Z Orthop Unfall 2017; 155(01): 61-66
DOI: 10.1055/s-0042-114704
Originalarbeit
Georg Thieme Verlag KG Stuttgart · New York

Tumorprothesen in der endoprothetischen Revisionschirurgie der unteren Extremität – Ergebnisse von 25 Patienten nach Versorgung mit einem modularen Tumor- und Revisionssystem (MUTARS®)

The Role of a Modular Universal Tumour and Revision System (MUTARS®) in Lower Limb Endoprosthetic Revision Surgery – Outcome Analysis of 25 Patients
J. Schmolders
1   Klinik und Poliklinik für Orthopädie und Unfallchirurgie, Universitätsklinikum Bonn
,
S. Koob
1   Klinik und Poliklinik für Orthopädie und Unfallchirurgie, Universitätsklinikum Bonn
,
P. Schepers
2   Orthopädie, Privatpraxis Schepers, Köln
,
S. Gravius
1   Klinik und Poliklinik für Orthopädie und Unfallchirurgie, Universitätsklinikum Bonn
,
D. C. Wirtz
1   Klinik und Poliklinik für Orthopädie und Unfallchirurgie, Universitätsklinikum Bonn
,
C. Burger
1   Klinik und Poliklinik für Orthopädie und Unfallchirurgie, Universitätsklinikum Bonn
,
P. H. Pennekamp
1   Klinik und Poliklinik für Orthopädie und Unfallchirurgie, Universitätsklinikum Bonn
,
A. C. Strauss
1   Klinik und Poliklinik für Orthopädie und Unfallchirurgie, Universitätsklinikum Bonn
› Institutsangaben
Weitere Informationen

Publikationsverlauf

Publikationsdatum:
15. September 2016 (online)

Zusammenfassung

Einleitung: Bei großen und gelenknahen knöchernen Defektsituationen nach vorangegangenen revisionsendoprothetischen Eingriffen besteht im Fall des erneuten Versagens die Möglichkeit der Versorgung durch modulare Implantatsysteme aus der tumorendoprothetischen Versorgung als sog. „Salvage Procedure“. Das Ziel der vorliegenden retrospektiven Studie ist die Evaluation von Patienten, die aufgrund großer und gelenknaher knöcherner Defektsituationen, welche nicht mit konventionellen Implantatsystemen versorgt werden konnten, hinsichtlich des klinisch-funktionellen Outcomes und der Komplikationsrate nach Implantation eines modularen Tumor- und Revisionssystems (MUTARS®, Firma Implantcast, Buxtehude, Deutschland).

Methodik: In unserer Klinik wurden im Zeitraum von 2005 bis 2014 insgesamt 25 Patienten mittels des MUTARS-Systems aufgrund einer konventionell nicht zu versorgenden ossären Defektsituation operativ revidiert. Der mittlere Nachbeobachtungszeitraum lag bei 16 Monaten (Spannweite: 12–72 Monate). Folgende Indikationen führten zum Revisionseingriff: Ein Patient stellte sich aufgrund einer gelockerten Kappenprothese mit Bildung eines Metallgranuloms vor, 2 Patienten mit einer Pseudarthrose nach Implantation eines Femurnagels, ein Patient mit einem „Cut-Out“ eines Femurnagels. Vier Patienten mussten aufgrund einer aseptischen und ein Patient aufgrund einer septischen Lockerung einer zuvor implantierten Endoprothese revidiert werden. Insgesamt wurden 6 Patienten aufgrund einer periprothetischen Fraktur revidiert. Weitere 10 Patienten wurden bei einer infektkonsolidierten Girdlestone-Situation nach Explantation einer Endoprothese aufgrund eines periprothetischen Infekts versorgt. Alle Patienten wurden in regelmäßigen Intervallen klinisch und radiologisch reevaluiert. Es wurden neben den Komorbiditäten der Patienten klinisch funktionelle-Parameter wie der Harris Hip Score erfasst. Des Weiteren wurde eine Outcome-Analyse bezüglich peri- und postoperativer Komplikationen und eine nativradiologische Verlaufsbeurteilung durchgeführt.

Ergebnisse: Insgesamt wurden 23 Patienten mit einem proximalen Femur versorgt. Drei Patienten erhielten zusätzlich zur Tumorprothese einen Beckenteilersatz aufgrund einer Beckendiskontinuität. Ein Patient wurde mit einem distalen Femur, und bei einem weiteren Patienten wurde das ganze Femur durch einen totalen Femurersatz endoprothetisch ersetzt. Die mittlere Krankenhausverweildauer lag bei 25 Tagen (Spannweite: 11–47 Tage). Wir verzeichneten eine Komplikationsrate von 24 %. Der Harris Hip Score stieg von 28 Punkten präoperativ auf 81 Punkte postoperativ.

