Introduction
Pancreatic cancer is the fourth leading cause of cancer-related death in Western countries
with an overall 5-year survival rate of 5 % to 6 % and a median survival of 3 to 5
months after diagnosis of metastatic disease. Accurate diagnosis of pancreatic lesions
is crucial to ensure that proper treatment is provided and the optimum prognosis achieved
[1]
[2]
[3]
[4].
Diagnosis of pancreatic lesions was significantly improved with application of endoscopic
ultrasound (EUS). EUS-guided fine-needle aspiration (FNA) has been the mainstay for
tissue acquisition for evaluation of pancreatic lesions since 1990s, with sensitivity
varying from 88 % to 100 % and specificity of up to 100 % [5]
[6]
[7]
[8]
[9]. Despite the success of EUS-FNA, the diagnostic sampling technique has several limitations.
The most important limitation of FNA is that cytology specimens may be of limited
value in certain disease entities for which diagnosis relies on tissue architecture
or ancillary studies [3]
[4]
[5]. For example, cytological analysis alone may not distinguish inflammation from well-differentiated
neoplasia because inflammation results in a reactive and regenerative process leading
to cellular changes. In addition, certain conditions, such as lymphoma, neuroendocrine
tumors, autoimmune pancreatitis, and stromal tumors, require histological specimens
with preserved architecture, necessitating immunohistochemical (IHC) staining and
histologic diagnosis [10]
[11]
[12]
[13]. Furthermore, EUS-FNA often requires multiple passes to obtain adequate tissue and
rapid on-site evaluation (ROSE) for optimal yield, although it remains unclear to
what extent ROSE impacts diagnostic accuracy [7]
[14]
[15].
To overcome limitations associated with EUS-FNA cytology and improve diagnostic accuracy,
a 19G trucut needle biopsy (EUS-TNB) was designed to procure larger amounts of tissue
with conserved architecture, thus enabling histological analysis. Although EUS-TNB
has shown greater diagnostic accuracy compared with EUS-FNA for submucosal lesions
and lymphoma, and potentially required fewer needle passes for solid pancreatic neoplasms,
this first generation fine-needle biopsy (FNB) device failed to demonstrate superiority
over traditional FNA. Moreover, the technical failure rate was high, especially when
TNB was attempted with an angulated scope position such as a transduodenal approach
due to the stiffness of the device [16]
[17]. Consequently, more flexible second-generation core biopsy needles have been developed,
and are being increasingly utilized for tissue acquisition – providing not just cytological
aspirates but also histologic core samples.
These include reverse bevel needles, side-open needles, and fork-tip needles to collect
core sample. These needles are available in several sizes including 19G, 20G, 21G,
22G, and 25G needles and enable approaches such as a transduodenal approach, which
is important for lesions in the head and uncinate process of the pancreas [3]
[4]
[5]
[7]. Core tissue samples obtained with these newer FNB needles may improve diagnostic
yield and obviate the need for ROSE; however, data is limited. A previous meta-analysis
reported that EUS-FNB is a reliable diagnostic tool for solid pancreatic masses with
sensitivity and specificity of 84 % and 98 %, respectively [18]; however, high-quality studies comparing these second generation FNB needles with
standard FNA needles have reached different conclusions [2]
[5].
We therefore conducted this large multicenter study, to compare diagnostic yield and
safety between EUS-FNA and EUS-FNB in sampling of pancreatic masses.
Patients and methods
Material and methods
This was a multi-center, retrospective study conducted at five hospitals in Massachusetts,
United States (Brigham and Women’s Hospital, Massachusetts General Hospital, Brigham
and Women’s Faulkner Hospital, Newton-Wellesley Hospital, and North Shore Medical
Center) following the STAndards for the Reporting of Diagnostic accuracy studies (STARD) recommendations (Appendix 1). The study was approved by the Institutional Review Board from Partners Healthcare.
All consecutive patients, age ≥ 18 years, that had undergone EUS-guided tissue acquisition
of pancreatic masses from January 2016 to January 2019 were identified from a shared
prospective registered. Search terms included: endoscopic ultrasound and pancreatic
mass or pancreatic lesion and fine needle aspiration or fine needle biopsy. This database
contains information on patient demographics (i. e., sex, age, and comorbidities),
lesion characteristics (i. e., location, size, heterogeneity, and echogenicity), and
procedure details (i. e., route of tissue sampling, size and type of the needle, number
of passes, diagnostic adequacy of cytological specimen on rapid on-site evaluation
(ROSE) when it was available, and diagnostic adequacy on cell block and on slides
examination). Additionally, the database contains information regarding patient follow-up,
including adverse events (AEs), other diagnostic methods if performed, oncological
treatment, and surgery.
Procedural technique
All EUS-guided tissue sampling procedures were performed with a linear array echoendoscope
(Olympus GF-UCT180, Olympus, Center Valley, Pennsylvania, United States) under monitored
anesthesia care by experienced endosonographers or by fellows under expert supervision.
