Kardiologie up2date 2008; 4(2): 149-166
DOI: 10.1055/s-2007-995763
Herzrhythmusstörungen

© Georg Thieme Verlag KG Stuttgart · New York

Schrittmacheralgorithmen zur Minimierung der rechtsventrikulären Stimulation

Christof  Kolb, Stylianos  Tzeis, Bernhard  Zrenner
Further Information

Publication History

Publication Date:
06 June 2008 (online)

Abstract

Recent large, prospective, multi-centre trials have demonstrated detrimental effects of unnecessary right ventricular pacing. This review summarizes the results of the major trials and sheds light on the potential mechanisms that cause the unfavourable outcome. Different programming strategies to avoid unnecessary pacing in dual chamber pacemakers and implantable cardioverters defibrillators - especially in respect of every day clinical practise - are discussed.

Kernaussagen

  • Eine unnötige rechtsventrikuläre Stimulation bei (zumindest phasenweise) erhaltener intrinsischer atrioventrikulärer Überleitung führt zu einer frühzeitigen Batterieerschöpfung des Impulsgebers und erhöht die Morbidität des Vorhofflimmerns und der Herzinsuffizienz bei Schrittmacherpatienten; bei Patienten mit implantierten Defibrillatoren und eingeschränkter linksventrikulärer Funktion erhöht sie zusätzlich die Gesamtmortalität.

  • Es besteht für Schrittmacherpatienten eine lineare Korrelation zwischen ventrikulärem Stimulationsanteil und dem Risiko des Vorhofflimmerns für ventrikuläre Stimulationsanteile zwischen 0 und 80 % und eine lineare Korrelation zwischen ventrikulärem Stimulationsanteil und dem Herzinsuffizienzrisiko für ventrikuläre Stimulationsanteile zwischen 0 und 40 %. Reduktionen der ventrikulären Stimulationslast für höhere Stimulationsanteile haben keinen Einfluss auf die Patientenmorbidität.

  • Aufgrund der eindeutigen Datenlage besteht auch bei asymptomatischen Patienten die Indikation zur Umprogrammierung der Impulsgeber, um eine überwiegend eigene atrioventrikuläre Überleitung zu erzielen.

  • Der Schrittmacher sollte vorzugsweise im DDD(R)-Modus mit langer AV-Zeit und ggf. Anwendung der AV-Hysteresefunktion eingestellt werden. Alternativ können automatische Umschaltungen in den AAI(R)-Modus unter gleichzeitiger Überwachung der intrinsischen AV-Überleitung durch den Impulsgeber genutzt werden.

  • Um eine eigene atrioventrikuläre Überleitung zu erreichen, können PQ-Zeiten bis zu 270 ms akzeptiert werden.

  • Gelingt es im DDD(R)-Modus nicht, die AV-Zeit für eine eigene Überleitung zu optimieren, sollte geprüft werden, ob alternativ eine Stimulation vorzugsweise im AAI(R)-Modus klinisch vertretbar ist.

  • Unter optimierter Programmierung der Impulsgeber auf eine eigene atrioventrikuläre Überleitung können ungewöhnliche EKG-Konstellationen auftreten (z. B. Stimulation mit Frequenzen geringer als der programmierten Grundfrequenz oder fehlende getriggerte ventrikuläre Stimulation nach Vorhofdepolarisation bei automatischem Umschalten in den AAI(R)-Modus; inadäquate Vorhofarrhythmiedetektion durch Fernfeldsignale, „repetitive non-reentrant VA-synchrony”), deren Kenntnis und differenzialdignostische Abgrenzung für eine optimale Versorgung der Patienten bedeutsam ist.

  • Eine Optimierung der Schrittmacherprogrammierung auf eine intrinsische atrioventrikuläre Überleitung kommt nicht in Betracht für Patienten mit kardialer Resynchronisationstherapie oder hypertropher obstruktiver Kardiomyopathie.

