CC BY-NC-ND 4.0 · Rev Bras Ortop (Sao Paulo) 2020; 55(02): 147-155
DOI: 10.1055/s-0039-3400738
Artigo Original
Asami
Sociedade Brasileira de Ortopedia e Traumatologia. Published by Thieme Revinter Publicações Ltda Rio de Janeiro, Brazil

Pain and Satisfaction Levels upon Removal of External Fixator at an Outpatient Facility[*]

Article in several languages: português | English
1   Departamento de Ortopedia e Traumatologia, Escola Paulista de Medicina, Universidade Federal de São Paulo (DOT-EPM/Unifesp), São Paulo, SP, Brasil
,
Flavio Kazuo Minami
1   Departamento de Ortopedia e Traumatologia, Escola Paulista de Medicina, Universidade Federal de São Paulo (DOT-EPM/Unifesp), São Paulo, SP, Brasil
,
Geraldo Kalif Lima
1   Departamento de Ortopedia e Traumatologia, Escola Paulista de Medicina, Universidade Federal de São Paulo (DOT-EPM/Unifesp), São Paulo, SP, Brasil
,
Vitor Spalatti
1   Departamento de Ortopedia e Traumatologia, Escola Paulista de Medicina, Universidade Federal de São Paulo (DOT-EPM/Unifesp), São Paulo, SP, Brasil
,
Hilário Boatto
1   Departamento de Ortopedia e Traumatologia, Escola Paulista de Medicina, Universidade Federal de São Paulo (DOT-EPM/Unifesp), São Paulo, SP, Brasil
,
Jose Lucarelli
1   Departamento de Ortopedia e Traumatologia, Escola Paulista de Medicina, Universidade Federal de São Paulo (DOT-EPM/Unifesp), São Paulo, SP, Brasil
› Author Affiliations
Further Information

Publication History

30 July 2018

18 December 2018

Publication Date:
23 March 2020 (online)

Abstract

Objective To quantify the levels of satisfaction and pain of patients submitted to external fixation removal without anesthesia at an outpatient facility.

Methods The present was a prospective study involving 28 patients using external fixators who answered 3 questionnaires associated with the Visual Analogue and Numerical Pain Scale during different moments of the removal.

Results The average pain prior to fixator removal was of 3.61. Shortly after the procedure, the patients reported that, on average, the most intense pain scored 6.68, and the least intense pain, 2.25 points. The average pain variation was of 4.43 points, and pain after 1 week scored, on average, 2.03 points. The recollection of the pain after fixator removal scored lower than the pain reported immediately after the procedure (mean value: 5.29). Most patients were middle-aged men, and 89.3% used circular external fixators. The main limb segment involved was the leg, and most patients (71.4%) had never used an external fixator before; they preferred the removal at an outpatient facility because it was faster (75%), and to avoid hospitalization (25%). The most intense pain was felt during the removal of Schanz pins (60.7%), being worse in the extremities of the limbs for 75% of the patients. An absolute majority of 85.7% was satisfied with the removal, and 82.1% stated that they would undergo the procedure again.

Conclusion External fixator removal at an outpatient facility without anesthesia is a well-tolerated option for patients, with good levels of approval and satisfaction.

* Study Performed At the Orthopedics and Traumatology Department (OTD) of Universidade Federal de São Paulo (Unifesp), São Paulo, Brazil.


 
  • Referências

  • 1 Sisk TD. General principles and techniques of external skeletal fixation. Clin Orthop Relat Res 1983; (180) 96-100
  • 2 Ilizarov GA. The Apparatus: components and biomechanical principles of application. In: Green S. , editor. Transosseus osteosynthesis. Theoretical and clinical aspects of the regeneration and growth of tissue. New York: Springer-Verlag; 1992: 63-136
  • 3 Morton A. Psychologic considerations in planning of staged reconstruction in limb deficiencies. In: Herring JA, Birch JG. , editors. The child with a limb deficiency. Rosemont, IL: Academy of Orthopaedic Surgeons; 1998: 119-204
  • 4 Patterson M. Impact of external fixation on adolescents: an integrative research review. Orthop Nurs 2006; 25 (05) 300-308
  • 5 Ryder S, Gorczyca JT. Routine removal of external fixators without anesthesia. J Orthop Trauma 2007; 21 (08) 571-573
  • 6 DiCicco JD, Ostrum RF, Martin B. Office removal of tibial external fixators: an evaluation of cost savings and patient satisfaction. J Orthop Trauma 1998; 12 (08) 569-571
  • 7 Pommer A, Muhr G, Dávid A. Hydroxyapatite-coated Schanz pins in external fixators used for distraction osteogenesis : a randomized, controlled trial. J Bone Joint Surg Am 2002; 84 (07) 1162-1166
  • 8 Johnson C. Measuring Pain. Visual Analog Scale Versus Numeric Pain Scale: What is the Difference?. J Chiropr Med 2005; 4 (01) 43-44
  • 9 Oldenmenger WH, van der Rijt CC. Feasibility of assessing patients' acceptable pain in a randomized controlled trial on a patient pain education program. Palliat Med 2017; 31 (06) 553-558
  • 10 Abulaiti A, Yilihamu Y, Yasheng T, Alike Y, Yusufu A. The psychological impact of external fixation using the Ilizarov or Orthofix LRS method to treat tibial osteomyelitis with a bone defect. Injury 2017; 48 (12) 2842-2846
  • 11 Yildiz C, Uzun O, Sinici E, Ateşalp AS, Ozşahin A, Başbozkurt M. [Psychiatric symptoms in patients treated with an Ilizarov external fixator]. Acta Orthop Traumatol Turc 2005; 39 (01) 59-63
  • 12 Jorge MH, Koizumi MS. Gastos governamentais do SUS com internações hospitalares por causas externas: análise no Estado de São Paulo, 2000. Rev Bras Epidemiol 2004; 7 (02) 228-238