Abstract
Objective: The characteristics of an ideal contrast agent for use in the intraoperative MRI
would be tumor-specificity and intracellular localization, combined with extended
tumor enhancement, but with rapid elimination from the blood. The radiation sensitizing
properties of Motexafin gadolinium (MGd) have been investigated in a number of clinical
trials involving patients with brain metastases. These studies clearly show that MGd
is detectable in magnetic resonance images many days following administration. The
aim of this experimental study was to test whether Motexafin gadolinium (MGd) could
serve as an efficient intraoperative contrast agent avoiding problems that arise with
surgically induced intracranial enhancement.
Methods: F98 orthotopic brain tumors or surgical lesions were induced in Fisher rats. T1-weighted MRI studies were performed with either a single or multiple daily doses
of MGd. The last contrast dose was administered either 7 or 24 hours prior to scanning
in both tumor-bearing or surgically-treated animals. All scans were T1-weighted nce (TR=495 ms; TE=1 ms.) with a slice thickness of 1.0 mm. Three tubes
containing 2.3, 0.23 and 0.023 mg/mL of MGd (in physiological saline) respectively,
were used as standards to calibrate the scans.
Results: Animals receiving either 30 or 60 mg/kg MGd i.v. developed clinical signs of impaired
motor activity, and increasing lethargy and were euthanized 48 hours after MGd administration
due to their poor and deteriorating condition. MGd given i.p. was tolerated up to
a dose of 140 mg/kg. Despite multiple dosages and several administration modes (i.p.,
i.v.) no significant enhancement was observed if the scans were performed 7 or 24
hours following the last MGd dose. Clear enhancement was seen though when the scans
were performed 30 min following MGd administration, indicating that the agent was
being taken up by the tumor. Scans of necrotic lesions though were positive though
7 hours following MGd injection. MGd scans had no significant enhancement following
surgically-induced lesions while scans with conventional contrast agents showed both
meningeal and intraparenchymal enhancement.
Conclusion: This study suggests that MGd is not sequestered in viable tumor for the necessary
time interval required to allow delayed imaging in this model. The agent does seem
to remain in necrotic tissue for longer time intervals. MGd therefore would not be
suitable as a contrast agent in intraoperative MRI for the detection of remaining
tumor tissue during surgery.
Key words
motexafin - intraoperative MRI - surgically-induced contrast - rat brain tumor
References
- 1
Albert FK, Forsting M, Sartor K. et al .
Early postoperative magnetic resonance imaging after resection of malignant glioma:
objective evaluation of residual tumor and its influence on regrowth and prognosis.
Neurosurgery.
1994;
34
45-61
- 2
Yoshida J, Kajita Y, Wakabayashi T. et al .
Long-term follow-up results of 175 patients with malignant glioma: importance of radical
tumour resection and postoperative adjuvant therapy with interferon, ACNU and radiation.
Acta Neurochir.
1994;
127
55-59
- 3
Lacroix M, Abi-Said D, Fourney DR, Gokaslan ZL, Shi W, De Monte F, Lang FF, MacCutcheon IE,
Hassenbusch SJ, Holland E, Hess K, Michael C, Miller D, Sawaya R.
A multivariate analysis of 416 patients with glioblastoma multiforme: prognosis, extent
of resection, and survival.
J Neurosurg.
2001;
95
190-198
- 4
Stummer W, Pichlmeier U, Meinel T, Wiestler O, Zanella F, Reulen H.
Fluorescence-guided surgery with 5-aminolevulinic acid for resection of malignant
glioma: a randomised controlled multicentre phase III trial.
Lancet Oncol.
2006;
7
392-401
- 5
Hirschberg H, Samset E, Hole PK, Lote K.
Impact of intraoperative MRI on the results of surgery for high grade gliomas.
Minim Invas Neurosurg.
2005;
48
77-84
- 6
Wirtz CR, Knauth M, Staubert A, Bonsanto MM, Sartor K, Kunze S, Tronnier VM.
Clinical evaluation and follow-up results for intraoperative magnetic resonance imaging
in neurosurgery.