Several different needles were used during these period, including 19G, 22G, and 25G
FNA needles (Expect, Boston Scientific Corporation, Natick, MA, USA or Echotip, Wilson-Cook
Medical, Winston-Salem, North Carolina, United States or Beacon, Medtronic Corporation,
Newton, Massachusetts, United States) and 19G, 20G, 21G, 22G, and 25G FNB needles
(Acquire, Boston Scientific Corporation, Natick, Massachusetts, United States or SharkCore,
Medtronic Corporation, Newton, Massachusetts, United States or ProCore, Cook Medical,
Winston-Salem, North Carolina, United States). After the lesion was identified and
punctured under EUS guidance, a general fanning technique was performed. Individual
operator technique varied from each center, including stylet slow-pull technique and
standard suction.
Rapid on-site evaluations (ROSE)
ROSE, which may be used to check sample adequacy and establish a preliminary diagnosis
using a rapid stain, was not available in all cases. In cases where ROSE was performed,
FNA specimens were expressed onto slides and then smeared for onsite preparation.
FNB specimens were prepared using the touch imprint technique. To accomplish this
technique, the tissue surface was slighted pressed onto the slides prior to staining
to reduce the creation of crushing artifacts. All slides were prepared using both
wet-fixed (placed in 96 % ethyl alcohol for Papanicolaou staining) and air-dried (in
some cases stained with Diff-Quik) techniques.
FNA evaluation
The samples obtained through EUS-FNA were transferred to three to 12 slides. Each
smear was made with slight pressure to avoid crushing artifacts with half of the slides
then placed immediately in the 96 % ethyl alcohol solution and the others fixed in
the air. When possible, part of the material was placed in formalin solution for the
preparation of the cell-block. The specimen was subsequently sent to the pathology
division, for processing and staining by Papanicolaou method (i. e., slides in alcohol
solution), Diff-Quick Staining Protocol (i. e., air-dried slides), and hematoxylin
and eosin stain (i. e., cell-block). After these processes, the cytological material
was examined by experienced cytopathologists. IHC analysis was performed in selected
cases when needed.
FNB evaluation
FNB samples were fixed in buffered formalin (10 % formalin) and dehydrated before
being embedded in paraffin. The tissue was subsequently sliced into a 4-μm to 6-μm
sections and stained with hematoxylin-eosin. In addition, in some cases, FNB specimens
were prepared in slides using the touch imprint technique. The analyzes were performed
by experienced pathologists. IHC analysis was performed in selected cases when needed.
Outcome measures
The primary outcome was the diagnostic yield [i. e., sensitivity, specificity, positive
likelihood ratio (LR+), negative likelihood ratio (LR–), positive predictive value
(PPV), negative predictive value (NPV), and accuracy] of EUS-FNA and EUS-FNB from
cytologic or histologic analysis with and without IHC staining. Inconclusive specimen
results were considered as non-neoplastic lesions as to not overestimate diagnostic
yield. Secondary outcomes included the proportion of adequate cellularity for ROSE
evaluation, median number of needle passes, diagnostic result from histologic (cell-block)
and cytologic (slides) analysis, as well as AEs related to the procedure. Surgical
resection pathology was considered the gold standard for comparison to determine diagnostic
accuracy. However, because most patients did not undergo surgery due to benign findings
or poor surgical candidacy, patient follow-up for at least 6 months was also considered
as the reference standard.
Statistical analysis
Baseline patient characteristics and procedure characteristics were summarized as
means ± standard deviation for continuous data and frequencies and proportions for
categorical data. As diagnostic tests were performed on two independent groups of
patients, a bivariate model was used to compute the pooled sensitivity and specificity,
and diagnostic accuracy. Two-sample t-tests for binomial proportions were used [19]. Continuous data were compared using the two-sample t-test or Wilcoxon rank-sum test and categorical data were compared using the Chi-square
or Fisher’s exact test as appropriate [20]. Statistical significance was defined as a P < 0.05.
Subgroup analyses to compare diagnostic yield were performed based upon route of sampling.
Additional analyses were also performed to identify the diagnostic yield of FNA alone,
FNA with ROSE, FNB alone, and FNB with ROSE. From this data, sensitivity, specificity,
PPV, NPV, +LR, –LR, and accuracy were compared to determine if ROSE was beneficial.
In effort to identify factors associated with diagnostic performance between FNA and
FNB needle types, a multivariable logistic regression was performed with adjustment
for clinically significant univariate findings as well as age, gender, needle type,
needle size, and application of ROSE and cell block on. Results of the regression
analysis were expressed as beta-coefficient (β) and odds ratio (OR). Statistical analyses
were performed using the Stata 13.0 software package (Stata Corp LP, College Station,
TX).
