Open Access
CC BY 4.0 · The Arab Journal of Interventional Radiology 2023; 07(01): 031-034
DOI: 10.1055/s-0043-1763499
Original Article

IVC Filter Retrieval before and after Implementation of IVC Filter Retrieval Alert System (IFRAS): A Single-Center Experience

Authors

  • Hassan Aljaziri

    1   Department of Medical Imaging, Division of Vascular Interventional Radiology, King Abdullah International Medical Research Center, College of Medicine, King Saud bin Abdulaziz University for Health Sciences, Ministry of the National Guard Health Affairs, Riyadh, Saudi Arabia
  • Refaat Salman

    1   Department of Medical Imaging, Division of Vascular Interventional Radiology, King Abdullah International Medical Research Center, College of Medicine, King Saud bin Abdulaziz University for Health Sciences, Ministry of the National Guard Health Affairs, Riyadh, Saudi Arabia
  • Naila A. Shaheen

    2   Department of Biostatistics and Bioinformatics, King Abdullah International Medical Research Center, Riyadh, Saudi Arabia
    3   King Saud Bin Abdulaziz University for Health Sciences, Riyadh, Saudi Arabia
    4   Ministry of National Guard Health Affairs, Riyadh, Saudi Arabia
  • Mohammad Alaftan

    1   Department of Medical Imaging, Division of Vascular Interventional Radiology, King Abdullah International Medical Research Center, College of Medicine, King Saud bin Abdulaziz University for Health Sciences, Ministry of the National Guard Health Affairs, Riyadh, Saudi Arabia

Funding None.
Preview

Abstract

Objective The aim of this study was to evaluate the effectiveness of the IVC filter retrieval alert system (IFRAS) in increasing the inferior vena cava (IVC) filter retrieval rate.

Materials and Methods This study was a case-based retrospective study, for patients who had IVC filter insertion from January 2013 to December 2019 with a sample of 756 patients. The sample was divided into two groups for filter retrieval rate: before the implementation of the tracking system (IFRAS) between 2013 and 2015 with a sample of 321 patients, and after the implementation of the tracking system (IFRAS) between 2016 and 2019 with a sample of 435 patients. This study aimed to compare the IVC filter retrieval rate before and after the implementation of the IFRAS. The tracking system (IFRAS) protocol was applied by a dedicated employee who is actively tracking patients and strictly following them up with a referred physician or interventional radiologist through the interventional radiology clinic.

Results The IVC filter retrieval before the implementation of the tracking system (2013–2015) was 38.3% (123/321), and it became 54.25% (236/435) after the implementation of the tracking system with a p-value less than 0.001. Before implementing the tracking system, patients with no follow-up after IVC filter insertion were 45.17% (145/321), and this decreased to 41.15% (179/435) after implementing the tracking system.

Conclusion The study proved a statistically significant difference in increasing the IVC filter retrieval rate after implementing the IFRAS.



Publikationsverlauf

Artikel online veröffentlicht:
11. April 2023

© 2023. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/)

Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India