Development and Validation of a Mobile Phone Application for Measuring Knee Range of Motion

Abstract
Knee range of motion (ROM) is an important indicator of knee function. Outside the clinical setting, patients may not be able to accurately assess knee ROM, which may impair recovery following trauma or surgery. This study aims to validate a smartphone mobile application developed to measure knee ROM compared to visual and goniometer ROM measurements. A knee ROM Android mobile application was developed to measure knee ROM. Patients ≥ 18 years old presenting to an orthopaedic clinic with native knee complaints were approached to participate. Knee ROM was measured bilaterally by an arthroplasty-trained surgeon using (1) vision, (2) goniometer, and (3) the mobile application. Measurements were compared in flexion and extension using a one-way analysis of variance with post hoc Tukey test (alpha = 0.05). Eighty-four knee ROM measurements (40 left, 44 right) were obtained in 47 patients. Median Kellgren–Lawrence grade from available radiographs was grade 3. In flexion, mobile application (117.6 ± 14.7 degrees) measurements were not significantly different from visual (116.1 ± 13.6 degrees) or goniometer (116.2 ± 13.6 degrees) measurements. In extension, mobile application (4.8 ± 7.3 degrees) measurements were significantly different from visual (1.9 ± 4.1 degrees) measurements on post hoc analysis (p < 0.01), while no differences were present compared to goniometer (3.1 ± 5.8 degrees) measurements. Our study found that a mobile application for evaluating knee ROM was noninferior to goniometer-based measurements performed by an arthroplasty-trained surgeon. Future studies will investigate this application's utility in (1) remote patient care, (2) accelerating recovery during rehabilitation, (3) detecting early postoperative complications including arthrofibrosis, and (4) adding additional functionalities to the application to provide more detail-oriented descriptive analyses of patient knee function.
Keywords
orthopaedic surgery - adult reconstruction - postoperative rehabilitation - technology - knee arthroplastyPublication History
Received: 27 November 2023
Accepted: 13 August 2024
Accepted Manuscript online:
14 August 2024
Article published online:
12 September 2024
© 2024. Thieme. All rights reserved.
Thieme Medical Publishers, Inc.
333 Seventh Avenue, 18th Floor, New York, NY 10001, USA
-
References
- 1 Roaas A, Andersson GBJ. Normal range of motion of the hip, knee and ankle joints in male subjects, 30-40 years of age. Acta Orthop Scand 1982; 53 (02) 205-208
- 2 Boone DC, Azen SP. Normal range of motion of joints in male subjects. J Bone Joint Surg Am 1979; 61 (05) 756-759
- 3 Ersoz M, Ergun S. Relationship between knee range of motion and Kellgren-Lawrence radiographic scores in knee osteoarthritis. Am J Phys Med Rehabil 2003; 82 (02) 110-115
- 4 Barrow AE, Sheean AJ, Burns TC. Return to duty following combat-related multi-ligamentous knee injury. Injury 2017; 48 (04) 861-865
- 5 Christiano AV, Pean CA, Kugelman DN, Konda SR, Egol KA. Function and knee range of motion plateau six months following lateral tibial plateau fractures. J Knee Surg 2020; 33 (05) 481-485
- 6 Danziger MB, Caucci D, Zecher SB, Segal D, Covall DJ. Treatment of intercondylar and supracondylar distal femur fractures using the GSH supracondylar nail. Am J Orthop 1995; 24 (09) 684-690
- 7 Oka T, Wada O, Asai T, Maruno H, Mizuno K. Importance of knee flexion range of motion during the acute phase after total knee arthroplasty. Phys Ther Res 2020; 23 (02) 143-148
- 8 Olsen AA, Nin DZ, Chen YW. et al. The cost of stiffness after total knee arthroplasty. J Arthroplasty 2023; 38 (04) 638-643
- 9 Rodríguez-Merchán EC. The stiff total knee arthroplasty: causes, treatment modalities and results. EFORT Open Rev 2019; 4 (10) 602-610
- 10 Carter TI, Pansy B, Wolff AL. et al. Accuracy and reliability of three different techniques for manual goniometry for wrist motion: a cadaveric study. J Hand Surg Am 2009; 34 (08) 1422-1428
- 11 Hancock GE, Hepworth T, Wembridge K. Accuracy and reliability of knee goniometry methods. J Exp Orthop 2018; 5 (01) 46
- 12 Terwee CB, de Winter AF, Scholten RJ. et al. Interobserver reproducibility of the visual estimation of range of motion of the shoulder. Arch Phys Med Rehabil 2005; 86 (07) 1356-1361
