Z Geburtshilfe Neonatol 2003; 207(3): 79-83
DOI: 10.1055/s-2003-40972
Originalarbeit
© Georg Thieme Verlag Stuttgart · New York

Nackentransparenz-Messung - eine effektive Untersuchung zur Früherkennung fetaler Erkrankungen?

Nuchal Translucency Measurement - an Effective Method for Early Recognition of Fetal Disease?S. Böhmer1 , S. Lampe1 , P. Blümel1
  • 1Frauenklinik des Klinikum Osnabrück GmbH
Further Information

Publication History

Eingereicht: 15.6.2002

Angenommen nach Überarbeitung: 5.3.2003

Publication Date:
31 July 2003 (online)

Zusammenfassung

Hintergrund: In den letzten Jahren sind immer mehr Erfahrungen in der Messung der Nackentransparenz (nuchal translucency = NT) des Feten in der Frühschwangerschaft gesammelt worden. Es fiel auf, dass zwar alle Feten zwischen der 11. und 14. Schwangerschaftswoche (SSW) eine messbare Flüssigkeitsansammlung im Nackenbereich ausbilden, dass jedoch insbesondere Feten mit Chromosomenstörungen, kongenitalen Herzfehlern und Syndromen überdurchschnittlich häufig eine erhöhte NT aufweisen.

Ziel: Unter Aufarbeitung unseres eigenen Patientengutes der letzten zwei Jahre soll die Frage beleuchtet werden, ob die NT-Messung eine effektive Untersuchung zur Früherkennung fetaler Problematiken darstellt.

Patientinnen und Methode: Bis Februar 2002 wurden bei 199 Feten NT-Messungen durchgeführt, standardisiert nach den Richtlinien der Fetal Medicine Foundation in London, an deren Multizenterstudie wir teilnehmen. Die Patientinnen stammten aus unserer Abteilung für pränatale Diagnostik und Therapie und waren uns von auswärts zugewiesen worden.

Ergebnisse: Bei 152 Feten wurde eine NT im Normbereich gemessen, bei 47 Feten war die NT oberhalb der Norm. Von den Feten mit erhöhter NT wiesen 7 Feten eine Chromosomenstörung auf, 1 Fet hatte einen Herzfehler, 3 Feten eine anderweitige Organfehlbildung und bei 3 Feten wurde ein Syndrom festgestellt. Bei den NT-Messungen, die im Normbereich lagen, hatte kein Fet eine der oben genannten Problematiken.

Schlussfolgerung: Damit zeigt sich auch an diesem noch recht kleinen Kollektiv, dass die NT-Messung ein sehr effektiver Filter zur Erkennung bestimmter fetaler Erkrankungen in der frühen Fetalperiode ist.

Abstract

Background: In recent years, an increasing amount of experience has been collected in measuring the nuchal translucency (NT) of the fetus in early pregnancy. While all fetuses develop a measurable collection of fluid in the area of the neck between the 11th and 14th weeks of pregnancy, the fact that fetuses with chromosomal disorders, cardiac defects, and syndromal diseases, in particular, reveal an above-average incidence of increased NT has been noticed.

Objective: By processing our own patient data from the past two years, we intend to elucidate the question of whether NT measurement is a sensible investigation for the early detection of fetal problems.

Patients and method: NT measurements were carried out in 199 fetuses; these measurements were standardized according to the guidelines of the Foetal Medicine Foundation in London, in whose multicentric study we are participating. The patients were under the care of our prenatal diagnosis and therapy department and were referred to us from external sources.

Results: NT within the reference range was determined in 152 fetuses; NT exceeded the reference value in 47 fetuses. Of those fetuses with increased NT, 7 fetuses revealed a chromosomal anomaly, 1 foetus was suffering from a cardiac defect, 3 fetuses were suffering from other organ abnormalities, and 3 fetuses were determined to be suffering from syndromal disease. None of the fetuses whose NT measurements were within the reference range was discovered to be suffering from any of the above-mentioned problems.

Conclusion: Even this relatively small group of patients reveals that NT measurement is a very effective filter for detecting certain fetal diseases during the early fetal period.

Literatur

  • 1 Gasiorek-Wiens A, Tercanli S, Kozlowski P, Kossakiewicz A, Minderer S, Meyberg H, Kamin G, Germer U, Bielicki M, Hackelöer B J, Sarlay D, Kuhn P, Klapp J, Bahlmann F, Pruggmeyer M, Schneider K TM, Seefried W, Fritzer E, von Kaisenberg C S. Screening for trisomy 21 by fetal nuchal translucency and maternal age: Multicentre project in Germany, Austria and Switzerland.  Ultrasound Obstet Gynaecol. 2001;  18 645-48
  • 2 Hyett J, Perdu M, Sharland G, Snijders R J, Nicolaides K H. Using fetal nuchal translucency to screen for major congenital cardiac defects at 10 - 14 weeks of gestation. Population based cohort study.  BMJ. 1999;  318 81-5
  • 3 Nicolaides K H, Sebire N J, Snijders J M. The 11 - 14-week scan. The Partenon Publishing Group New York London 1999
  • 4 Sebire N J, Snijders R J, Brown R, Southall T, Nicolaides K H. Detection of sex chromosome abnormalities by nuchal translucency screening at 10 - 14 weeks.  Prenat Diagn. 1998;  18 581-4
  • 5 Snijders R J, Noble P, Sebire N J, Souka A P, Ncolaides K H. UK multicentre project on assessment of risk of trisomy 21 by maternal age and fetal nuchal translucency thickness at 10 - 14 weeks of gestation. Fetale medicine Foundation First Trimester Screening Group.  Lancet. 1998;  352 343-346
  • 6 Snijders R J, Sebire N J, Najar R, Souka A P, Nicolaides K H. Increased nuchal translucency in trisomy 13 fetuses at 10 - 14 weeks of gestation.  Am J Med Genet. 1999;  86 205-7
  • 7 Souka A P, Snijders R J, Novakov A, Soares W, Nicolaides K H. Defects and syndromes in chromosomally normal fetuses with increased nuchal translucency thickness at 10 - 14 weeks of gestation.  Ultrasound Obstet Gynaecol. 1998;  11 391-400
  • 8 Tul N, Spencer K, Noble P, Chan C, Nicolaides K H. Screening for trisomy 18 by fetal nuchal translucency and maternal serum free beta hCG and PAPP-A at 10 - 14 weeks of gestation.  Praenat Diag. 1999;  19 1035-42
  • 9 Zosmer N, Souter V L, Chan C S, Huggon I C, Nicolaides K H. Early diagnosis of major cardiac defects in chromosomally normal fetuses with increased nuchal translucency.  Br J Obstet Gynaecol. 1999;  106 829-33

Priv.-Doz. Dr. Stephan Böhmer

Frauenklinik des Klinikum Osnabrück

Am Finkenhügel 1

49076 Osnabrück

    >