CC BY-NC-ND 4.0 · J Neuroanaesth Crit Care 2020; 07(02): 110-112
DOI: 10.1055/s-0039-1688895
Case Report

Videolaryngoscope-Aided Electrode Placement for Lower Cranial Nerve Monitoring in a Child with Tonsillar Enlargement

Keta Thakkar
1   Department of Anaesthesiology, Christian Medical College, Vellore, Tamil Nadu, India
,
Georgene Singh
1   Department of Anaesthesiology, Christian Medical College, Vellore, Tamil Nadu, India
,
K. S. Babu
2   Department of Neurological Sciences, Christian Medical College Vellore, Tamil Nadu, India
› Author Affiliations

Abstract

Intraoperative neuromonitoring for tumor resection near brain stem consists of monitoring the lower cranial nerves (CNs) and motor evoked potentials to check for integrity of CN and corticospinal pathway. Usually CN mapping of CN VII (orbicularis oris/oculi and frontalis bilaterally), CN IX, CN X (posterior pharyngeal wall and soft palate bilaterally, vocal cords), CN XI (sternomastoid bilaterally), and CN XII (tongue bilaterally) is done. An intraoral pathology such as tonsillar enlargement especially in pediatric patients can pose a challenge to placement of the electrodes for CN monitoring. Videolaryngoscope will aid in better visualization and safe and precise placement of electrodes in the posterior pharyngeal wall, soft palate, vocal cords, and tongue. Thus, integration of different technologies aims to provide a safer and scientifically sound anesthetic technique and improves the outcome even in challenging situations.



Publication History

Article published online:
22 May 2019

© .

Thieme Medical and Scientific Publishers Private Ltd.
A-12, Second Floor, Sector -2, NOIDA -201301, India

 
  • References

  • 1 Jagannathan S, Krovvidi H. Anaesthetic considerations for posterior fossa surgery. Contin Educ Anaesth Crit Care Pain 2014; 14 (05) 203-206
  • 2 Highlander RL, Mcdaniel SL. Intraoperative monitoring of lower cranial nerves in surgery of the skull base. Operative Techniques in Otolaryngology 1996; 7 (02) 192-199
  • 3 Topsakal C, Al-Mefty O, Bulsara KR, Williford VS. Intraoperative monitoring of lower cranial nerves in skull base surgery: technical report and review of 123 monitored cases. Neurosurg Rev 2008; 31 (01) 45-53
  • 4 Kartush JM, Larouere MJ, Graham MD, Bouchard KR, Audet BV. Intraoperative cranial nerve monitoring during posterior skull base surgery. Skull Base Surg 1991; 1 (02) 85-92
  • 5 Mishler ET, Smith PG. Technical aspects of intraoperative monitoring of lower cranial nerve function. Skull Base Surg 1995; 5 (04) 245-250
  • 6 Grabb PA, Albright AL, Sclabassi RJ, Pollack IF. Continuous intraoperative electromyographic monitoring of cranial nerves during resection of fourth ventricular tumors in children. J Neurosurg 1997; 86 (01) 1-4
  • 7 Healy DW, Picton P, Morris M, Turner C. Comparison of the Glidescope, CMAC, Storz DCI with the Macintosh laryngoscope during simulated difficult laryngoscopy: a manikin study. BMC Anesthesiol 2012; 12: 11
  • 8 Ahmed SM, Doley K, Athar M, Raza N, Siddiqi OA, Ali S. Comparison of endotracheal intubation time in neutral position between C-Mac® and Airtraq® laryngoscopes: a prospective randomised study. Indian J Anaesth 2017; 61 (04) 338-343