Results
Baseline patient and lesion characteristics
A total of 574 patients (308 male and 266 female) with a mean age of 60.85 ± 12.81
years old were enrolled in this study between January 2016 to January 2019. No significant
difference was noted between FNA and FNB cohorts. Technical success was 100 %. Of
the 574 patients, 194 underwent FNA and 380 FNB. Most of the lesions were located
at the head of the pancreas (n = 248), followed by body (n = 141), tail (n = 109),
uncinate (n = 42), and neck (n = 34). The most common route of sampling was via a
transduodenal approach (49.45 %) followed by transgastric (48.91 %), with the remaining
procedures requiring both transduodenal and transgastric approaches (1.64 %). Mean
size of all lesions was 28.56 ± 13.38 mm with no difference in sizes between FNA and
FNB (27.02 ± 14.05 mm versus 29.29 ± 13.01; P = 0.066). Complete baseline characteristics for all included patients as well as
stratification by FNA or FNB cohort are demonstrated in [Table 1].
Table 1
Baseline patient characteristics, lesion details, and sampling characteristics.
Results
|
Total
|
FNA
|
FNB
|
P value
|
Patient characteristics
|
No. of patients
|
574
|
194
|
380
|
|
Age (years)
|
66.69 (11.76)
|
66.28 (10.75)
|
66.90 (12.26)
|
0.633
|
Gender
|
0.296
|
No. of males (%)
|
308 (53.66 %)
|
110 (56.70 %)
|
198 (52.11 %)
|
|
No. of females (%)
|
266 (46.34 %)
|
84 (43.30 %)
|
182 (47.89 %)
|
|
Pancreatic lesion site
|
0.819
|
Head
|
248
|
85 (43.81 %)
|
162 (42.89 %)
|
|
Neck
|
34
|
9 (4.64 %)
|
25 (6.58 %)
|
|
Body
|
141
|
45 (23.20 %)
|
96 (25.26 %)
|
|
Tail
|
109
|
40 (20.62 %)
|
69 (18.16 %)
|
|
Uncinate
|
42
|
15 (7.73 %)
|
27 (7.11 %)
|
|
Lesion size
|
28.56 (13.38)
|
27.02 (14.05)
|
29.29 (13.01)
|
0.066
|
Diagnostic sample approach
|
0.097
|
Transgastric
|
269 (48.91 %)
|
88 (48.35 %)
|
181 (49.18 %)
|
|
Tranduodenal
|
272 (49.45 %)
|
88 (48.35 %)
|
184 (50.00 %)
|
|
Both transgastric and transduodenal
|
9 (1.64 %)
|
6 (3.30 %)
|
3 (0.82 %)
|
|
Needle size
|
< 0.001
|
20 g
|
4 (0.70 %)
|
0 (0.00 %)
|
4 (1.06 %)
|
|
21 g
|
4 (0.70 %)
|
0 (0.00 %)
|
4 (1.06 %)
|
|
22 g
|
302 (52.89 %)
|
66 (34.20 %)
|
236 (62.43 %)
|
|
25 g
|
261 (45.71 %)
|
127 (65.80 %)
|
134 (35.45 %)
|
|
No of passes
|
3.05 (1.71)
|
3.04 (1.88)
|
3.06 (1.62)
|
0.11
|
No. of samples with ROSE
|
< 0.001
|
Yes
|
251 (43.88 %)
|
122 (62.89 %)
|
129 (34.13 %)
|
|
No
|
321 (56.12 %)
|
72 (37.11 %)
|
249 (65.87 %)
|
|
Adequate sample for ROSE
|
0.914
|
Yes
|
237 (94.42 %)
|
115 (94.26 %)
|
122 (94.57 %)
|
|
No
|
14 (5.38 %)
|
7 (5.74 %)
|
7 (5.43 %
|
|
No. of passes for ROSE adequacy
|
3.32 (1.82)
|
3.17 (1.80)
|
3.46 (1.84)
|
0.211
|
No. of samples with cell block
|
< 0.001
|
Yes
|
511 (89.02 %)
|
156 (80.41 %)
|
355 (93.42 %)
|
|
No
|
63 (10.98 %)
|
38 (19.59 %)
|
25 (6.58 %)
|
|
No. of passes for cell block diagnosis
|
3.21 (± 1.87)
|
3.35 (2.02)
|
3.08 (1.63)
|
0.137
|
ROSE, rapid on-site evaluation
Needle and sampling characteristics
Multiple needle sizes were used in this study, including, 20G, 21G, 22G, and 25G.
The latter two were more commonly utilized (52.89 % and 45.71 %, respectively). There
was a significant difference in needle size between FNA and FNB cohorts (P < 0.001) with FNA relying primarily upon 25G and FNB with 22G needle. There was no
significant difference in number of passes between lesions sampled with FNA and FNB
(3.04 ± 1.88 versus 3.06 ± 1.62; P = 0.110). The majority of patients did not have ROSE performed (56.12 %). ROSE was
more commonly performed among FNA samples compared to FNB (62.89 % versus 34.13 %;
P < 0.001). Among patients having ROSE, sample adequacy for ROSE as well as number
of passes was not significantly different [(FNA 94.26 % versus FNB 94.57 %, P = 0.914) and (FNA 3.17 ± 1.80 versus FNB 3.46 ± 1.84; P = 0.211), respectively]. Cell-block analysis was more common among FNB lesions (93.42 %
versus 80.41 %; P < 0.001) with a comparable number of passes required to achieve a conclusive diagnosis
(FNA 3.33 ± 2.02 versus 3.08 ± 1.63, P = 0.137). Further sampling characteristics are illustrated in [Table 1].
