Case Presentation: A 55-year-old women she presented with clinical symptoms suggestive of progressive angina for the past few months was admitted to our hospital for the evaluation of exertional angina. She had an unremarkable medical history, high blood pressure being his sole cardiovascular risk factor. clinical examination on admission revealed stable patient with an arterial pressure of 150/80. The electrocardiogram showed the presence of a negative anterior T wave. After initial therapy with Aspegic 100 mg, bisoprolol 5 mg, statin and its treatment of hypertension, He was referred for coronary angiography and possible coronary revascularization. The patient had selective coronary angiography, which exhibited, 80% diameter stenosis of the mid-portion of the left anterior descending (LAD) coronary artery. After reviewing the patient’s anatomy, it was felt that the LAD were the cause of the patient’s clinical syndrome. Intervention was performed. Systemic heparin (5,000 IU) was administered. The patient was scheduled for angioplasty the following day with a loading dose of clopidogrel. Direct stenting of the mid LAD was performed with a 2.75 mm diameter, 26 mm length Resolute integrity stent, and after a control angiography, the stent was found to be under-expanded, a 3 mm balloon (Medtronic Euphora) was advanced over the guidewire in the LAD. After two inflations at a maximal pressure of 18 bar, the balloon was withdrawn and a control injection was made. This showed patency of the middle segment of the LAD, however, with a “no flow” situation and an important extravasation of the contrast medium into the pericardium (Fig. 1). Immediately appreciated. The 2.0 mm balloon was moved 2 mm more proximal and inflated at 3 atm to seal the leak. This was confirmed by contrast injection. A trans-thoracic cardiac echo was performed emergently. The clinical course deteriorated quickly and fatal cardiac arrest ensued, in immediate a filling with a 100 mL puncture was performed. Despite resuscitation measures, the patient could not be retrieved. A total rupture of the vascular wall had occurred 2 cm more distally (Fig. 2).

Discussion: Coronary artery rupture is a relatively uncommon but morbid complication of PCI. This complication can be particularly difficult to treat in the setting of combined anticoagulant (heparin) and antiplatelet therapy with glycoprotein IIb/IIIa inhibitors. Cardiac tamponade and death may result from this complication, even when it is recognized and treated in a timely fashion. The key to treatment is the immediate recognition and sealing of the rupture by balloon inflation. If this is done in a timely fashion, in our case we tried to use a balloon but the rupture was wide but in some cases with balloon, the pericardial leak can be minimized, and tamponade can be avoided. Most immediate referral for open cardiac surgery is required to ligate the coronary rupture, with or without the need for coronary artery bypass grafting. There are very limited less-invasive solutions to try to deal with the problem of coronary rupture. If the ruptured vessel is large and supplies a substantial myocardial territory, it may be possible to seal the rupture using a covered stent. In addition, the use of covered stents has been associated with a relatively high risk of stent thrombosis and myocardial infarction. In vessels that are too small to be treated with a covered stent, surgery has been the mainstay for treatment of coronary artery rupture. Similarly, surgery is typically the treatment of choice if there is a rupture after a proximal opening of a CTO. For very small, distal perforations, there have been several approaches used to seal the coronary leak and avoid surgery. Thrombin, gelfoam, microcoil embolization, and organized thrombus, obtained from the patient's own blood, have all been used successfully to treat these small distal perforations. With only 11 papers between 1982 and 1991 in the literature. The National Heart, Lung, and Blood Institute registry on PTCA reports two cases of perforation and one case of coronary artery rupture without further information. A detailed case history of 14 patients is available?-” Coronary artery perforation and rupture were reported to occur in the LAD (5 patients), a diagonal branch (7 patients), and the RCA (2 patients). In the setting of rupture of a CTO, it may be possible to use this approach with minimal risk of myocardial necrosis. Most auteurs do not clearly distinguish coronary artery perforation from rupture, although it seems appropriate to define perforation as a benign condition, mostly caused by subintimal penetration of the guidewire, not inducing hemodynamic changes, and treatable in a conservative way. Coronary artery rupture is a more serious condition caused by balloon rupture, a subintimal balloon inflation, or the use of balloon that is too large with respect to the diameter of the vessel (balloon–artery mismatch). Rupture leads to dramatic hemodynamic changes inducing coronary subocclusion and tamponade and requires urgent surgical intervention.

Conclusion: Coronary artery rupture is a rare but major complication. One should be aware of this potential complication as a greater number of recanalization's will no doubt be performed in the future. Leaving the balloon inflated at the site of the rupture, pericardiocentesis and coronary artery ligation or emergency CABG seem to be the therapies of choice.