Open Access
CC BY 4.0 · Eur J Dent 2022; 16(02): 381-385
DOI: 10.1055/s-0041-1736388
Original Article

Influence of Voxel Size on CBCT Images for Dental Implants Planning

Ricardo Kehrwald
1   Department of Dentistry, Area of Implantology, Ingá Center University Maringa, Parana, Brazil
,
Hebert Sampaio de Castro
1   Department of Dentistry, Area of Implantology, Ingá Center University Maringa, Parana, Brazil
,
Samira Salmeron
1   Department of Dentistry, Area of Implantology, Ingá Center University Maringa, Parana, Brazil
,
Ricardo Alves Matheus
2   Department of Oral Medicine, Division of Oral Radiology, State University of Londrina, Londrina, Parana, Brazil
,
Gustavo Machado Santaella
3   Department of Diagnosis and Oral Health, Division of Oral Radiology, University of Louisville, Louisville, Kentucky, United States
,
Polyane Mazucatto Queiroz
4   Department of Dentistry, Division Oral Radiology, Area of Oral Radiology, Ingá Center University Maringa, Parana, Brazil
› Author Affiliations

Funding None.
Preview

Abstract

Objective This study was developed to evaluate the influence of voxel size on bone measurements for implant planning.

Materials and Methods The research was performed by using edentulous synthetic human mandibles with different levels of bone resorption. For each mandible, height and bone thickness were measured with a digital caliper. The PaX-i3d device was used to acquire the volumes of the five mandibles, with 50kVp, 4 mA, and a voxel size of 0.08 mm. After the acquisition, the images were reconstructed in the software CS three-dimensional Imaging, with four different sizes of voxels: 0.1, 0.2, 0.3, and 0.4 mm. All volumes were analyzed by a single evaluator who performed measurements to obtain bone height and thickness, using the reference points that were considered in obtaining the gold standard. The data were analyzed by ANOVA with a significance level of 5%.

Results There was no significant difference in the measurements obtained with different voxel sizes, both for bone height measurements and bone thickness. There was no statistically significant difference in measurements in thickness in comparison to the gold standard.

Conclusion When necessary, to measure height and bone thickness, it is possible to recommend voxel images of larger size (0.40 mm) without compromising the quality of the patient's clinical planning.



Publication History

Article published online:
13 December 2021

© 2021. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/)

Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India