Comparison of diagnostic characteristics
Overall sensitivity, specificity, and accuracy of FNA and FNB for pancreatic lesions
was 87.96 % (95 % CI, 84.74 to 90.71), 97.59 % (95 % CI, 91.57 to 99.71), and 89.35 %
(95 % CI, 86.54 to 91.76). Compared to FNA, FNB resulted in comparable sensitivity
[85.62 % (95 % CI, 79.22 to 90.66) versus 89.09 % (95 % CI, 85.22 to 92.24); P = 0.229] and similar specificity [96.88 % (95 % CI, 83.78 to 99.92) versus 98.04 % (95 %
CI, 89.55 to 99.95); P = 0.387]. Accuracy was not different for FNA as compared to FNB [87.50 % (95 % CI, 81.97
to 91.82) versus 90.29 % (95 % CI, 86.86 to 93.07), P = 0.307]. PPV and NPV were also similar for FNA versus FNB [(99.28 % (95 % CI, 95.21
to 99.89) versus 99.66 % (95 % CI, 97.69 to 99.95), P = 0.529)] and [(57.41 % (95 % CI, 47.88 to 66.41) versus 58.14 % (95 % CI, 50.44
to 65.46), P = 0.867], respectively]. One patient with underlying pancreatitis and a suspected
neuroendocrine tumor underwent EUS-FNB and her clinical condition worsened after the
procedure. This patient died 5 days after tissue sampling due to worsening pancreatitis.
Complete diagnostic test characteristics are shown in [Table 2].
Table 2
Summary of results.
Diagnostic test characteristics
|
Total
|
FNA
|
FNB
|
P value
|
Sensitivity
|
87.96 % (95 % CI, 84.74 to 90.71)
|
85.62 % (95 % CI, 79.22 to 90.66)
|
89.09 % (95 % CI, 85.22 to 92.24)
|
0.229
|
Specificity
|
97.59 % (95 % CI, 91.57 to 99.71)
|
96.88 % (95 % CI, 83.78 to 99.92)
|
98.04 % (95 % CI, 89.55 to 99.95)
|
0.387
|
Positive likelihood ratio
|
36.50 (95 % CI, 9.28 to 143.58)
|
27.40 (95 % CI, 3.98 to 188.81)
|
45.44 (95 % CI, 6.52 to 316.51)
|
0.714
|
Negative likelihood ratio
|
0.12 (95 % CI, 0.10 to 0.16)
|
0.15 (95 % CI, 0.10 to 0.22)
|
0.11 (95 % CI, 0.08 to 0.15)
|
0.253
|
Positive predictive value
|
99.54 % (95 % CI, 98.21 to 99.88)
|
99.28 % (95 % CI, 95.21 to 99.89)
|
99.66 % (95 % CI, 97.69 to 99.95)
|
0.529
|
Negative predictive value
|
57.86 % (95 % CI, 51.88 to 63.61)
|
57.41 % (95 % CI, 47.88 to 66.41)
|
58.14 % (95 % CI, 50.44 to 65.46)
|
0.867
|
Accuracy
|
89.35 % (95 % CI, 86.54 to 91.76)
|
87.50 % (95 % CI, 81.97 to 91.82)
|
90.29 % (95 % CI, 86.86 to 93.07)
|
0.307
|
Serious adverse events
|
1 (0.17)
|
0 (0.00)
|
1 (0.26)
|
0.821
|
FNA, fine-needle aspiration; FNB, fine-needle biopsy
Subgroup analyses
A subgroup analysis was also performed for lesion with subsequent surgical resection
to confirm the diagnosis. A total of 156 patients (FNA: n = 56 vs FNB: n = 100) had
confirmatory pathology via autopsy or surgical pathology. There was no difference
in sensitivity [FNA: 87.27 % (95 % CI, 75.52 to 94.73) versus FNB: 85.71 % (95 % CI,
77.19 to 91.96), P = 0.785] though FNB was associated with a higher specificity [FNA: 0.00 % (95 % CI,
0.00 to 97.50) versus FNB: 100.00 % (95 % CI, 15.81 to 100.00 %); P < 0.001]. There was no difference in diagnostic accuracy between FNA versus FNB for
patients with confirmed surgical pathology [FNA: 85.71 % (95 % CI, 73.78 to 93.62)
versus FNB: 86.00 % (95 % CI, 77.63 to 92.13 %); P = 0.960].
Comparison based on EUS-tissue sampling
A comparison between FNA and FNB based on EUS-tissue sampling access was also performed.