Schlussfolgerung: Bei höhergradigen, knöchernen und gelenknahen Defektsituationen nach vorangegangener, gescheiterter endoprothetischer oder osteosynthetischer Versorgung, bietet das MUTARS-System eine suffiziente Versorgungsmöglichkeit mit modularer Adaptation an die jeweilige individuelle Defektkonstellation des Patienten. Die klinischen Ergebnisse sind im kurz- bis mittelfristigen Verlauf vielversprechend.

Abstract

Introduction/Background: With extended life expectancy, the number of primary joint arthroplasties has also increased. Revision surgery is also more often necessary, due to aseptic or septic loosening of the prosthesis or periprosthetic fracture. Large bone defects often occur in these patients and several non-modular, conventional implants are available to handle this difficult situation. Custom made implants offer an individually designed and defect-adapted shape with perfect covering of the lesion, but may delay the operation. The Modular Universal Tumor And Revision System (MUTARS®) offers the possibility to vary the length and angle of the femoral neck and the antetorsion angle. Thus, it permits intraoperative adaption to the individual patientʼs defect. The aim of our study is to present clinical, functional results and the rate of complications in a cohort of patients undergoing revision surgery for failed endoprosthetic replacement or failed trauma surgery, using the Modular Universal Tumor And Revision System with short-to midterm follow-up.

Patients and Methods: Between August 2005 and September 2014, 25 patients (17 female, 8 male) with an average age of 72 years (min. 56, max. 92 years) were included in a retrospective study using the MUTARS® system. The patients underwent surgical revision of osseous defects that were not susceptible to conventional care. The mean follow-up was 16 months (min. 12, max. 72 months). The indications which led to revision surgery were as follows: loosened metal-on-metal prosthesis with an acetabular defect caused by a metal-induced granuloma (n = 1), pseudoarthrosis after implantation of femur nail (n = 2), cut-out of a femur nail (n = 1), aseptic loosening of an implanted endoprosthesis (n = 4), septic loosening of an implanted endoprosthesis (n = 1), periprosthetic fracture (n = 6) and periprosthetic infection after two stage revision surgery (infection consolidated Girdlestone situation) (n = 10). All patients were followed up at regular intervals, both clinically and radiologically. Apart from comorbidities, clinical and functional parameters were measured, including the Harris Hip Score. An outcome analysis was also performed with respect to peri- and postoperative complications. Serial plain X-rays were followed-up.

Results: In all patients, stable reconstruction without the use of an allograft was possible. In total, 23 patients underwent surgery by using a proximal femur prosthesis; three patients also received a custom made acetabular component. One patient was treated by using a distal femur and one patient was treated by implantation of a total femur prosthesis. The average length of hospital stay was 25 days (min.11, max. 47 days). The Harris Hip Score improved from 28 points preoperatively to 81 points after surgery.In total we recorded 24 % of complications after surgery. Two patients suffered recurrent periprosthetic infection and the prosthesis had to be revised in a further two stage exchange; one patient had a tractus gap and was revised by surgery. Two patients suffered periprosthetic fracture due to trauma and the patient with the total femur prosthesis suffered recurrent periprosthetic infection of the silver – coated mega-prosthesis and committed suicide triggered by an episode of major depression.

Conclusion: Because of its modular nature, the Modular Tumor And Revision System (MUTARS®) can be used for highly variable intraoperative defect adaption. Good clinical and functional results were achieved in patients with excessive bone defects. However, the high rate of infection, even with silver coated mega-implants, is still a problem and should be studied further.

