surg Oncol. 2010;  36 264-268
  • 16 Carrafiello G, Mangini M, Fontana F et al. Single-antenna microwave ablation under contrast-enhanced ultrasound guidance for treatment of small renal cell carcinoma: preliminary experience.  Cardiovasc Intervent Radiol. 2010;  33 367-374
  • 17 Meloni F, Andreano A, Lava M et al. Contrast-enhanced ultrasound: role in immediate post-procedural evaluation of liver tumors thermal ablation effectiveness.  WICO. 2010;  , oral presentation and abstract
  • 18 Ricci P, Cantisani V, Drudi F et al. Is contrast-enhanced US alternative to spiral CT in the assessment of treatment outcome of radiofrequency ablation in hepatocellular carcinoma?.  Ultraschall in Med. 2009;  30 252-258

Dr. Torben Lorentzen

Department of Gastric Surgery, Herlev Hospital, University of Copenhagen

Herlev Ringvej 75

2720 Herlev

Denmark

Phone:  ++ 45/23 22 66 53

Fax:  ++ 45/39 64 13 33

Email: tlo@dadlnet.dk

    >