This analysis showed no difference in accuracy between needles based on transgastric
or transduodenal approaches (P > 0.05). The results of the subgroup analysis are shown in [Table 3].
Table 3
Comparison between FNA and FNB based on EUS-tissue sampling access.
Transgastric access
|
Total
|
FNA
|
FNB
|
P value
|
Sensitivity
|
85.40 % (95 % CI, 80.11 to 89.73)
|
84.29 % (95 % CI, 73.62 to 91.89)
|
87.01 % (95 % CI, 80.66 to 91.88)
|
0.546
|
Specificity
|
97.78 % (95 % CI, 88.23 to 99.94)
|
100.00 % (95 % CI, 81.47 to 100.00)
|
96.30 % (95 % CI, 81.03 to 99.91)
|
0.977
|
Positive likelihood ratio
|
38.43 (95 % CI, 5.53 to 267.11)
|
NA
|
23.49 (95 % CI, 3.43 to 160.94)
|
NA
|
Negative likelihood ratio
|
0.15 (95 % CI, 0.11 to 0.21)
|
0.16 (95 % CI, 0.09 to 0.27)
|
0.13 (95 % CI, 0.09 to 0.20)
|
0.951
|
Positive predictive value
|
99.48 % (95 % CI, 96.52 to 99.93)
|
100.00 %
|
99.26 % (95 % CI, 95.14 to 99.89)
|
0.419
|
Negative predictive value
|
57.14 % (95 % CI, 49.23 to 64.70)
|
62.07 % (95 % CI, 48.75 to 73.79)
|
56.52 % (95 % CI, 46.18 to 66.33)
|
0.387
|
Accuracy
|
87.45 % (95 % CI, 82.91 to 91.15)
|
87.50 % (95 % CI, 78.73 to 93.59)
|
88.40 % (95 % CI, 82.81 to 92.67)
|
0.831
|
Transduodenal access
|
Sensitivity
|
89.12 % (95 % CI, 84.471 to 92.77)
|
85.71 % (95 % CI, 75.87 to 92.65)
|
90.74 % (95 % CI, 85.19 to 94.72)
|
0.214
|
Specificity
|
96.97 % (95 % CI, 84.24 to 99.92)
|
90.91 % (95 % CI, 58.72 to 99.77)
|
100.00 % (95 % CI, 84.56 to 100.00)
|
0.943
|
Positive likelihood ratio
|
29.41 (95 % CI, 4.27 to 202.74)
|
9.43 (95 % CI, 1.45 to 61.24)
|
NA
|
NA
|
Negative likelihood ratio
|
0.11 (95 % CI, 0.08 to 0.16)
|
0.16 (95 % CI, 0.09 to 0.28)
|
0.09 (95 % CI, 0.106 to 0.15)
|
0.482
|
Positive predictive value
|
99.53 % (95 % CI, 96.87 to 99.93)
|
98.51 % (95 % CI, 91.04 to 99.77)
|
100.00 %
|
0.991
|
Negative predictive value
|
55.17 % (95 % CI, 46.00 to 64.00)
|
47.62 % (95 % CI, 33.77 to 61.84)
|
59.46 % (95 % CI, 47.53 to 70.37)
|
0.902
|
Accuracy
|
90.07 % (95 % CI, 85.89 to 93.36)
|
86.36 % (95 % CI, 77.39 to 92.75)
|
91.85 % (95 % CI, 86.91 to 95.37)
|
0.157
|
FNA, fine-needle aspiration; FNB, fine-needle biopsy; EUS, endoscopic ultrasound
Diagnostic yield with and without ROSE
A comparison between methods with and without ROSE was also performed. Overall, FNB
with ROSE presented the higher sensitivity, specificity, and accuracy compared to
other variables. FNA with ROSE was superior to FNA alone regarding sensitivity and
accuracy [91.96 % (95 % CI, 85.29 to 96.26) and 91.80 % (95 % CI, 85.44 to 96.00)
versus 70.83 % (95 % CI, 55.94 to 83.05) and 80.28 % (95 % CI, 69.14 to 88.78); P < 0.05]. Regarding sensitivity, both FNB and FNB with ROSE were superior to FNA alone
[87.44 % (95 % CI, 82.26 to 91.56), 92.17 % (95 % CI, 85.66 to 96.36) versus 70.83 %
(95 % CI, 55.94 to 83.05); P < 0.05)]. FNB with ROSE presented higher accuracy than FNB alone [93.13 (95 % CI,
87.36 to 96.81) versus 80.72 (95 % CI, 84.16 to 92.40); P = 0.001]. There was no difference in sensitivity though improved accuracy between
FNA with ROSE versus FNB alone [(91.96 % versus 87.44 %; P = 0.193) and (91.80 % versus 80.72 %; P = 0.006)] ([Table 4] and [Table 5]).
Table 4
Comparison between methods with and without ROSE.
