Thromb Haemost 1991; 65(03): 320-322
DOI: 10.1055/s-0038-1648143
Scientific and Standardization Committee Communications
Schattauer GmbH Stuttgart

Guidelines for Testing and Revised Criteria for Lupus Anticoagulants

SSC Subcommittee for the Standardization of Lupus Anticoagulants
Thomas Exner
1   The Haematology Dept., Westmead Hospital, Sydney, N.S.W., Australia
,
Douglas A Triplett
2   The Indiana University School of Medicine, Ball Memorial Hospital, Muncie, IN., USA
,
David Taberner
3   The Withington Hospital, Manchester, UK
,
Samuel J Machin
4   The Middlesex Hospital, London, UK
› Author Affiliations
Further Information

Publication History

Publication Date:
02 July 2018 (online)

 
  • REFERENCES

  • 1 Lechner K. Lupus anticoagulants and thrombosis. In: Thrombosis and Haemostasis 1987 Verstraete M, Vermylen J, Lijnen HR, Arnout J. eds ISTH and Leuven [Jniversity Press; Leuven: 1987: 525-547
  • 2 Green D, Hougie C, Kazmier FJ. et al Report of the working party on acquired inhibitors of coagulation: Studies of the “Lupus Anticoagulant”. Thromb Haemostas 1983; 49: 144-146
  • 3 Exner T, Tiiplett DA, Thberner D. et al Comparison of test methods for the lupus anticoagulant: International survey on lupus anticoagulants-I (ISLA-l). Thromb Haemostas 1990; 64: 478-484
  • 4 Machin S, Giddings SJ, Greaves M. et al Detection of lupus like anticoagulant: Current laboratory practice in the United Kingdom. J Clin Pathol 1990; 43: 73-75
  • 5 Triplett DA. Screening for the lupus anticoagulant. Res Clin Lab 1989; 19: 379-389
  • 6 Thiagarajan P, Pengo Y, Shapiro SS. The use of the dilute Russell’s viper venom time for the diagnosis of lupus anticoagulants. Blood 1986; 68: 869-884
  • 7 Exner T, Rickard KA, Kronenberg H. A sensitive test demonstrating lupus anticoagulant and its behavioural patterns. Br J Haematol 1978; 40: 143-151
  • 8 Schleider MA, Nachman RL, Jaffe EA. et al A clinical study of the lupus anticoagulant. Blood 1976; 48: 499-510
  • 9 Exner T, Papadopoulos G, Koutts J. Use of a simplified dilute Russell’s viper venom time (DRWT) confirms heterogeneity among “lupus anticoagulants”. Blood Coagul Fibrinolysis 1990; 1: 17-22
  • 10 Gibson J, Starling E, Date L. et al Simplified screening procedure for detecting lupus inhibitor. J Clin Pathol 1988; 41: 226-231
  • 11 Liu HW, Wong KL, Lin CK. et a1 The reappraisal of dilute tissue thromboplastin inhibition test in the diagnosis of lupus anticoagulant. Br J Haematol 1989; 72: 229-234
  • 1 Exner T. Comparison of two simple tests for the lupus anticoagulant. Am J Clin Pathol 1985; 83: 215-218
  • 13 Tiiplett DA, Brandt JT, Kaczor D. et al Laboratory diagnosis of lupus inhibitors: A comparison of the tissue thromboplastin inhibition procedure with a new platelet neutralization procedure. Am J Clin Pathol 1983; 79: 678-682
  • 14 Alving BM, Baldwin PE, Richards RL. et al The dilute phospholipid APTT: A sensitive assay for verification of lupus anticoagulants. Thromb Haemostas 1985; 54: 709-714
  • 15 Canoso RT, Zon Ll, Groopman JE. Anticardiolipin antibodies associated with HTLV-III infection. Br J Haematol 1987; 65: 495-498
  • 16 Chu P, Pendry K, Blecher TE. Detection of lupus anticoagulant in patients attending an anticoagulation clinic. Br Med J 1988; 297: 1449
  • 17 Rauch J, Tannenbaum M, Janoff AS. Distinguishing plasma lupus anticoagulants from antifactor antibodies using hexagonal (II) phase phospholipids. Thromb Haemostas 1989; 62: 892-896
  • 18 Lesperance B, David M, Rauch J. et al Relative sensitivity of different tests in the detection of low titer lupus anticoagulants. Thromb Haemostas 1988; 60: 217-219