Vet Comp Orthop Traumatol 2008; 21(01): 69-75
DOI: 10.3415/VCOT-06-10-0080
Clinical Communication
Schattauer GmbH

Use of T-plates for the stabilisation of supracotyloid ilial fractures in 18 cats and five dogs

J.-C. Troger
1   Surgical Referral Free-land practice, Sceaux, France
,
E. Viguier
2   Department of Surgery and Anesthesiology, Ecole Vétérinaire de Lyon, Marcy l'Etoile, France
› Author Affiliations
Further Information

Publication History

Received 16 October 2006

Accepted 05 February 2007

Publication Date:
17 December 2017 (online)

Summary

The use of the AO (Arbeitgemeinschaft fur Osteosynthe- senfragen) veterinary T-plates (1.5/2 mm and 2.7/3.5 mm) forstabilisation ofsupracotyloid ilial fractures in 18 cats and five dogs was evaluated in a retrospective study. The distal fragment from the coxofemoral joint ranged from 0.5 cm to 1 cm with a mean distance of 0.85 cm. Twenty out of 23 (87%) ilial fractures healed in original alignment. Three out of 23 (13%) animals had two loosened screws of the distal fragment with fracture malunion and minor medial displacement of the acetabular fragment. Screw or plate breakage was not observed and the implants were not removed. The clinical result was ‘excellent’ for 18 animals (78%), ‘good’ for four animals (17%), and ‘poor’ for one animal (5%). The use of T-plates permits good correction ofsupracotyloid fractureswith minimal approach and minimizes post-operative complications.

 
  • References

  • 1 Breshears LA, Fitch RB, Wallace LJ. et al. The radiographic evaluation of repaired canine ilial fractures (69 cases). Vet Comp Orthop Traumatol 2004; 17: 64-72.
  • 2 Brinker W. Fractures of the Pelvis. In: Brinker WO, Piermattei DL, Flo GL. Handbook of Small Animal Orthopaedics and Fracture Repair. et al. Philadelphia: W.B. Saunders; 1997
  • 3 DeCamp CE. Principles of Pelvic Fracture Management. Semin Vet Med Surg (Small Anim) 1992; 7: 63-70.
  • 4 Henry W. A method of bone plating for iliac and acetabular fractures. Comp of Cont Educ PractVet 1985; 7: 924-938.
  • 5 Tomlinson JL. Fractures of the Pelvis. In Slatter D. ed. Textbook of Small Animal Surgery. et al. Philadelphia: WB. Saunders; 2003: 1989-2001.
  • 6 Denny H. Pelvic fractures in the dog: a review of 123 cases. J Small Animal Pract 1978; 19: 151-166.
  • 7 Hulse D, VanGundy T, Johnson S. et al. Compression screw stabilization of oblique ilial fractures. Vet Comp Orthop Traumatol 1989; 4: 162-167.
  • 8 Van Gundy T. Fixation of iliac fractures: lag screw fixation. Veterinary Medicine Report 1990; 2: 303-309.
  • 9 Van Gundy T, Hulse D, Nelson J. et al. Mechanical evaluation of two canine iliac fracture fixation systems. VetSurg 1988; 17: 321-327.
  • 10 Ost PO, Kaderly RE. Use of reconstruction plates for the repair of segmental ilial fractures involving acetabular comminution in four dogs. Vet Surg 1986; 15: 259-264.
  • 11 Richardson D. Fixation of iliac fractures: plate fixation. Veterinary Medicine Report 1990; 2: 302-307.
  • 12 Piermattei DL. Approach to the ilium. In: Piermattei DL. An Atlas of Surgical approaches to the Bones and Joints of the Dog and Cat. et al. Philadelphia: Saunders; 1993
  • 13 Hamilton MH, Langley Hobbs SJ. Use of the AO veterinary mini-T-plate for stabilisation of distal radius and ulnar fractures in toy breed dogs. Vet Comp Orthop Traumatol 2005; 18: 18-25.
  • 14 Von Pfeil DJF, Roush JK. The use of stacked T-plating in dogs. Vet Comp Orthop Traumatol 2003; 16: 260-265.
  • 15 Thomson MJ, Read RA, Day R. The comparative strengths of orthopaedic staples versus a 2,7 T Plate in the stabilisation of distal radial osteotomies. Vet Comp Orthop Traumatol 1998; 11: 100-4.
  • 16 Wallace MK, Boudrieau RJ, Hyodo K. et al. Mechanical evaluation of three methods of plating distal radial osteotomies. Vet Surg 1992; 21: 99-106.
  • 17 Balfour RJ. T-plate fixation of distal radial closing wedge osteotomies for treatment of angular limb deformities in 18 dogs. Vet Surg 2000; 29: 207-217.
  • 18 Schatzker J. manual of Internal Fixation: Techniques recommended by the AO-ASIF Group. et al. Berlin. NewYork: Springer-Verlag; 1991
  • 19 Roush J, Manley P. Mini plate failure after repair of ilial and acetabular fractures in nine small dogs and one cat. J Am Anim Hosp Assoc 1992; 28: 112-118.
  • 20 Lanz OI, Lewis DD, Madison JB. et al. A biomech- anical comparison of composite fixation and Veterinary Acetabular Plates of Acetabular Osteotomies in Dogs Loaded in Three-point-bending fashion. Vet Comp Orthop Traumatol 1998; 11: 152-157.
  • 21 Lewis DD, Stubbs WP, Neuwirth L. Results of Screw/Wire/Polymethylmethacrylate Composite Fixation for Acetabular Fracture Repair in 14 dogs. Vet Surg 1997; 26: 223-234.
  • 22 Anson LW, De Young DJ, Richardson DC. et al. Clinical evaluation of canine acetabular fractures stabilized with an acetabular plate. Vet Surg 1988; 17: 220-225.