Results
|
FNA alone
|
FNA with ROSE
|
FNB alone
|
FNB with ROSE
|
Sensitivity
|
70.83 % (95 % CI, 55.94 to 83.05)
|
91.96 % (95 % CI, 85.29 to 96.26)
|
87.44 % (95 % CI, 82.26 to 91.56)
|
92.17 % (95 % CI, 85.66 to 96.36)
|
Specificity
|
100.00 % (95 % CI, 85.18 to 100)
|
90.00 % (95 % CI, 55.50 to 99.75)
|
97.06 % (95 % CI, 84.67 to 99.93)
|
100.00 % (95 % CI, 79.41 to 100.00)
|
Positive Likelihood Ratio
|
NA
|
9.20 (95 % CI, 1.43 to 59.09)
|
29.73 (95 % CI, 4.31 to 205.16)
|
NA
|
Negative Likelihood Ratio
|
0.29 (95 % CI, 0.19 to 0.45)
|
0.09 (95 % CI, 0.05 to 0.17)
|
0.13 (95 % CI, 0.09 to 0.18)
|
0.08 (95 % CI, 0.04 to 0.15)
|
Positive Predictive Value
|
100.00 %
|
99.04 % (95 % CI, 94.13 to 99.85)
|
99.47 % (95 % CI, 96.46 to 99.92)
|
100.00 %
|
Negative Predictive Value
|
62.16 % (95 % CI, 51.39 to 71.86)
|
50.00 % (95 % CI, 34.08 to 65.92)
|
55.00 % (95 % CI, 46.09 to 63.60)
|
64.00 % (95 % CI, 48.780 to 76.90)
|
Accuracy
|
80.28 % (95 % CI, 69.14 to 88.78)
|
91.80 % (95 % CI, 85.44 to 96.00)
|
80.72 % (95 % CI, 84.16 to 92.40)
|
93.13 % (95 % CI, 87.36 to 96.81)
|
FNA, fine-needle aspiration; FNB, fine-needle biopsy; ROSE, rapid one-site evaluation
Table 5
Statistical analyses between methods with and without ROSE.
|
FNA vs FNA + ROSE (Pvalue)
|
FNA vs FNB (Pvalue)
|
FNA vs FNB + ROSE (Pvalue)
|
FNA + ROSE vs FNB (Pvalue)
|
FNA + ROSE vs FNB + ROSE
(P value)
|
FNB vs FNB + ROSE (Pvalue)
|
Sensitivity
|
< 0.001
|
< 0.001
|
< 0.001
|
0.193
|
0.951
|
0.161
|
Specificity
|
0.006
|
0.145
|
NA
|
0.004
|
< 0.001
|
0.048
|
Positive Likelihood Ratio
|
NA
|
NA
|
NA
|
< 0.001
|
NA
|
NA
|
Negative Likelihood Ratio
|
0.741
|
0.770
|
0.717
|
0.916
|
0.978
|
0.890
|
Positive Predictive Value
|
0.409
|
0.547
|
NA
|
0.634
|
0.262
|
0.405
|
Negative Predictive Value
|
0.103
|
0.284
|
0.796
|
0.365
|
0.025
|
0.091
|
Accuracy
|
0.020
|
0.934
|
0.006
|
0.006
|
0.689
|
0.001
|
FNA, fine-need aspiration; ROSE, rapid on-site evaluation; FNB, fine-needle biopsy
Multivariate logistic regression
Multivariate analysis was then performed controlling for age, gender, needle type,
needle size, use of ROSE, and cell block assessment on diagnostic accuracy. Based
upon the results of this multivariate logistic regression, ROSE was a significant
predictor for better accuracy [OR 2.60 (95 % CI, 1.41 to 4.79); P = 0.002; β = 0.96].
Discussion
The pathological diagnosis of a solid pancreatic lesion is important to ensure adequate
management and optimize patient prognosis [11]
[13]
[21]. In this large, multi-center study, we compared EUS-FNA and EUS-FNB in many respects.
Despite allowing a higher number of cell-block evaluations, EUS-FNB was comparable
to EUS-FNA regarding accuracy, number of passes required for ROSE and cell-block evaluation,
and safety profile. The addition of ROSE to EUS-FNA provided better accuracy as compared
to EUS-FNA alone and EUS-FNB; however, sensitivity was not significantly different
and EUS-FNB alone possessed a better specificity. The addition of ROSE to EUS-FNB
provided even higher diagnostic yield suggesting that this may be helpful for select
cases and those with prior failed diagnosis on EUS-guided tissue sampling.
EUS-FNA of solid pancreatic lesions is a safe procedure, associated with high diagnostic
accuracy, usually above 85 %, and typically better when ROSE is available [6]
[7]
[8]. However, the diagnostic accuracy of EUS-FNA with cytology is insufficient to verify
cellular arrangement and tissue architecture. The limitation in achieving diagnosis
using EUS-FNA is the pauci-cellular nature of the aspirate with a significant proportion
of the collected tissue being distorted or consumed during automated processing and
sectioning [17]
[22]. Procurement of histological samples that yield an adequate amount of tissue suitable
for IHC staining is pivotal for personalized management of some lesions, such as metastatic
lesions or gastrointestinal stromal tumors (GIST), and other uncommon lesions [12]
[13]
[21]
[22]. In our study, cell-block analysis was possible in 80.41 % of patients after FNA
and in 93.42 % after FNB (P < 0.001). Our results are similar to a previous systematic review and meta-analysis
including eight randomized controlled trials (RCTs) that compared these techniques
[5].
