Horm Metab Res 2011; 43(6): 422-426
DOI: 10.1055/s-0031-1275326
Humans, Clinical

© Georg Thieme Verlag KG Stuttgart · New York

Reference Ranges for Analytes of Thyroid Function in Children

F. A. Verburg1 , C. Kirchgässner1 , H. Hebestreit2 , U. Steigerwald3 , E. G. W. M. Lentjes4 , K. Ergezinger2 , I. Grelle1 , C. Reiners1 , M. Luster1 , 5
  • 1Department of Nuclear Medicine, University of Würzburg, Würzburg, Germany
  • 2Department of Pediatrics, University of Würzburg, Würzburg, Germany
  • 3Department of Clinical Biochemistry, University of Würzburg, Würzburg, Germany
  • 4Department of Clinical Chemistry & Hematology, University Medical Center Utrecht, Utrecht, The Netherlands
  • 5Department of Nuclear Medicine, University of Ulm, Ulm, Germany
Further Information

Publication History

received 04.08.2010

accepted 10.03.2011

Publication Date:
11 April 2011 (online)

Abstract

Promptly detecting pediatric thyroid dysfunction requires age-appropriate reference ranges for serum thyroid-stimulating hormone (TSH), serum free thyroxine (FT4), and serum free triiodothyronine (FT3). We sought to establish such ranges, employing the widely-used Immulite® 2000 automated immunoluminometric assays in a large population. We assayed the analytes according to manufacturer's instructions in serum samples from 359 male and 297 female university hospital patients, aged between newborn to 18 years, without evidence of thyroid or pituitary dysfunction. As data were not normally distributed, the reference ranges were assumed to lie between the 2.5th and 97.5th percentiles. Curves for age-related changes in the reference ranges were calculated using the linearity, median and skewness method. TSH, FT4, and FT3 reference ranges showed a wide spread immediately after birth, rapidly decreasing within the first 2 years of life. Reference range width was fairly stable after about age 4 years. However, from that time, the ranges’ lower and upper limits steadily declined, essentially reaching (FT3) or approximating (TSH, FT4) healthy adult values by age 18 years. Age-specific reference ranges should be used when measuring TSH, FT4, and FT3 in children. During very early life, values of these analytes range widely, making it challenging to interpret measurements in infants, and, especially, newborns.

References

  • 1 Mitchell ML, Larson CA. Neonatal screening for thyroid disease. In: Braverman LE (ed).Diseases of the thyroid Totowa, NJ: Humana Press Inc.; 2003: 53-62
  • 2 Soldin OP, Jang M, Guo T, Soldin SJ. Pediatric reference intervals for free thyroxine and free triiodothyronine.  Thyroid. 2009;  19 699-702
  • 3 Soldin SJ, Morales A, Albalos F, Lenherr S, Rifai N. Pediatric reference ranges on the Abbott IMx for FSH, LH, prolactin, TSH, T4, T3, free T4, free T3, T-uptake, IgE, and ferritin.  Clin Biochem. 1995;  28 603-606
  • 4 Soldin SJ, Cheng LL, Lam LY, Werner A, Le AD, Soldin OP. Comparison of FT4 with log TSH on the Abbott Architect ci8200: Pediatric reference intervals for free thyroxine and thyroid-stimulating hormone.  Clin Chim Acta. 2010;  411 250-252
  • 5 Elmlinger MW, Kuhnel W, Lambrecht HG, Ranke MB. Reference intervals from birth to adulthood for serum thyroxine (T4), triiodothyronine (T3), free T3, free T4, thyroxine binding globulin (TBG) and thyrotropin (TSH).  Clin Chem Lab Med. 2001;  39 973-979
  • 6 Kapelari K, Kirchlechner C, Hogler W, Schweitzer K, Virgolini I, Moncayo R. Pediatric reference intervals for thyroid hormone levels from birth to adulthood: a retrospective study.  BMC Endocr Disord. 2008;  8 15
  • 7 Hubner U, Englisch C, Werkmann H, Butz H, Georgs T, Zabransky S, Herrmann W. Continuous age-dependent reference ranges for thyroid hormones in neonates, infants, children and adolescents established using the ADVIA Centaur Analyzer.  Clin Chem Lab Med. 2002;  40 1040-1047
  • 8 Zurakowski D, Di Canzio J, Majzoub JA. Pediatric reference intervals for serum thyroxine, triiodothyronine, thyrotropin, and free thyroxine.  Clin Chem. 1999;  45 1087-1091
  • 9 Clark SJ, Deming DD, Emery JR, Adams LM, Carlton EI, Nelson JC. Reference ranges for thyroid function tests in premature infants beyond the first week of life.  J Perinatol. 2001;  21 531-536
  • 10 Costongs GM, van Oers RJ, Leerkes B, Janson PC. Evaluation of the DPC IMMULITE random access immunoassay analyser.  Eur J Clin Chem Clin Biochem. 1995;  33 887-892
  • 11 Cole TJ, Green PJ. Smoothing reference centile curves: the LMS method and penalized likelihood.  Stat Med. 1992;  11 1305-1319
  • 12 Solberg HE. International Federation of Clinical Chemistry (IFCC), Scientific Committee, Clinical Section, Expert Panel on Theory of Reference Values, and International Committee for Standardization in Haematology (ICSH), Standing Committee on Reference Values. Approved Recommendation (1986) on the theory of reference values. Part 1. The concept of reference values.  J Clin Chem Clin Biochem. 1987;  25 337-342
  • 13 Laboratory medicine practice guidelines: .laboratory support for the diagnosis and monitoring of thyroid disease. Washington: National Academy of Clinical Biochemistry; 2002
  • 14 Brown RS. Thyroid disease in infancy, childhood and adolescence. In: Braverman LE (ed).Diseases of the thyroid Totowa, NJ: Humana Press Inc.; 2003: 63-84
  • 15 Volzke H, Schmidt CO, John U, Wallaschofski H, Dorr M, Nauck M. Reference levels for serum thyroid function tests of diagnostic and prognostic significance.  Horm Metab Res. 2010;  42 809-814

Correspondence

F. A. VerburgMD, PhD 

University Hospital Aachen

Department of Nuclear

Medicine

Pauwelsstraße 30

52074 Aachen

Germany

Phone: +49/241/80 36619

Fax: +49/241/80 82520

Email: fverburg@ukaachen.de

    >