Thromb Haemost 1979; 42(03): 848-854
DOI: 10.1055/s-0038-1666933
Original Article
Schattauer GmbH Stuttgart

A Simple Enzyme-Immunoassay (EIA) Test for Factor VIII-Related Antigen (VIIIAGN)

Paul M Ness
The Irwin Memorial Blood Bank of the San Francisco Medical Society, 270 Masonic Avenue, San Francisco, California 94118, U.S.A.
,
Herbert A Perkins
The Irwin Memorial Blood Bank of the San Francisco Medical Society, 270 Masonic Avenue, San Francisco, California 94118, U.S.A.
› Author Affiliations
Further Information

Publication History

Received 07 November 1978

Accepted 03 February 1979

Publication Date:
23 August 2018 (online)

Summary

An enzyme immunoassay (EIA) system has been developed to measure factor VIII- related antigen (VIIIAGN). This assay gives similar results to the commonly used Laurell electroimmunodiffusion (EID) assay for VIIIAGN as shown by comparison of both techniques with samples from healthy controls, patients with hemophilia A, and patients with von Willebrand’s disease. The assay also has a greater precision than the EID technique as demonstrated by multiple assays of aliquots of a single sample. The use of this EIA test for VIIIAGN is simple and employs inexpensive reagents and equipment. The use of expensive antisera is minimized. EIA for VIIIAGN has the advantage of increased sensitivity compared to Laurell EIA.

 
  • References

  • 1 Bartlett A, Dormandy KM, Hawkey CM, Stableforth P, Voller A. 1976; Factor VIII- related antigen: Measurement by enzyme immunoassay. British Medical Journal 1: 994
  • 2 Carlier Y, Bout D, Fruchart JD, Desreumeux C, Dewailly P, Sezille G, Jaillard J. 1978; Inhibition enzyme immunoassay. Application to human apolipoprotein B Journal of Immunological Methods 21: 317
  • 3 Engvall E, Perlmann P. 1972; Enzyme-linked immunoabsorbent assay, Elisa III. Quantitation of specific antibodies by enzyme labelled antiimmunoglobulin in antigen-coated tubes. Journal of Immunology 109: 129
  • 4 Guesdon JL, Avrameas S. 1976; Polyacrylamide-agarose beads for the preparation of effective immunoabsorbents. Journal of Immunological Methods 11: 129
  • 5 Hoyer LW. 1972; Immunologic studies of antihemophilia factor (AHF, factor VIII) IV. Radioimmunoassay of AHF antigen. Journal of Laboratory and Clinical Medicine 80: 822
  • 6 Leikola J, Perkins HA. 1978 a Antiglobulin test with enzyme immunoassay. Presented at the International Society of Blood Transfusion. Paris: 1978
  • 7 Leikola J, Perkins HA. 1978. b A simple and sensitive assay for the determination of low levels of IgA. Presented at the International Society of Blood Transfusion. Paris: 1978
  • 8 Ness PM, Hymas PG, Perkins HA. 1978; Re-evaluation of plasma from patients previously diagnosed as von Willebrand’s disease with the factor VIII-related antigen and Ristocetin cofactor assays. American Journal of Clinical Pathology 71: 26
  • 9 Schuurs AH W M, Van Weeman BK. 1977; Enzyme-immunoassay. Clinica Chimica Acta 81: 1
  • 10 Zimmerman TS, Ratnoff OD, Powell AE. 1971; Immunologic differentiation of classic hemophilia (factor VIII deficiency) and von Willebrand’s disease. Journal of Clinical Investigation 50: 244
  • 11 Zimmerman TS, Hoyer LW, Dickerson L. et al 1975; Determination of the von Willebrand’s disease antigen (factor VUI-related antigen) in plasma by quantitative immunoelectrophoresis. Journal of Laboratory and Clinical Medicine 86: 152
  • 12 Zimmerman TS, Abilgaard CF. 1978; Homozygous von Willebrand’s disease: Heterogeneous abnormalities of factor VIII antigen demonstrated by radioimmunoprecipitin techniques. Clinical Research 26: 509 A