 
  • Literatur

  • 1 Dreinhöfer KE, Dieppe P, Stürmer T. et al. Indications for total hip replacement: comparison of assessments of orthopaedic surgeons and referring physicians. Ann Rheum Dis 2006; 65: 1346-1350
  • 2 Peersman G, Laskin R, Davis J. et al. Infection in total knee replacement: a retrospective review of 6489 total knee replacements. Clin Orthop Relat Res 2001; 392: 15-23
  • 3 Trampuz A, Zimmerli W. Diagnosis and treatment of implant-associated septic arthritis and osteomyelitis. Curr Infect Dis Rep 2008; 10: 394-403
  • 4 Marculescu CE, Berbari EF, Hanssen AD. et al. Outcome of prosthetic joint infections treated with debridement and retention of components. Clin Infect Dis 2006; 42: 471-478
  • 5 Pulido L, Ghanem E, Joshi A. et al. Periprosthetic joint infection: the incidence, timing, and predisposing factors. Clin Orthop Relat Res 2008; 466: 1710-1715
  • 6 Kurtz S, Ong K, Lau E. et al. Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030. J Bone Joint Surg Am 2007; 89: 780-785
  • 7 Paprosky WG, Cross MB. CORR Insights®: Validity and reliability of the Paprosky acetabular defect classification. Clin Orthop Relat Res 2013; 471: 2266
  • 8 Paprosky WG, Perona PG, Lawrence JM. Acetabular defect classification and surgical reconstruction in revision arthroplasty. A 6-year follow-up evaluation. J Arthroplasty 1994; 9: 33-44
  • 9 Friedrich MJ, Gravius S, Schmolders J. et al. [Biological acetabular defect reconstruction in revision hip arthroplasty using impaction bone grafting and an acetabular reconstruction ring]. Oper Orthop Traumatol 2014; 26: 126-140
  • 10 Friedrich MJ, Schmolders J, Michel RD. et al. Management of severe periacetabular bone loss combined with pelvic discontinuity in revision hip arthroplasty. Int Orthop 2014; 38: 2455-2461
  • 11 Wimmer MD, Randau TM, Deml MC. et al. Impaction grafting in the femur in cementless modular revision total hip arthroplasty: a descriptive outcome analysis of 243 cases with the MRP-TITAN revision implant. BMC Musculoskelet Disord 2013; 14: 19
  • 12 Schmolders J, Friedrich MJ, Michel RD. et al. Acetabular defect reconstruction in revision hip arthroplasty with a modular revision system and biological defect augmentation. Int Orthop 2015; 39: 623-630
  • 13 Schmolders J, Friedrich MJ, Michel R. et al. Validation of the Charlson comorbidity index in patients undergoing revision total hip arthroplasty. Int Orthop 2015; 39: 1771-1777
  • 14 Peters CL, Curtain M, Samuelson KM. Acetabular revision with the Burch-Schnieder antiprotrusio cage and cancellous allograft bone. J Arthroplasty 1995; 10: 307-312
  • 15 DeLee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res 1976; 121: 20-32
  • 16 Henderson ER, OʼConnor MI, Ruggieri P. et al. Classification of failure of limb salvage after reconstructive surgery for bone tumours: a modified system Including biological and expandable reconstructions. Bone Joint J 2014; 96-B: 1436-1440
  • 17 Wirtz DC, Heller KD, Holzwarth U. et al. A modular femoral implant for uncemented stem revision in THR. Int Orthop 2000; 24: 134-138
  • 18 Wirtz DC, Niethard FU. [Etiology, diagnosis and therapy of aseptic hip prosthesis loosening – a status assessment]. Z Orthop Ihre Grenzgeb 1997; 135: 270-280
  • 19 Malchau H, Herberts P, Ahnfelt L. Prognosis of total hip replacement in Sweden. Follow-up of 92,675 operations performed 1978–1990. Acta Orthop Scand 1993; 64: 497-506
  • 20 Engh CA, Glassman AH, Griffin WL. et al. Results of cementless revision for failed cemented total hip arthroplasty. Clin Orthop Relat Res 1988; 235: 91-110
  • 21 Hedley AK, Gruen TA, Ruoff DP. Revision of failed total hip arthroplasties with uncemented porous-coated anatomic components. Clin Orthop Relat Res 1988; 235: 75-90
  • 22 Wagner H, Wagner M. [Femur revision prosthesis]. Z Orthop Ihre Grenzgeb 1993; 131: 574-577
  • 23 Deml MC, Buhr M, Wimmer MD. et al. CT-guided infiltration saves surgical intervention and fastens return to work compared to anatomical landmark-guided infiltration in patients with lumbosciatica. Eur J Orthop Surg Traumatol 2015; 25 (Suppl. 01) S177-S182
  • 24 Wraighte PJ, Howard PW. Femoral impaction bone allografting with an Exeter cemented collarless, polished, tapered stem in revision hip replacement: a mean follow-up of 10.5 years. J Bone Joint Surg Br 2008; 90: 1000-1004
  • 25 Frances A, Moro E, Cebrian JL. et al. Reconstruction of bone defects with impacted allograft in femoral stem revision surgery. Int Orthop 2007; 31: 457-464
  • 26 Schmale GA, Lachiewicz PF, Kelley SS. Early failure of revision total hip arthroplasty with cemented precoated femoral components: comparison with uncemented components at 2 to 8 years. J Arthroplasty 2000; 15: 718-729
  • 27 Yoo JJ, Kwon YS, Koo KH. et al. One-stage cementless revision arthroplasty for infected hip replacements. Int Orthop 2009; 33: 1195-1201
  • 28 Blackley HR, Davis AM, Hutchison CR. et al. Proximal femoral allografts for reconstruction of bone stock in revision arthroplasty of the hip. A nine to fifteen-year follow-up. J Bone Joint Surg Am 2001; 83-A: 346-354
  • 29 Tanzer M, Chan S, Brooks CE. et al. Primary cementless total hip arthroplasty using a modular femoral component: a minimum 6-year follow-up. J Arthroplasty 2001; 16: 64-70
  • 30 Gustilo RB, Pasternak HS. Revision total hip arthroplasty with titanium ingrowth prosthesis and bone grafting for failed cemented femoral component loosening. Clin Orthop Relat Res 1988; 235: 111-119
  • 31 Malkani AL, Sim FH, Chao EY. Custom-made segmental femoral replacement prosthesis in revision total hip arthroplasty. Orthop Clin North Am 1993; 24: 727-733