Literatur

  • 1 Lascault G, Frank R, Iwa T. et al . Comparison of DDD and „VVI-R like” pacing during moderate exercise: echo-Doppler study.  Eur Heart J. 1992;  13 914-917
  • 2 Jutzy R V, Feenstra L, Pai R. et al . Comparison of intrinsic versus paced ventricular function.  Pacing Clin Electrophysiol. 1992;  11 1919-1922
  • 3 Ovsyshcher I, Zimlichman R, Katz A. et al . Measurements of cardiac output by impedance cardiography in pacemaker patients at rest: effects of various atrioventricular delays.  J Am Coll Cardiol. 1993;  21 761-767
  • 4 Brecker S J, Xiao H B, Sparrow J. et al . Effects of dual-chamber pacing with short atrioventricular delay in dilated cardiomyopathy.  Lancet. 1992;  340 1308-1312
  • 5 Hochleitner M, Hörtnagl H, Hörtnagl H. et al . Long-term efficacy of physiologic dual-chamber pacing in the treatment of end-stage idiopathic dilated cardiomyopathy.  Am J Cardiol. 1992;  70 1320-1325
  • 6 Andersen H R, Nielsen J C, Thomsen P E. et al . Long-term follow-up of patients from a randomised trial of atrial versus ventricular pacing for sick-sinus syndrome.  Lancet. 1997;  350 1210-1216
  • 7 Lamas G A, Lee K L, Sweeney M O. et al . Ventricular pacing or dual-chamber pacing for sinus-node dysfunction.  N Engl J Med. 2002;  346 1854-1862
  • 8 Stambler B S, Ellenbogen K A, Orav E J. et al . Investigators. Predictors and clinical impact of atrial fibrillation after pacemaker implantation in elderly patients treated with dual chamber versus ventricular pacing.  Pacing Clin Electrophysiol. 2003;  26 2000-2007
  • 9 Kerr C R, Connolly S J, Abdollah H. et al . Canadian Trial of Physiological Pacing: Effects of physiological pacing during long-term follow-up.  Circulation. 2004;  109 357-362
  • 10 Sweeney M O, Hellkamp A S, Ellenbogen K A. et al . Adverse effect of ventricular pacing on heart failure and atrial fibrillation among patients with normal baseline QRS duration in a clinical trial of pacemaker therapy for sinus node dysfunction.  Circulation. 2003;  107 2932-2937
  • 11 Sweeney M O, Bank A J, Nsah E. et al . Minimizing ventricular pacing to reduce atrial fibrillation in sinus-node disease.  N Engl J Med. 2007;  357 1000-1008
  • 12 Wilkoff B L, Cook J R, Epstein A E. et al . Dual-chamber pacing or ventricular backup pacing in patients with an implantable defibrillator: the Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial.  JAMA. 2002;  288 3115-3123
  • 13 Steinberg J S, Fischer A, Wang P. et al . The clinical implications of cumulative right ventricular pacing in the multicenter automatic defibrillator trial II.  J Cardiovasc Electrophysiol. 2005;  16 359-365
  • 14 Kolb C, Deisenhofer I, Schmieder S. et al . Long-term follow up of patients supplied with single chamber and dual chamber cardioverter defibrillators.  Pacing Clin Electrophysiol. 2006;  29 946-952
  • 15 Olshansky B, Day J D, Moore S. et al . Is dual-chamber programming inferior to single-chamber programming in an implantable cardioverter-defibrillator? Results of the INTRINSIC RV (Inhibition of Unnecessary RV Pacing With AVSH in ICDs) study.  Circulation. 2007;  115 9-16
  • 16 Kang S J, Song J K, Yang H S. et al . Systolic and diastolic regional myocardial motion of pacing-induced versus idiopathic left bundle branch block with and without left ventricular dysfunction.  Am J Cardiol. 2004;  93 1243-1246
  • 17 Nielsen J C, Kristensen L, Andersen H R. et al . A randomized comparison of atrial and dual-chamber pacing in 177 consecutive patients with sick sinus syndrome: echocardiographic and clinical outcome.  J Am Coll Cardiol. 2003;  42 614-623
