Open Access
CC BY-NC 4.0 · Arch Plast Surg 2017; 44(01): 42-47
DOI: 10.5999/aps.2017.44.1.42
Original Article

Safe and Simplified Salvage Technique for Exposed Implantable Cardiac Electronic Devices under Local Anesthesia

Chang Young Jung
Department of Plastic and Reconstructive Surgery, Yeungnam University College of Medicine, Daegu, Korea
,
Department of Plastic and Reconstructive Surgery, Yeungnam University College of Medicine, Daegu, Korea
,
Sung-Eun Kim
Department of Plastic and Reconstructive Surgery, Yeungnam University College of Medicine, Daegu, Korea
,
Department of Plastic and Reconstructive Surgery, Yeungnam University College of Medicine, Daegu, Korea
,
Department of Plastic and Reconstructive Surgery, Yeungnam University College of Medicine, Daegu, Korea
,
Department of Plastic and Reconstructive Surgery, Yeungnam University College of Medicine, Daegu, Korea
› Author Affiliations
Preview

Background Skin erosion is a dire complication of implantable cardiac pacemakers and defibrillators. Classical treatments involve removal of the entire generator and lead systems, however, these may result in fatal complications. In this study, we present our experience with a simplified salvage technique for exposed implantable cardiac electronic devices (ICEDs) without removing the implanted device, in an attempt to reduce the risks and complication rates associated with this condition.

Methods The records of 10 patients who experienced direct ICED exposure between January 2012 and December 2015 were retrospectively reviewed. The following surgical procedure was performed in all patients: removal of skin erosion and capsule, creation of a new pocket at least 1.0–1.5 cm inferior to its original position, migration of the ICED to the new pocket, and insertion of closed-suction drainage. Patients with gross local sepsis or septicemia were excluded from this study.

Results Seven patients had cardiac pacemakers and the other 3 had implantable cardiac defibrillators. The time from primary ICED placement to exposure ranged from 0.3 to 151 months (mean, 29 months. Postoperative follow-up in this series ranged from 8 to 31 months (mean follow-up, 22 months). Among the 10 patients, none presented with any signs of overt infection or cutaneous lesions, except 1 patient with hematoma on postoperative day 5. The hematoma was successfully treated by surgical removal and repositioning of the closed-suction drainage.

Conclusions Based on our experience, salvage of exposed ICEDs is possible without removing the device in selected patients.

This work was supported by the 2013 Yeungnam University Research Grant. This article was presented at the Third Research and Reconstructive Forum on May 9–10, 2013 in Daegu, Korea.




Publication History

Received: 11 July 2016

Accepted: 20 October 2016

Article published online:
20 April 2022

© 2017. The Korean Society of Plastic and Reconstructive Surgeons. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonCommercial License, permitting unrestricted noncommercial use, distribution, and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes. (https://creativecommons.org/licenses/by-nc/4.0/)

Thieme Medical Publishers, Inc.
333 Seventh Avenue, 18th Floor, New York, NY 10001, USA