CC BY-NC-ND 4.0 · Rev Bras Ortop (Sao Paulo) 2019; 54(06): 697-702
DOI: 10.1055/s-0039-1697015
Artigo Original
Sociedade Brasileira de Ortopedia e Traumatologia. Published by Thieme Revnter Publicações Ltda Rio de Janeiro, Brazil

Fixation of the Anterior Ligament Graft at the Tibial Pole: Biomechanical Analysis of Three Methods[*]

Article in several languages: português | English
Fernando Pessoa Weiss
1   Faculdade Evangélica do Paraná (FEPAR), Curitiba, Paraná, Brasil
,
Felipe Augusto de Aguiar Possoli
2   Programa de Pós-Graduação em Engenharia Mecânica e Materiais, Universidade Tecnológica Federal do Paraná (UTFPR), Curitiba, Paraná, Brasil
,
Isabel Ziesemer Costa
3   Departamento de Ortopedia e Traumatologia, Hospital de Clínicas, Universidade Federal do Paraná (UFPR), Curitiba, Paraná, Brasil
,
Paulo César Borges
4   Departamento de Mecânica, Universidade Tecnológica Federal do Paraná (UTFPR), Curitiba, Paraná, Brasil
,
5   Departamento de Ortopedia e Traumatologia, Universidade Federal do Paraná (UFPR), Curitiba, Paraná, Brasil
,
Luiz Fernando Kubrusly
1   Faculdade Evangélica do Paraná (FEPAR), Curitiba, Paraná, Brasil
› Author Affiliations
Further Information

Publication History

15 March 2018

28 May 2018

Publication Date:
13 December 2019 (online)

Abstract

Objective Comparative biomechanical analysis of tibial fixation strength for ligament reconstruction with interference screw compared with screw post and washer, and compared with the associated fixation of both methods (hybrid fixation).

Method A total of 54 specimens were used (porcine tibias and bovine flexor digital tendons), which were divided into three groups with fixation types similar to those used in anterior cruciate ligament (ACL) reconstruction: 1) fixation with interference screw; 2) fixation with screw post and toothed washer over knot and suture strand; and )- fixation with screw post and washer combined with interference screw (hybrid fixation). The analyses were performed through pull-out biomechanical tensile tests to determine the stiffness and load to system failure (yield load).

Results The hybrid fixation group presented a significantly higher final stiffness (59.10 ± 3.45 N/mm) in comparison to the other groups (p < 0.05) and a higher yield load (581.34 ± 33.48 N) compared to the interference screw group (p < 0.05).

Conclusion Hybrid fixation had biomechanical advantages over the bovine digital flexor graft fixation system in swine tibia during tensile tests.

* Study developed at Faculdade Evangélica do Paraná (FEPAR) and Universidade Tecnológica Federal do Paraná (UTFPR), Curitiba, Paraná, Brazil.