In our study, technical success was reported in all patients, similar to several studies
evaluating FNB needles [3]
[14]
[23]
[24]. These results demonstrate that FNB can be easily performed in any location, unlike
from the first generation FNB device (Tru-cut) [25]. Additionally, to confirm this finding we performed a subgroup analysis based on
route of tissue sampling. We compared FNA and FNB performed via a transgastric and
transduodenal route and showed no difference in accuracy between the two needle types
[transgastric (FNA: 87.50 % versus FNB: 88.40 %; P = 0.831) and transduodenal (FNA: 86.36 % versus FNB: 91.85 %; P = 0.157)].
Most studies comparing FNA and FNB have demonstrated that these methods are comparable
in terms of diagnostic accuracy, AEs, and technical success. However, FNB typically
requires fewer needle passes to achieve adequate sampling for ROSE and cell-block
[3]
[5]
[24]
[26]
[27]. A lower number of passes may be translated into shorter procedure time, less risk
of adverse events, and more operational efficiency for both endoscopy and cytopathology
units. However, unlike most previous studies, in our analysis, the number of passes
required to achieve sample for ROSE (FNA: 3.04 ± 1.88, FNB: 3.06 ± 1.62) and cell-block
(FNA: 3.35 ± 2.02, FNB: 3.08 ± 1.63) were similar between both techniques (P > 0.05).
The difference between our results and other studies may be due to the fact that ROSE
is not widely used at all institutions included in this multi-center study. The fact
that ROSE did not result in a lower number of needle passes, may have contributed
to the overall higher tissue yield in the ROSE group. In our study, the majority of
cases were performed without ROSE. Similar to our study, Bang et al. also showed no
significant difference in mean number of passes required to establish a diagnosis
in a RCT [28]. Nevertheless, our study illustrated FNB enables the diagnostic yield of more than
90 % for cell-block assessment (FNA: 80.41 % vs FNB: 93.42 %, P < 0.001), showing that this technique may eliminate the need for ROSE.
Uniquely, in our study we compared both types of needles with and without ROSE. EUS-FNA
with ROSE presented similar sensitivity and lower specificity to EUS-FNB alone. Similar
to our results, a previous meta-analysis and additional retrospective study showed
that EUS-FNB without ROSE provides a similar diagnostic yield than EUS-FNA with ROSE
[7]
[29]. On subgroup analyses, we demonstrated that FNB with ROSE further increased the
diagnostic yield (FNB with ROSE: 93.13 % versus FNB alone: 80.72 %), suggesting this
may be useful in difficult cases, or in cases with failed diagnosis on prior EUS-tissue
sampling. A systematic review including 10 FNB with ROSE studies and 13 FNB without
ROSE studies did not show a significant difference between FNB with and without ROSE
[30]. Presence of tissue cores was 86 % in both groups. Mean sensitivity and specificity
were 96 % and 100 % for the FNB with ROSE groups versus 86.6 % and 100 % in the FNB
without ROSE group, respectively. Diagnostic adequacy and diagnostic accuracy were
86.5 % and 85.5 % for FNB with ROSE group versus 89,6 % and 86.1 % for FNB without
ROSE group. To better understand the need for ROSE in FNB samples, a multi-center
randomized non-inferiority trial is currently underway (FROSENOR) [31].
Unlike in most studies available in the literature, we analyzed the sensitivity, specificity,
+LR, –LR, PPV, NPV, and accuracy of EUS-FNA compared to EUS-FNB [3]
[14]
[23]
[28]
[32]. EUS-FNB had a better sensitivity (89.09 % versus 85.62 %), specificity (98.04 %
versus 89.55 %), and accuracy (90.29 % versus 87.50 %) when compared to EUS-FNA; however,
no statistical significance was found. Our results are similar to a prior RCT that
evaluated the sensitivity, specificity, and accuracy of EUS-FNA versus EUS-FNB [4]. The sensitivity, specificity, and accuracy of FNA and FNB was 98.2 %, 100 %, and
98.3 % for FNA and 94.6 %, 100 %, and 94.8 % for FNB. The similar diagnostic yield
between both techniques reported in our study is compatible with previous studies,
including a systematic review and meta-analysis based on 8 RCTs [5].
These results may be related to the fact that both procedures have a high accuracy
rate, and thus an even larger number of patients would be necessary to prove superiority
of FNB. After these results, in an attempt to prove that FNB may be superior to FNA,
a large randomized trial, including 408 patients, showed superiority favoring FNB.