Neurosurgery.
2000;
46
1112-1120
- 7
Lunsford LD, Kondziolka D, Bissonette DJ.
Intraoperative imaging of the brain.
Stereotact Funct Neurosurg.
1996;
66
58-64
- 8
Hammoud MA, Ligon BL, el Souki R. et al .
Use of intraoperative ultrasound for localizing tumors and determining the extent
of resection. A comparative study with magnetic resonance imaging.
J Neurosurg.
1996;
84
737-774
- 9
Hirschberg H, Unsgaard G.
Incorporation of ultrasonic imaging in an optically coupled frameless stereotatic
system.
Acta Neurochirurgica.
1997;
68
75-80
- 10
Gronningsaeter A, Kleven A, Ommedal S, Aarseth TE, Lie T, Lindseth F, Lango T, Unsgard G.
SonoWand, an ultrasound-based neuronavigation system.
Neurosurgery.
2000;
47
1373-1379
- 11
Hirschberg H, Samset E.
Intraoperative image directed dye marking of tumor margins.
Minim Invas Neurosurg.
1999;
42
123-127
- 12
Dietrich J, Schneider JP, Schulz T. et al .
Intraoperative appearance of the resection area in brain-tumor operations in an open
0.5 MRT.
Radiologe.
1998;
38
935-942
- 13
Knauth M, Aras N, Wirtz CR. et al .
Surgically induced intracranial contrast enhancement. Potential source of error in
intraoperative MRI.
AJNR Am J Neuroradiol.
1999;
20
1547-1553
- 14
Knauth M, Egelhof T, Roth SU, Wirtz CR, Sartor K.
Monocrystalline iron oxide nanoparticles: possible solution to the problem of surgically
induced intracranial contrast enhancement in intraoperative MR imaging.
AJNR Am J Neuroradiol.
2001;
22
99-102
- 15
Varallyay P, Nesbit G, Muldoon LL, Nixon RR, Delashaw J, Cohen JI, Petrillo A, Rink D,
Neuwelt EA.
Comparison of two superparamagnetic viral-sized iron oxide particles ferumoxides and
ferumoxtran-10 with a gadolinium chelate in imaging intracranial tumors.
AJNR Am J Neuroradiol.
2002;
23
510-519
- 16
Kircher MF, Mahmood U, King RS, Weissleder R, Josephson L.
A multimodal nanoparticle for preoperative magnetic resonance imaging and intraoperative
optical brain tumor delineation.
Cancer Research.
2003;
63
8122-8125
- 17
Sessler JL, Murai T, Hemmi G.
A water-stable gadolinium(III) complex derived from a new pentadentate expanded porphyrin
ligand.
Inorg Chem.
1989;
28
3390-3393
- 18
Sessler JL, Burrell AK.
Expanded porphyrins.
Top Curr Chem.
1992;
161
177-273
- 19
Young SW, Qing F, Harriman A. et al .
Gadolinium(III) texaphyrin: a tumor selective radiation sensitizer that is detectable
by MRI.
Proc Natl Acad Sci USA.
1996;
93
6610-6615
- 20
Sessler JL, Mody TD, Hemmi GW. et al .
Gadolinium(III) texaphyrin: a novel MRI contrast agent.
J Am Chem Soc.
1993;
115
10368-10369
- 21
Young SW, Sidhu MK, Qing F. et al .
Preclinical evaluation of gadolinium(III) texaphyrin complex.
Inv Radiol.
1994;
29
330-338
- 22
Wu GN, Ford JM, Alger JR.
MRI measurement of the uptake and retention of motexafin gadolinium in glioblastoma
multiforme and uninvolved normal human brain.
J Neuro-Oncol.
2006;
77
95-103
- 23
Carde P, Timmerman R, Mehta MP. et al .
Multicenter phase Ib/II trial of the radiation enhancer motexafin gadolinium in patients
with brain metastases.
J Clin Oncol.
2001;
19
2074-2083
- 24
De Stasio G, Rajesh D, Ford JM. et al .