  • 18 Rosenqvist M, Isaaz K, Botvinick E H. et al . Relative importance of activation sequence compared to atrioventricular synchrony in left ventricular function.  Am J Cardiol. 1991;  67 148-156
  • 19 Vanderheyden M, Goethals M, Anguera I. et al . Hemodynamic deterioration following radiofrequency ablation of the atrioventricular conduction system.  Pacing Clin Electrophysiol. 1997;  20 2422-2428
  • 20 Baldasseroni S, Opasich C, Gorini M. et al . Left bundle-branch block is associated with increased 1-year sudden and total mortality rate in 5517 outpatients with congestive heart failure: a report from the Italian network on congestive heart failure.  Am Heart J. 2002;  143 398-405
  • 21 Sweeney M O, Hellkamp A S, Lee K L. et al . Association of prolonged QRS duration with death in a clinical trial of pacemaker therapy for sinus node dysfunction.  Circulation. 2005;  111 2418-2423
  • 22 Nielsen J C, Bottcher M, Nielsen T T. et al . Regional myocardial blood flow in patients with sick sinus syndrome randomized to long-term single chamber atrial or dual chamber pacing - effect of pacing mode and rate.  J Am Coll Cardiol. 2000;  35 1453-1461
  • 23 Iliev I I, Yamachika S, Muta K. et al . Preserving normal ventricular activation versus atrioventricular delay optimization during pacing: the role of intrinsic atrioventricular conduction and pacing rate.  Pacing Clin Electrophysiol. 2000;  23 74-83
  • 24 Sutton R, Kenny R A. The natural history of sick sinus syndrome.  Pacing Clin Electrophysiol. 1986;  9 1110-1114
  • 25 Rosenqvist M, Obel I W. Atrial pacing and the risk for AV block: is there a time for change in attitude?.  Pacing Clin Electrophysiol. 1989;  12 97-101
  • 26 Lemke B, Nowak B, Pfeiffer D. et al . Leitlinien zur Herzschrittmachertherapie.  Z Kardiol. 2005;  94 704-720
  • 27 Eguía L E, Pinski S L, Haw J. et al . Which is the optimal testing method for identifying an AV delay that allows intrinsic conduction?.  Pacing Clin Electrophysiol. 2000;  23 1758-1761
  • 28 Maurer D E, Naegeli B, Straumann E. et al . Quality of life and exercise capacity in patients with prolonged PQ interval and dual chamber pacemakers: a randomized comparison of permanent ventricular stimulation versus intrinsic AV conduction.  Europace. 2003;  5 411-417
  • 29 Stierle U, Krüger D, Vincent A M. et al . An optimized AV delay algorithm for patients with intermittent atrioventricular conduction.  Pacing Clin Electrophysiol. 1998;  21 1035-1043
  • 30 Strohmer B, Pichler M, Froemmel M. et al . Evaluation of atrial conduction time at various sites of right atrial pacing and influence on atrioventricular delay optimization by surface electrocardiography.  Pacing Clin Electrophysiol. 2004;  27 468-474
  • 31 Dennis M J, Sparks P B. Pacemaker mediated tachycardia as a complication of the autointrinsic conduction search function.  Pacing Clin Electrophysiol. 2004;  27 824-826
  • 32 Nielsen J C, Pedersen A K, Mortensen P T. et al . Programming a fixed long atrioventricular delay is not effective in preventing ventricular pacing in patients with sick sinus syndrome.  Europace. 1999;  1 113-120
  • 33 Pioger G, Leny G, Nietzsché R. et al . AAIsafeR limits ventricular pacing in unselected patients.  Pacing Clin Electrophysiol. 2007;  30 S66-70 (Suppl. 1)
  • 34 Pürerfellner H, Brandt J, Israel C. et al . Comparison of two strategies to reduce ventricular pacing in pacemaker patients.  Pacing Clin Electrophysiol. 2008;  31 167-176

Dr. med. habil. Christof Kolb

Deutsches Herzzentrum München

Lazarettstr. 36

80636 München

Email: kolb@dhm.mhn.de

    >