However, this study included both pancreatic (n = 249 patients) and non-pancreatic
masses (n = 159 patients) [14]. Recently, another systematic review and meta-analysis [2] based on 11 relatively small randomized trials (three more studies than the previous
meta-analysis [5]) showed that FNB was superior to FNA in sampling pancreatic masses [2]. Due to these heterogeneous results, we believe that more studies including a larger
number of patients, such as our study are warranted to define the best modality in
sampling pancreatic lesions.
Studies diverge on consideration of an inconclusive (non-diagnostic) result as benign
or in exclude the result from the analysis. This fact is related to the heterogeneity
of the previously results published in the literature [4]
[6]
[14]. When excluding inconclusive results, an increase in accuracy is observed. In this
analysis we choose to be more rigorous and considered inconclusive results as benign
lesions. As expected from sampling diagnostic modalities, the specificity and PPV
were high in both techniques, showing that a positive result for a malignant lesion
is very reliable. However, in both groups the sensitivity and NPV were low, and thus
a negative result cannot exclude a neoplastic lesion. The +LR measures how well a
test diagnosis the lesion. The higher the +LR, the better the test performs in identifying
the precise diagnosis. The –LR of a test measures how well the test performs in excluding
the disease. The lower the LR-, the better the test performs in excluding a disease.
In our analysis, EUS-FNA and EUS-FNB showed similar +LR and –LR.
In our study, we also performed a multivariate analysis to find an association between
several variables, including age, gender, needle type, needle size, use of ROSE, and
cell block assessment on diagnostic accuracy. In our analysis, ROSE was the only independent
predictor for better accuracy with an OR of 2.60. Different from our study, in a multivariable
logistic regression of a series including both pancreatic and non-pancreatic solid
lesions, FNB and lesion size were associated with the need to perform only one pass
to achieve onsite diagnostic adequacy and were associated with procurement of diagnostically
adequate histological specimens for offsite assessment [22].
The safety of EUS-tissue sampling is well established and few AEs are encountered
in the literature. Severe adverse events are especially rare [6]
[23]
[28]
[33]. The safety profile of FNB was comparable to that of FNA, with only one AE encountered
in the entire cohort – though this resulted in the patient’s death. The AE occurred
after an FNB procedure for suspected neuroendocrine tumor with active acute pancreatitis,
which is a contraindication for the procedure. After the procedure, the patient clinically
deteriorated, and passed away. We believe that this AE was not directly related to
FNB as a technique, with any tissue sampling technique possessing the potential to
cause this AE. Therefore, we do not recommend EUS-tissue sampling in patients with
acute pancreatitis. No other AEs were reported. In the literature, several studies
showed no AEs related to EUS-FNA or EUS-FNB in the diagnosis of solid pancreatic lesions
[3]
[11]
[14].
Despite being the largest study to date to exclusively evaluate solid pancreatic lesions,
we recognize there are some limitations to our study. This was a retrospective study
with the inherent limitations expected with such a design, including potential selection
bias, lack of randomization, and loss-to-follow-up. Although none of the patients
with benign disease demonstrated disease progression at follow-up, we could not obtain
further tissue results for ethical concerns. In addition, we included different needles
sizes for FNA and FNB groups. However, a meta-analysis including just RCT did not
show significant difference between different needles sizes [8]. We did not evaluate the needles regarding the various types of pancreatic masses.
However, several studies have shown that FNB is associated with better results compared
to FNA in several types of pancreatic lesions. Elhanafi et al showed that FNB should
be considered when pancreatic adenocarcinoma genotyping is requested, especially for
tumors smaller than 3 cm located in the head/neck of the pancreas [34]. In a retrospective study including 91 patients over a 13-year period evaluating
FNA and FNB in neuroendocrine pancreatic tumors, FNB was found to improve diagnostic
sensitivity and conferred additional information to cytological assessment [35]. In a RCT evaluating FNB needles in the diagnosis of type 1 auto-immune pancreatitis
including 110 patients, the authors found that 36 patients could not be diagnosed
with type 1 auto-immune pancreatitis without FNB results [36]. Procedural costs were not compared between the two cohorts in our study. However,
recently a randomized trial showed that the strategy of EUS-FNB was cost saving compared
to EUS-FNA over a wide range of cost and outcome probabilities [30].
Conclusion
In summary, EUS-FNB allowed for more consistent cell-block evaluation as compared
to EUS-FNA, with similar number of passes required to achieve adequate sample. EUS-FNA
with ROSE was found to have a similar sensitivity to EUS-FNB alone. Therefore, the
similar sensitivity of EUS-FNA with ROSE compared to FNB alone suggests a reduced
need for ROSE as part of the standard algorithm of pancreatic sampling. While FNB
alone produced similar diagnostic findings to EUS-FNA with ROSE, FNB with ROSE still
was noted to increase diagnostic yield. This finding may favor a unique role for ROSE,
suggesting it may be useful in cases where previous EUS-guided sampling may have been
indeterminate.