J Knee Surg 2022; 35(12): 1378-1384
DOI: 10.1055/s-0041-1723972
Original Article

Clinical Outcomes and Experience of a Multiyear Consecutive Case Series of Total Knee Arthroplasty Procedures Conducted with a Bipolar Sealer System for Hemostasis

1   Sah Orthopaedic Associates, Institute for Joint Restoration, Center for Joint Replacement Bldg, Fremont, California
› Author Affiliations

Funding Database support for this study was provided by Medtronic.
Preview

Abstract

Maximizing hemostasis during total knee replacement procedures remains a key challenge in current practice. Bipolar sealer technology achieves intraoperative hemostasis through tissue sealing and coagulation with adjustable radio frequency energy and a saline-irrigated tip. Optimal surgical site hemostasis is important to avoid potential complications such as hemarthrosis, wound drainage, increased pain, delayed discharge, and readmissions. The aim of this study is to evaluate the safety and effectiveness of the bipolar sealer device in primary knee replacement in the largest consecutive series to date. A consecutive, treatment-control series of subjects who underwent a primary total knee arthroplasty (TKA) utilizing a bipolar sealer for hemostasis, one subgroup with concomitant tranexamic acid (TXA) administration (n = 1599) and one subgroup without TXA administration (n = 3582), compared with a control group of primary TKA under tourniquet only (n = 667). Statistical analyses were performed through two-tailed unpaired t-tests. There was less total postoperative drain output and a lower overall transfusion rate in the bipolar sealer group (807ml ± 428) (2.5%) than the tourniquet only group (1290 ± 658, p = 0.001) (8.4%, p = 0.0001), respectively. Drainage output in bipolar sealer + TXA (450 ± 297 ml) was lower than the other two groups (bipolar sealer 807 ± 428 mL, p = 0.0001; tourniquet only 1290 ± 658 ml, p = 0.0001). The bipolar sealer group had a higher hematocrit at postoperative day 1 (POD1) (bipolar sealer: 33.1 ± 4.3 cc, tourniquet only: 32.5 ± 4.3 cc, p = 0.001) and at discharge (POD2, bipolar sealer: 31.5 ± 3.7 cc, tourniquet only: 30.2 ± 3.9 cc, p = 0.0001). There were zero reported serious adverse events related to hemostasis management in any group. The bipolar sealer system is a safe and effective instrument to achieve intraoperative hemostasis during primary TKA. The bipolar sealer group required significantly fewer postoperative blood product transfusions and maintained a higher hematocrit concentration at the time of discharge compared with subjects treated solely with tourniquet mediated hemostasis. Addition of TXA to local hemostasis methods may further reduce blood loss and transfusion requirements.

Level of Evidence This is a Level III study.

Ethical Approval

This work was exempt from IRB approval.


Note

Surgical treatments, data collection, and data analysis were performed at Sah Orthopaedic Associates Institute for Joint Restoration.




Publication History

Received: 23 October 2020

Accepted: 02 January 2021

Article published online:
19 February 2021

© 2021. Thieme. All rights reserved.

Thieme Medical Publishers, Inc.
333 Seventh Avenue, 18th Floor, New York, NY 10001, USA