- 13 Testa EJ, Gil JA, Lakomkin N, Hansen H, Cruz AI. Visual joint angle assessment: does accuracy improve with a higher level of orthopaedic surgery training?. R I Med J (2013) 2022; 105 (08) 53-56
- 14 Woerner M, Weber M, Sendtner E. et al. Visual intraoperative estimation of range of motion is misleading in minimally invasive total hip arthroplasty. Arch Orthop Trauma Surg 2016; 136 (07) 1015-1020
- 15 Draper CE, Chew KTL, Wang R, Jennings F, Gold GE, Fredericson M. Comparison of quadriceps angle measurements using short-arm and long-arm goniometers: correlation with MRI. PM R 2011; 3 (02) 111-116
- 16 Alam MS, Morshidi MA, Gunawan TS, Olanrewaju RF, Arifin F. Pose estimation algorithm for mobile augmented reality based on inertial sensor fusion. Int J Electr Comput Eng IJECE. 2022; 12 (04) 3620
- 17 Sardar AW, Ullah F, Bacha J, Khan J, Ali F, Lee S. Mobile sensors based platform of Human Physical Activities Recognition for COVID-19 spread minimization. Comput Biol Med 2022; 146: 105662
- 18 Pires IM, Garcia NM, Zdravevski E, Lameski P. Daily motionless activities: a dataset with accelerometer, magnetometer, gyroscope, environment, and GPS data. Sci Data 2022; 9 (01) 105
- 19 Miyachi Y, Ito M, Furuta K, Ban R, Hanamura S, Kamiya M. Reliability and validity of lower limb joint range of motion measurements using a smartphone. Nagoya J Med Sci 2022; 84 (01) 7-18
- 20 Şengül G, Ozcelik E, Misra S, Damaševičius R, Maskeliūnas R. Fusion of smartphone sensor data for classification of daily user activities. Multimedia Tools Appl 2021; 80 (24) 33527-33546
- 21 Estrada JE, Vea LA. Real-time human sitting posture detection using mobile devices. In: 2016 IEEE Region 10 Symposium (TENSYMP) [Internet]. Bali, Indonesia: IEEE; 2016: 140-144 . Accessed June 22, 2023 at: http://ieeexplore.ieee.org/document/7519393/
- 22 Khan YA, Imaduddin S, Prabhat R, Wajid M. Classification of Human Motion Activities using Mobile Phone Sensors and Deep Learning Model. In: 2022 8th International Conference on Advanced Computing and Communication Systems (ICACCS) [Internet]. Coimbatore, India: IEEE; 2022: 1381-1386 . Accessed June 22, 2023 at: https://ieeexplore.ieee.org/document/9785009/
- 23 Fuentes AT, Kipfmüller M, Burghart C. et al. Stable operation of arm type robots on mobile platforms. Procedia CIRP 2021; 99: 104-109
- 24 Li L, Foo MJ, Chen J. et al. Mobile Robotic Balance Assistant (MRBA): a gait assistive and fall intervention robot for daily living. J Neuroeng Rehabil 2023; 20 (01) 29
- 25 Elgueta-Cancino E, Rice K, Abichandani D, Falla D. Measurement properties of smartphone applications for the measurement of neck range of motion: a systematic review and meta analyses. BMC Musculoskelet Disord 2022; 23 (01) 138
- 26 Nuhmani S, Khan MH, Kachanathu SJ, Bari MA, Abualait TS, Muaidi QI. Reliability and validity of smartphone applications to measure the spinal range of motion: a systematic review. Expert Rev Med Devices 2021; 18 (09) 893-901
- 27 Ravi B, Kapoor M, Player D. Feasibility and reliability of a web-based smartphone application for joint position measurement. J Rehabil Med 2021; 53 (05) jrm00188
- 28 Sarac DC, Yalcinkaya G, Unver B. Validity and reliability of a smartphone goniometer application for measuring hip range of motions. Work 2022; 71 (01) 275-280
- 29 Dos Santos RA, Derhon V, Brandalize M, Brandalize D, Rossi LP. Evaluation of knee range of motion: correlation between measurements using a universal goniometer and a smartphone goniometric application. J Bodyw Mov Ther 2017; 21 (03) 699-703
- 30 Bong MR, Di Cesare PE. Stiffness after total knee arthroplasty. J Am Acad Orthop Surg 2004; 12 (03) 164-171
- 31 Zhou Z, Yew KSA, Arul E. et al. Recovery in knee range of motion reaches a plateau by 12 months after total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 2015; 23 (06) 1729-1733
- 32 Issa K, Banerjee S, Kester MA, Khanuja HS, Delanois RE, Mont MA. The effect of timing of manipulation under anesthesia to improve range of motion and functional outcomes following total knee arthroplasty. J Bone Joint Surg Am 2014; 96 (16) 1349-1357
- 33 Shoji H, Solomonow M, Yoshino S, D'Ambrosia R, Dabezies E. Factors affecting postoperative flexion in total knee arthroplasty. Orthopedics 1990; 13 (06) 643-649