Motexafin-gadolinium taken up in vitro by at least 90% of glioblastoma cell nuclei.
Clin Cancer Res.
2006;
12
206-213
- 25
Ko L, Koestner A, Wechsler W.
Characterization of cell cycle and biological parameters of transplantable glioma
cell lines and clones.
Acta Neuropathol.
1980;
51
107
- 26
Goodman JH, MacGregor JM, Clendenon NR, Gahbauer RA, Barth RF, Soloway AH, Fairchild RG.
Inhibition of tumor growth in a glioma model treated with boron neutron capture therapy.
Neurosurgery.
1990;
27
383
- 27
Angell-Petersen E, Madsen SJ, Spetalen S, Sun CH, Peng Q, Carper SW, Hirschberg H.
Influence of light fluence rate on the effects of photodynamic therapy in an orthotopic
rat glioma model.
J Neurosurg.
2006;
104
109-117
- 28
Hunt MA, Bago AG, Neuwelt EA.
Single-dose contrast agent for intraoperative MR imaging of intrinsic brain tumors
by using ferumoxtran-10 AJNR.
Am J Neuroradiol.
2005;
26
1084-1088
- 29
Veiseh O, Sun C, Gunn J, Kohler N, Gabikian P, Lee D, Bhattarai N, Ellenbogen R, Sze R,
Hallahan A, Olson J, Zhang M.
Optical and MRI multifunctional nanoprobe for targeting gliomas.
Nano Lett.
2005;
5
1003-1008
- 30
Lyons SA, O’Neal J, Sontheimer H.
Chlorotoxin, a scorpion-derived peptide, specifically binds to gliomas and tumors
of neuroectodermal origin.
Glia.
2002;
39
162-173
- 31
Tréhin R, Figueiredo J-L, Pittet 2 MJ, Weissleder R, Josephson L, Mahmood U.
Fluorescent nanoparticle uptake for brain tumor visualization.
Neoplasia.
2006;
8
302-311
- 32
Woodburn KW.
Intracellular localization of the radiation enhancer motexafin gadolinium using interferometric
Fourier fluorescence microscopy.
J Pharmacol Exp Ther.
2001;
297
888-894
- 33
Viala J, Vanel D, Meingan P. et al .
Phases IB and II multidose trial of gadolinium texaphyrin, a radiation sensitizer
detectable at MR imaging: preliminary results in brain metastases.
Radiology.
1999;
212
755-759
- 34
Mehta MP, Shapiro WR, Glantz MJ. et al .
Lead-in phase to randomized trial of motexafin gadolinium and whole-brain radiation
for patients with brain metastases: centralized assessment of magnetic resonance imaging,
neurocognitive, and neurologic end points.
J Clin Oncol.
2002;
20
3445-3453
- 35
Mehta MP, Rodrigus P, Terhaard CH. et al .
Survival and neurologic outcomes in a randomized trial of motexafin gadolinium and
whole-brain radiation therapy in brain metastases.
J Clin Oncol.
2003;
21
2529-2536
- 36
Meyers CA, Smith JA, Bezjak A. et al .
Neurocognitive function and progression in patients with brain metastases treated
with whole-brain radiation and motexafin gadolinium: results of a randomized phase
III trial.
J Clin Oncol.
2004;
22
157-165
- 37
Rosenthal DI, Nurenberg P, Becerra CR. et al .
A Phase I single dose trial of gadolinium texaphyrin (Gd-Tex), a tumor selective radiation
sensitizer detectable by magnetic resonance imaging.
Clin Cancer Res.
1999;
5
739-745
- 38
Miller RA, Woodburn K, Fan Q, Renschler MF, Sessler JL, Koutcher JA.
In vivo animal studies with gadolinium(III) texaphyrin as a radiation enhancer. Int.
J Radiation Oncology Biol Phys.
1999;
45
981-989
Correspondence
H. HirschbergMD, PhD
Beckman Laser Institute
1002 Health Sciences Rd
Irvine
CA 92612
USA
Phone: +1/949/824 12 48
Email: hirschberg@laser.bli.uci.edu