CC BY-NC-ND-license · Joints 2016; 04(04): 236-246
DOI: 10.11138/jts/2016.4.4.236
Original Article
Georg Thieme Verlag KG Stuttgart · New York

Reverse total shoulder arthroplasty: research models

Stefano Petrillo
1   Department of Orthopaedic and Trauma Surgery, Campus Bio-Medico University, Trigoria, Rome, Italy
2   Centro Integrato di Ricerca (CIR) Campus Bio-Medico University, Trigoria, Rome, Italy
,
Umile Giuseppe Longo
1   Department of Orthopaedic and Trauma Surgery, Campus Bio-Medico University, Trigoria, Rome, Italy
2   Centro Integrato di Ricerca (CIR) Campus Bio-Medico University, Trigoria, Rome, Italy
,
Lawrence V. Gulotta
3   Sports Medicine and Shoulder Service, Hospital for Special Surgery, New York, USA
,
Alessandra Berton
1   Department of Orthopaedic and Trauma Surgery, Campus Bio-Medico University, Trigoria, Rome, Italy
2   Centro Integrato di Ricerca (CIR) Campus Bio-Medico University, Trigoria, Rome, Italy
,
Andreas Kontaxis
4   Leon Root, Motion Analysis Laboratory, New York, USA
,
Timothy Wright
3   Sports Medicine and Shoulder Service, Hospital for Special Surgery, New York, USA
,
Vincenzo Denaro
1   Department of Orthopaedic and Trauma Surgery, Campus Bio-Medico University, Trigoria, Rome, Italy
2   Centro Integrato di Ricerca (CIR) Campus Bio-Medico University, Trigoria, Rome, Italy
› Author Affiliations
Further Information

Publication History

Publication Date:
15 September 2017 (online)

Abstract

Purpose:the past decade has seen a considerable increase in the use of research models to study reverse total shoulder arthroplasty (RTSA). Nevertheless, none of these models has been shown to completely reflect real in vivo conditions.

Methods: we performed a systematic review of the literature matching the following key words: “reverse total shoulder arthroplasty” or “reverse total shoulder replacement” or “reverse total shoulder prosthesis” and “research models” or “biomechanical models” or “physical simulators” or “virtual simulators”. The following databases were screened: Medline, Google Scholar, EMBASE, CINAHIL and Ovid. We identified and included all articles reporting research models of any kind, such as physical or virtual simulators, in which RTSA and the glenohumeral joint were reproduced.

Results: computer models and cadaveric models are the most commonly used, and they were shown to be reliable in simulating in vivo conditions. Bone substitute models have been used in a few studies.

Mechanical testing machines provided useful information on stability factors in RTSA.

Conclusions: because of the limitations of each individual model, additional research is required to develop a research model of RTSA that may reduce the limitations of those presently available, and increase the reproducibility of this technique in the clinical setting.