 
  • Referências

  • 1 Fu FH, Bennett CH, Lattermann C, Ma CB. Current trends in anterior cruciate ligament reconstruction. Part 1: Biology and biomechanics of reconstruction. Am J Sports Med 1999; 27 (06) 821-830
  • 2 Sanders TL, Maradit Kremers H, Bryan AJ. , et al. Incidence of Anterior Cruciate Ligament Tears and Reconstruction: A 21-Year Population-Based Study. Am J Sports Med 2016; 44 (06) 1502-1507
  • 3 Majewski M, Susanne H, Klaus S. Epidemiology of athletic knee injuries: A 10-year study. Knee 2006; 13 (03) 184-188
  • 4 Astur DC, Xerez M, Rozas J, Debieux PV, Franciozi CE, Cohen M. Lesões do ligamento cruzado anterior e do menisco no esporte: incidência, tempo de prática até a lesão e limitações causadas pelo trauma. Rev Bras Ortop 2016; 51 (06) 652-656
  • 5 Domnick C, Raschke MJ, Herbort M. Biomechanics of the anterior cruciate ligament: Physiology, rupture and reconstruction techniques. World J Orthop 2016; 7 (02) 82-93
  • 6 De Wall M, Scholes CJ, Patel S, Coolican MRJ, Parker DA. Tibial fixation in anterior cruciate ligament reconstruction: a prospective randomized study comparing metal interference screw and staples with a centrally placed polyethylene screw and sheath. Am J Sports Med 2011; 39 (09) 1858-1864
  • 7 Steiner ME, Hecker AT, Brown Jr CH, Hayes WC. Anterior cruciate ligament graft fixation. Comparison of hamstring and patellar tendon grafts. Am J Sports Med 1994; 22 (02) 240-246 , discussion 246–247
  • 8 Scheffler SU, Südkamp NP, Göckenjan A, Hoffmann RFG, Weiler A. Biomechanical comparison of hamstring and patellar tendon graft anterior cruciate ligament reconstruction techniques: The impact of fixation level and fixation method under cyclic loading. Arthroscopy 2002; 18 (03) 304-315
  • 9 Brand Jr J, Weiler A, Caborn DN, Brown Jr CH, Johnson DL. Graft fixation in cruciate ligament reconstruction. Am J Sports Med 2000; 28 (05) 761-774
  • 10 Prado M, Martín-Castilla B, Espejo-Reina A, Serrano-Fernández JM, Pérez-Blanca A, Ezquerro F. Close-looped graft suturing improves mechanical properties of interference screw fixation in ACL reconstruction. Knee Surg Sports Traumatol Arthrosc 2013; 21 (02) 476-484
  • 11 Rodeo SA, Arnoczky SP, Torzilli PA, Hidaka C, Warren RF. Tendon-healing in a bone tunnel. A biomechanical and histological study in the dog. J Bone Joint Surg Am 1993; 75 (12) 1795-1803
  • 12 Eguchi A, Ochi M, Adachi N, Deie M, Nakamae A, Usman MA. Mechanical properties of suspensory fixation devices for anterior cruciate ligament reconstruction: comparison of the fixed-length loop device versus the adjustable-length loop device. Knee 2014; 21 (03) 743-748
  • 13 Kousa P, Järvinen TLN, Vihavainen M, Kannus P, Järvinen M. The fixation strength of six hamstring tendon graft fixation devices in anterior cruciate ligament reconstruction. Part II: tibial site. Am J Sports Med 2003; 31 (02) 182-188
  • 14 Tetsumura S, Fujita A, Nakajima M, Abe M. Biomechanical comparison of different fixation methods on the tibial side in anterior cruciate ligament reconstruction: a biomechanical study in porcine tibial bone. J Orthop Sci 2006; 11 (03) 278-282
  • 15 Lee JJ, Otarodifard K, Jun BJ, McGarry MH, Hatch III GF, Lee TQ. Is supplementary fixation necessary in anterior cruciate ligament reconstructions?. Am J Sports Med 2011; 39 (02) 360-365
  • 16 Stieven Filho E, Malafaia O, Ribas-Filho JM. , et al. [Biomechanic analysis of the sewed tendons for the reconstruction of the anterior cruciate ligament]. Rev Col Bras Cir 2010; 37 (01) 52-57
  • 17 Woo SL, Hollis JM, Adams DJ, Lyon RM, Takai S. Tensile properties of the human femur-anterior cruciate ligament-tibia complex. The effects of specimen age and orientation. Am J Sports Med 1991; 19 (03) 217-225
  • 18 Scannell BP, Loeffler BJ, Hoenig M. , et al. Biomechanical comparison of hamstring tendon fixation devices for anterior cruciate ligament reconstruction: Part 2. Four tibial devices. Am J Orthop 2015; 44 (02) 82-85
  • 19 Trump M, Palathinkal DM, Beaupre L, Otto D, Leung P, Amirfazli A. In vitro biomechanical testing of anterior cruciate ligament reconstruction: traditional versus physiologically relevant load analysis. Knee 2011; 18 (03) 193-201
  • 20 Aga C, Rasmussen MT, Smith SD. , et al. Biomechanical comparison of interference screws and combination screw and sheath devices for soft tissue anterior cruciate ligament reconstruction on the tibial side. Am J Sports Med 2013; 41 (04) 841-848
  • 21 Donahue TL, Gregersen C, Hull ML, Howell SM. Comparison of viscoelastic, structural, and material properties of double-looped anterior cruciate ligament grafts made from bovine digital extensor and human hamstring tendons. J Biomech Eng 2001; 123 (02) 162-169
  • 22 Nagarkatti DG, McKeon BP, Donahue BS, Fulkerson JP. Mechanical evaluation of a soft tissue interference screw in free tendon anterior cruciate ligament graft fixation. Am J Sports Med 2001; 29 (01) 67-71
  • 23 Fabbriciani C, Mulas PD, Ziranu F, Deriu L, Zarelli D, Milano G. Mechanical analysis of fixation methods for anterior cruciate ligament reconstruction with hamstring tendon graft. An experimental study in sheep knees. Knee 2005; 12 (02) 135-138
  • 24 Zantop T, Weimann A, Rümmler M, Hassenpflug J, Petersen W. Initial fixation strength of two bioabsorbable pins for the fixation of hamstring grafts compared to interference screw fixation: single cycle and cyclic loading. Am J Sports Med 2004; 32 (03) 641-649
  • 25 Giurea M, Zorilla P, Amis AA, Aichroth P. Comparative pull-out and cyclic-loading strength tests of anchorage of hamstring tendon grafts in anterior cruciate ligament reconstruction. Am J Sports Med 1999; 27 (05) 621-625