CC BY-NC-ND 4.0 · J Neurol Surg Rep 2017; 78(04): e119-e122
DOI: 10.1055/s-0037-1607425
Case Report
Georg Thieme Verlag KG Stuttgart · New York

Low-Intensity Pulsed Ultrasound and Halo Immobilization Is an Effective Treatment for Nonunion Following Traumatic Spondylolisthesis of the Axis

Kohtaroh Oda
1   Department of Orthopaedic Surgery, University of Yamanashi, Yamanashi, Japan
,
Tetsuro Ohba
1   Department of Orthopaedic Surgery, University of Yamanashi, Yamanashi, Japan
,
Shigeto Ebata
1   Department of Orthopaedic Surgery, University of Yamanashi, Yamanashi, Japan
,
Hirotaka Haro
1   Department of Orthopaedic Surgery, University of Yamanashi, Yamanashi, Japan
› Author Affiliations
Further Information

Publication History

20 April 2017

20 September 2017

Publication Date:
03 November 2017 (online)

Abstract

This case report describes a unique case involving traumatic spondylolisthesis of the axis that resulted in nonunion, angulation, and displacement after conservative treatment with a cervical collar, but which was successfully achieved union with halo immobilization and low-intensity pulsed ultrasound (LIPUS). Halo immobilization of a traumatic spondylolisthesis in a 20-year-old patient, that previously failed to improve after wearing a cervical collar for 3 months, was immediately followed by treatment with a LIPUS device (SAFHS 4000J; Teijin Pharma, Tokyo, Japan) 20 minutes once daily to the right and left fracture sites which were located using fluoroscopic guidance. Radiographs and computed tomography showed conclusive evidence of bone union after 10 weeks of treatment with halo immobilization. No adverse events were observed. To the best of our knowledge, this is the first report describing that the combination of halo immobilization and LIPUS therapy might be a safe, effective, and feasible method by which to treat cervical spine fractures.

 
  • References

  • 1 Levine AM, Edwards CC. The management of traumatic spondylolisthesis of the axis. J Bone Joint Surg Am 1985; 67 (02) 217-226
  • 2 Ferro FP, Borgo GD, Letaif OB, Cristante AF, Marcon RM, Lutaka AS. Traumatic spondylolisthesis of the axis: epidemiology, management and outcome. Acta Ortop Bras 2012; 20 (02) 84-87
  • 3 Müller EJ, Wick M, Muhr G. Traumatic spondylolisthesis of the axis: treatment rationale based on the stability of the different fracture types. Eur Spine J 2000; 9 (02) 123-128
  • 4 Li XF, Dai LY, Lu H, Chen XD. A systematic review of the management of hangman's fractures. Eur Spine J 2006; 15 (03) 257-269
  • 5 Buchholz AL, Morgan SL, Robinson LC, Frankel BM. Minimally invasive percutaneous screw fixation of traumatic spondylolisthesis of the axis. J Neurosurg Spine 2015; 22 (05) 459-465
  • 6 Singh PK, Garg K, Sawarkar D. , et al. Computed tomography-guided C2 pedicle screw placement for treatment of unstable hangman fractures. Spine 2014; 39 (18) E1058-E1065
  • 7 Gebauer D, Mayr E, Orthner E, Ryaby JP. Low-intensity pulsed ultrasound: effects on nonunions. Ultrasound Med Biol 2005; 31 (10) 1391-1402
  • 8 Romano CL, Romano D, Logoluso N. Low-intensity pulsed ultrasound for the treatment of bone delayed union or nonunion: a review. Ultrasound Med Biol 2009; 35 (04) 529-536
  • 9 Heckman JD, Sarasohn-Kahn J. The economics of treating tibia fractures. The cost of delayed unions. Bull Hosp Jt Dis 1997; 56 (01) 63-72
  • 10 Einhorn TA. Enhancement of fracture-healing. J Bone Joint Surg Am 1995; 77 (06) 940-956
  • 11 Hur H, Lee JK, Jang JW, Kim TS, Kim SH. Is it feasible to treat unstable hangman's fracture via the primary standard anterior retropharyngeal approach?. Eur Spine J 2014; 23 (08) 1641-1647
  • 12 Yukawa Y, Kato F, Ito K. , et al. Placement and complications of cervical pedicle screws in 144 cervical trauma patients using pedicle axis view techniques by fluoroscope. Eur Spine J 2009; 18 (09) 1293-1299
  • 13 Watanabe Y, Matsushita T, Bhandari M, Zdero R, Schemitsch EH. Ultrasound for fracture healing: current evidence. J Orthop Trauma 2010; 24 (Suppl. 01) S56-S61
  • 14 Cook SD, Salkeld SL, , Mse, Patron LP, Ryaby JP, Whitecloud TS. Low-intensity pulsed ultrasound improves spinal fusion. Spine J 2001; 1 (04) 246-254
  • 15 Hui CF, Chan CW, Yeung HY. , et al. Low-intensity pulsed ultrasound enhances posterior spinal fusion implanted with mesenchymal stem cells-calcium phosphate composite without bone grafting. Spine 2011; 36 (13) 1010-1016